The DPI610E handheld pressure calibrator is the latest and the sixth generation of the DPI600 family. The DPI610E combines effortless pressure measurement and generation, signal measurement and loop power with significantly improved pump capabilities and a powerful touch and button user interface. With a robust design, the unit has been engineered for instrument technicians, using input from those working in the field. It is an ideal solution to your test and calibration application. • The complete pressure calibration tool provides pressure: - Vacuum to 35 bar/500 psi/3.5 MPa pneumatic pressures with inbuilt barometer for accurate pseudo pressure measurements • HART as standard on all versions • Best in class pressure accuracy: Total 1 year uncertainty down to 0.025% full scale (FS) over temperature range of -10°C to +50°C • Integral calibration record with calibration due countdown • Robust, handheld design with backlit high-contrast display • Hazardous area (Intrinsically safe) version available • Optional remote plug and play pressure sensor (PM700E) and Resistance Temperature Detector (RTD-INTERFACE) • Minimize in-the-field leaks with quick-fit pressure adapters and hoses • Full data logging and local documenting capabilities included • Provided with one free 4Sight2 Lite calibration software license
Open the catalog to page 1DPI610E hand-held pressure calibrator The DPI610E is the sixth generation in the DPI600 family, which was first introduced in 1984. The DPI600 family revolutionized test and calibration by providing all the tools for pressure generation and signal measurement in self contained portable packages. The DPI600 soon became the industry workhorse and today it is simply known as the “Druck.” Building on the technical legacy and more than three decades of experience in pressure measurement and calibration, the DPI610E provides all the convenience and reliability of a true “Druck”, yet offers faster performance...
Open the catalog to page 2Pressure generation The innovative design of the DPI610E pressure generation system provides significantly easier and more efficient pressure generation and precise control using carefully selected components. With the improved pressure generation capabilities, the DPI610E provides higher pressures and higher volume handling with market leading pneumatic pressures from 95% vacuum to 35 bar/500 psi/3.5 MPa. A simple selector lets you switch from vacuum to pressure and with a few stokes of the pump, you can generate the required pressure. Fine adjustment can be made with the built-in volume adjuster...
Open the catalog to page 3Hazardous area pneumatic unit shown Carry strap Power charging socket Pressure vent valve (precision needle valve for fine control) Quick-fit pressure adapter system (no tools or seals required) Electrical connections for measuring /sourcing mA, mV, V and detecting switch contacts 10V DC regulated supply and 24V loop power Battery indicator strip On/Off Home Push button interface (for gloved use) External pressure or temperature sensor port Navigation keypad Protective over molding Vacuum / pressure selector Volume adjuster for precise pressure setting Anti-slip feet (front and rear)
Open the catalog to page 4Brand new User Interface The DPI610E user interface can be fully driven from either the touchscreen or via push buttons to allow use with or without gloves. • The DASHBOARD allows quick application selection without the need for menus or special keys. • The TASK menu provides a library of popular configurations. From the dashboard screen three clicks completely reconfigure the DPI610E for the next job. • From the FAVORITES menu it's even quicker to access regularly used and customized TASKS. • Electrical connection diagrams can be viewed on screen 2. Touch to a TASK to make a selection Multiple...
Open the catalog to page 5Current Source Automation (mA Output): Simply configured for simulating transmitter outputs into control loops, testing valve positioners and checking safety systems. The source function has programmable end points, with manual or automatic sequencing. The following options are available for quick set-up: • % step: The step size is defined as a percentage between two end points. For example, 25% between 4 and 20 mA provides five test points of 4, 8, 12, 16 and 20 mA. Help: The DPI610E is provided with a multi-lingual quick user guide to get you up and running without delay. For convenience, the...
Open the catalog to page 6Measurement Resolution Pressure Resolution: Adjustable from four to seven digits; this matches the displayed value to that of the test device for easy comparison. Electrical Resolution: voltage measurement is adjustable from four to seven digits, current measurement and sourcing from four to six digits. 0 to 100% FS temporary zero offset capability by subtracting the current reading from subsequent measurements. Can be applied to all measurement types. Enables a filtered reading by showing a rolling average of the last 10 measurements. Provides a more stable reading in a noisy measurement. Can...
Open the catalog to page 7PASS/FAIL error analysis The DPI610E is a simple-to-use “everyday” tool for maintaining and calibrating pressure instruments. It has a documenting application, providing advanced features for automating calibration procedures, calculating errors and interfacing with PCs and calibration and maintenance systems. Error analysis calculates the error of the device being tested and reports a pass or fail. The error is displayed live allowing zero and span adjustments to be assessed as they are made. Automated calibration procedures Multi-channel data logging Test procedures can be created using the...
Open the catalog to page 8Ordering information Please use the following part numbers when ordering: Model type Pneumatic safe area Hydraulic safe area Pneumatic hazardous area Hydraulic hazardous area Pressure range code and reference type (Gauge or Absolute); (Mandatory to select only one e.g. 16G for each configuration) Pressure range code Pressure units U0 All pressure units (Default selection) U1 Pa (Si) pressure units only Country of use (entered during order process to ensure relevant approvals are available for Bluetooth features) Bluetooth required B0 Bluetooth not required B1 Bluetooth required * B0 -M (Example...
Open the catalog to page 106 Pages
7 Pages
6 Pages
8 Pages