Catalog excerpts
Control & Monitoring Systems Compliances: FAA AC 150/5345-56: L-890 (Pending) ICAO Annex 14, Vol. 1 ICAO Aerodrome Design Manuel, Part 5 Transport Canada Aerodrome Standards The PRO command ALCMS is offered with the following monitioring options: ■ Control Only ■ Basic Monitoring ■ Advanced Monitoing The ALCMS has the following fail-safe options ■ Preset State ■ Last State Features ■ Flexible and expandable system design ■ Touchscreen Control ■ Custom graphics that reflect airport layout and user needs ■ Real-time monitoring of system with event alarms ■ Event Recording for system and circuit analysis ■ Intuitive user interface allows for operating system with ease ■ Ability to input users and lock screen/ transfer control when necessary ■ Full system redundancy available ■ Fail Safe Feature of Last state or Pre-set state available ■ Vault configuration screen for CCR and circuit changes ■ CCR configuration screen ■ Photo-cell control is available ■ Compact system design allows for more room in the vault ■ Easy to install with straightforward system layout and few wiring requirements ■ Off-the-self reliable Eaton PLC hardware Home Office: United States - +1 860-683-4300 International Offices: Canada • China • Dubai • Mexico • Brazil Eaton Crouse-Hinds provides an airfield monitoring and control system (ALCMS) using a Eaton Programmable Logic Controller (PLC). This system was designed with the small to medium airfield or GA Airport in mind. The PLC-ALCMS is designed to provide control and monitoring of constant current regulators and general airfield elements. Eaton Crouse-Hinds works with customers to provide an ease of doing business that results in a reliable and long lasting system for the airport. System Layout Example:
Open the catalog to page 1Cetification: 890G1 = L-890, PLC ALCMS Gen 1 Failsafe Options: A = Pre-Set B = Last - State (Latching) Control Options: A = Control Only B = Basic Monitoring C = Advanced Monitoring Potential Transformers* Number of PTs Needed: CCR > 20 kW, 6.6A CCR > 20 kW, 20A CCR < 20 kW, 6.6A CCR < 20 kW, 20A Airport Code: Project Number: - *If you have a Crouse-Hinds CCR you may already have the PT installed inside the regulator Failsafe Options: Type A - Preset - Upon a failsafe condition, the ALCMS controlled devices will switch to a pre-defined state (ON to a pre-defined rightness level, or...
Open the catalog to page 2Control & Monitoring Systems PRO Command PLC Enclosures: The PRO Command ALCMS system will be comprised of different locations each with there own control areas and enclosure cabinets to ensure control/ monitoring access and capabilities from all desired airport locations. The following are the ordering and part number explainations that will be used to customize the system to the airports needs. Please contract a Crouse-Hinds Sales or Customer Service Representative for help with ordering. HMI (Human Machine Interface) Touchscreen and Enclosure Ordering: Touchscreen Type: PH1 = HMI and PLC...
Open the catalog to page 3PRO Command PLC Enclosures: The PRO Command ALCMS system will be comprised of different locations each with there own control areas and enclosure cabinets to ensure control/ monitoring access and capabilities from all desired airport locations. The following are the ordering and part number explainations that will be used to customize the system to the airports needs. Please contract a Crouse-Hinds Sales or Customer Service Representative for help with ordering. General Elements Enclosure Ordering: P Touchscreen Type: PGE1 = PLC General Element Enclosure Gen 1 Screen Size: A = None B = 12”...
Open the catalog to page 4Control & Monitoring Systems Vault Enclosure Ordering: Touchscreen Type: PV1 = PLC Vault Enclosure Gen 1 Screen Size: A = 8.4” Touchscreen B = 5.7” Touchscreen Number of CCRs*: Insert Qty above Number of 3 or Less Brightness Step CCRs without Circuit Selector Switches: Insert Qty above Total Number of General Element and Selector Switch Pole Inputs**: Insert Qty above (Up to 32 Inputs) Number of General Elements to be Controlled**: Insert Qty above (Up to 8 elements) Enclosure: A = 24” x 24” Nema 12 Enclosure B = 36” x 36” Nema 12 Enclosure (Required for units with > 8 CCRs) Feedback Type:...
Open the catalog to page 5Vault Enclosure Outline Examples of Touchscreen Graphic Layouts DIM"B" REF ENCLOSURE SIZE
Open the catalog to page 6All EATON CROUSE-HINDS catalogs and technical brochures
-
IAL Inset Approach Light
3 Pages
-
PRO III TCL
2 Pages
-
PRO APF MIRL
2 Pages
-
IALE Inset Approach light
3 Pages
-
PRO III TOL
2 Pages
-
PRO III SBGL
2 Pages
-
PRO III IRGL/ISBL
2 Pages
-
SBL Elevated Stop Bar Light
2 Pages
-
ERL Elevated Runway Light
2 Pages
-
PRO APF AGS
16 Pages
-
AGS-LED
4 Pages
-
AGSF-LED Sign (L)
4 Pages
-
REIL-LED
1 Pages
-
EAL Elevated Approach Light
3 Pages
-
ALSF Flasher System
2 Pages
-
AV07
2 Pages
-
AV-LC
1 Pages
-
PRO APF Utility LED
2 Pages
-
UEL - UTILITY LED
2 Pages
-
W-Series Junction Boxes
9 Pages
-
Enclosure Accessories - Hubs
1 Pages
-
TCH Electric Clocks
1 Pages