The PDCR 1800 transducer (mV output) and the PTX 1800 transmitter (4 to 20 mA output) are the latest generation of fully submersible titanium high performance sensors for measurement of hydrostatic liquid levels. • Accuracy ±0.10% full scale (FS) best straight line (BSL) • Fully welded 17.5 mm diameter titanium construction • Polyurethane and hydrocarbon resistant cables • Full range of installation accessories The 1800 Series incorporates many enhanced features gained from experience in supplying thousands of sensors for small and large scale installations worldwide. Example applications include: • Potable water From ground water borehole to surface water level measurements in rivers, canals and reservoirs. • Waste water and remediation Monitoring of secondary and outflow sewage levels and contaminated ground water levels in land fill sites. • Tank level From land based liquid storage vessels to on-board ship ballast tank monitoring. • Sea water Marine environmental applications, including tide gauging, coastal flood protection and wave profiling, amongst others.
Open the catalog to page 1The combination of a high technology sensor, together with advanced signal conditioning and packaging techniques, provides an ideal long term solution for reliable, accurate and economical level measurements. The micromachined silicon element is sealed within an all-titanium pressure module assembly, fully isolated from the pressure media. This is contained in a slimline, welded titanium body, terminated in an injection moulded cable assembly. The cable features a Kevlar® strain cord and is IP68 rated for indefinite immersion in 700 mH2O, with a selection of cable materials to meet the application....
Open the catalog to page 2Excitation voltage PDCR 1800 (mV) Output is ratiometric to supply within 2.5 V to 12 V limits. The minimum supply voltage (VMIN) which must appear across the pressure transmitter terminals is 9 V and is given by the following equation: VMIN = VSUP - (0.02 x RLOOP) Where VSUP is supply voltage in Volts, and RLOOP is total loop resistance in Ohms Recommended power-on time before output sample: Combined effects of non-linearity, hysteresis and repeatability: • Option D: ±0.06% FS BSL maximum (±0.08% FS BSL max. for 1 mH2O and below) (240 mm with Lightning Surge Arrestor) M14 x 1.5 exposed thread...
Open the catalog to page 3Compensated temperature range -2 to 30°C (28 to 86°F) Temperature effects • ±0.3% FS Temperature Error Band (TEB) for 3.5 mH2O range and above • ±0.6% FS TEB for ranges below 3.5 mH2O Physical specification Lightning Surge Arrestor (Option for PTX versions only): Integral lightning protection assembly certified to Standard IEC 61000-4-5 (Level 4) Pressure connection (Option C) Standard: Radial holed M14 x 1.5 mm male thread fitted with protective acetyl nose cone Option C: Screw on welded pressure connection • Category 10 min. Figure 514.4-16 • Product will withstand 20 g peak shock half sine...
Open the catalog to page 4A full range of accessories is available to enhance installation, operation and maintenance of the 1800 Series as listed below: • STE moisture proof sensor termination enclosure (202-034-05) • Slimline sink weight 017.5 mm (DA2608-1-01) • Short sink weight 025 mm (DA4068-1-01) • Cable clamp system (192-373-01) • 360° Rotatable calibration adapter to: • Economical direct calibration adapter to: • Accessory pack contains (S01830E) STE box, Slimline sink weight, cable clamp, direct calibration adapter (b) Intrinsically Safe Version (B1) FM US Intrinsically Safe Version (c) Alternative Pressure Connection...
Open the catalog to page 56 Pages
17 Pages
7 Pages
6 Pages
8 Pages