RPS/DPS8000H Hydrogen Pressure Sensor
8Pages

{{requestButtons}}

Catalog excerpts

RPS/DPS8000H Hydrogen Pressure Sensor - 1

Hydrogen Focused High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace, oil and gas, and research environments. Today, Druck is part of Baker Hughes and has continually worked to develop and improve on the performance of our pressure sensors to meet our customers’ requirements. The RPS/DPS8000H combines ground-breaking TERPS technology and a hydrogen barrier coating to create the most accurate and stable hydrogen-capable pressure sensor on the market today. TERPS is a resonant silicon pressure sensor technology platform that provides an order of magnitude greater accuracy and stability than current pressure measurement technologies. TERPS technology also extends the pressure range capability to high pressures and, by incorporating true pressure media isolation, greatly improves its suitability for use in harsh environments. • Media isolated construction, suitable for use in harsh environments Challenges in hydrogen pressure measurement As a market leader in pressure measurement for the past 50 years, Druck is fully aware of the challenges that hydrogen applications pose for pressure sensors due to the unique behaviour of the medium. Exposure to hydrogen gas can impact the performance of a pressure sensor, specifically via the processes of hydrogen permeation and embrittlement, hence key design aspects need to be considered with a hydrogen pressure sensor to maintain accuracy and stability. In addition to providing the performance and packaging improvements available with TERPS, the RPS/DPS8000 product line takes advantage of best practices to offer a wide range of pressure and electrical connections to enable a level of customization for your specific requirements never before available in the performance class of this sensor. The combination of the power of the TERPS technology and the quality, reliability and flexibility of the RPS/DPS8000H Series offers a truly unique solution for high accuracy and high stability pressure measurement in a hydrogen-rich media. • High Precision, ±0.01% FS over compensated temperature range • High Stability, ±100 ppm FS/year • Wide temperature range, up to -40°C to +125°C (-40° to 257°F) • Suitable for use in hydrogen rich media • Multiple Output configurations, RS-232, RS-485, USB 2.0, CAN Bus, Frequency & Diode (TTL) • Wide selection of pressure & electrical connections to suit sp

Open the catalog to page 1
RPS/DPS8000H Hydrogen Pressure Sensor - 2

Response Time < 300 msec for pressure change from 10% to 90% FS Supply Response Base Pressure Ranges TTL: Accurate to specification within 500 ms of power up, over all operating temperatures RS232/RS485/CAN Bus/USB: Accurate to specification within 10 min of power-up Electrical Protection • 0 to 35 bar (0 to 507 psi) absolute • 0 to 70 bar (0 to 1015 psi) absolute • 0 to 100 bar (0 to 1450 psi) absolute • 0 to 200 bar (0 to 2900 psi) absolute Calibrated Ranges Any zero-based range between 2 and 200 bar (29 to 2900 psi) can be specified. (Performance will be of the full scale of the base...

Open the catalog to page 2
RPS/DPS8000H Hydrogen Pressure Sensor - 3

Physical Specifications Storage Temperature Range As compensated temperature range. Operating Temperature Range As compensated temperature range. Pressure Media Fluids compatible with 316L stainless steel and gold. Do not use with oxygen rich media or other strong oxidizing agents. This product contains materials or fluids that may degrade or combust in the presence of strong oxidizing agents. Other pressure connectors may be available. Contact Baker Hughes to discuss your requirement. Please ensure that only the intended sealing face is used when mounting the sensor. Failure to comply with...

Open the catalog to page 3
RPS/DPS8000H Hydrogen Pressure Sensor - 4

Connection Details Option Flying Leads Frequency & Diode Function Frequency & Diode Frequency & Diode Frequency & Diode – Frequency & Diode Function Frequency & Diode Frequency & Diode

Open the catalog to page 4
RPS/DPS8000H Hydrogen Pressure Sensor - 5

Supply: 9 TO 20 Output: **** Temp. Range: * MALE PRESSURE CONNECTION Ø 25 (0.98) CRIMP & BOOT PU CABLE IP65 Supply: 9 TO 20 Output: **** Temp. Range: * CONDUIT WITH POLYURETHANE CABLE 15 TYP (0.53) Ø 25 (0.98) OPTIONAL WELDED PRESSURE ADAPTOR Notes: 1. All dimensions are nominal lengths and are subject to change. 2. All dimensions are in millimeters (inches). 3. Other pressure and electrical connectors may be available, please contact Dr

Open the catalog to page 5
RPS/DPS8000H Hydrogen Pressure Sensor - 6

Ordering Information (1) Select model code Main Product Variant RPS Resonant Pressure Sensor - Frequency & Diode Output (Note 1) DPS Digital Pressure Sensor - Digital Output (Note 1) Diameter, Material and Isolation 80 25mm Stainless Steel Oil isolated Electrical Connector 0 No Electrical Connector (Flying leads length >100mm) 1 Polyurethane Cable IP65 2 Raychem Cable 6 MIL-C-26482 (6-pin Shell Size 10) C 1/2” NPT Conduit with Polyurethane Cable (Non-Exd Only) G M12x1 5-Pin H Orange PTFE Cable M Micro USB socket (Note 3) Output Option (Note 6) 1 Frequency & Diode (TTL) A RS485 B RS232 C CAN...

Open the catalog to page 6
RPS/DPS8000H Hydrogen Pressure Sensor - 7

Ordering Information (cont.) 2) State pressure range and units (e.g., 0 to 20 bar, 0 to 100 psi): Unit options are: Symbol pounds/sq. inch metres water inches water feet water inches mercury 3) State cable lengths and units e.g., 1 m cable, 3 ft cable (only required on certain electrical connectors): Note 6: Maximum Cable length: (1) Frequency & Diode – 10 m, (A) RS485 – 1000 m, (B) RS232 – 10 m, (C) CAN Bus – 1000 m. Integer values only, e.g. 1m (3 ft) cable. Minimum cable length is 1m (3 ft) if cable is supplied. Typical order examples: RPS 8011H-TA-A1-CC-H0-PA, 0-7 bara, 5 m cable DPS...

Open the catalog to page 7
RPS/DPS8000H Hydrogen Pressure Sensor - 8

© Copyright 2023. Baker Hughes Company. This material contains one or more registered trademark of Baker Hughes Company and its subsidiaries in one or more countries. All third-party product and company names are trademarks of their respective holders. 920-713B BHCS39429

Open the catalog to page 8

All Druck catalogs and technical brochures

  1. DPI 705E

    10 Pages

  2. DPS5000 I2C

    5 Pages

  3. ADTS 405 Mkll

    10 Pages

  4. ADTS542F

    6 Pages