PDCR 1800 transducer (mV output) and PTX 1800 transmitter (4 to 20 mA output) - 1800 series
4Pages

{{requestButtons}}

Catalog excerpts

PDCR 1800 transducer (mV output) and PTX 1800 transmitter (4 to 20 mA output) - 1800 series - 1

Druck high performance level pressure sensors The PDCR 1800 transducer (mV output) and the PTX 1800 transmitter (4 to 20 mA output) are the latest generation of fully submersible titanium high performance sensors for measurement of hydrostatic liquid levels. • Ranges from 0.75 mH2O to 600 mH2O • Accuracy ±0.10% full scale (FS) best straight line (BSL) • Fully welded 17.5 mm diameter titanium construction • Polyurethane and hydrocarbon resistant cables • Full range of installation accessories The 1800 Series incorporates many enhanced features gained from experience in supplying thousands of sensors for small and large scale installations worldwide. Example applications include: • Potable water From ground water borehole to surface water level measurements in rivers, canals and reservoirs. • Waste water and remediation Monitoring of secondary and outflow sewage levels and contaminated ground water levels in land fill sites. • Tank level From land based liquid storage vessels to on-board ship ballast tank monitoring. • Sea water Marine environmental applications, including tide gauging, coastal flood protection and wave profiling,

Open the catalog to page 1
PDCR 1800 transducer (mV output) and PTX 1800 transmitter (4 to 20 mA output) - 1800 series - 2

Reliability and data quality The combination of a high technology sensor, together with advanced signal conditioning and packaging techniques, provides an ideal long term solution for reliable, accurate and economical level measurements. The micromachined silicon element is sealed within an all-titanium pressure module assembly, fully isolated from the pressure media. This is contained in a slimline, welded titanium body, terminated in an injection moulded cable assembly. The cable features a Kevlar® strain cord and is IP68 rated for indefinite immersion in 700 mH2O, with a selection of...

Open the catalog to page 2
PDCR 1800 transducer (mV output) and PTX 1800 transmitter (4 to 20 mA output) - 1800 series - 3

1800 series specifications Excitation voltage PDCR 1800 (mV) 10 V at 5 mA nominal Ø17.5 mm M14 x 1.5 exposed thread with nose cone removed Output is ratiometric to supply within 2.5 V to 12 V limits. 185 mm approx. (242 mm with Lightning Surge Arrestor) The minimum supply voltage (VMIN) which must appear across the pressure transmitter terminals is 9 V and is given by the following equation: VMIN = VSUP - (0.02 x RLOOP) Where VSUP is supply voltage in Volts, and RLOOP is total loop resistance in Ohms Pulse power excitation Recommended power-on time before output sample: • PDCR 1800: 10 ms •...

Open the catalog to page 3
PDCR 1800 transducer (mV output) and PTX 1800 transmitter (4 to 20 mA output) - 1800 series - 4

1800 series specifications Intrinsic safety (Option B) PDCR 1800: ATEX Certified (BAS02ATEX1250X) for use with IS barrier systems to EEx ia IIC T4 (-40°C ≤ Ta ≤ 80°C) for cable lengths up to 29 metres PTX 1800: ATEX and IECEx Certified (BAS01ATEX1018X and IECEx BAS10.0077X) for use with IS barrier systems to Ex ia I Ma (40°C ≤ Ta ≤ +80°C) and Ex ia IIC T4 Ga (-40°C ≤ Ta ≤ +80°C) for cable lengths up to 300 metres Lightning Surge Arrestor (PTX versions only): Integral lightning protection assembly certified to Standard IEC 61000-4-5 (Level 4) Physical specification Pressure connection...

Open the catalog to page 4