Introduction
This document offers guidance on selecting door control systems that comply with the Equality Act 2010 and fire regulations, focusing on accessibility and safety requirements.
Specifications
Door closers for BS8300/ADM applications must be power adjustable by spring and conform to BSEN1154. The document highlights the importance of ensuring the entire doorset meets opening force requirements, illustrated by a torque curve.
Equality Act 2010
The Act requires service providers to remove physical barriers for people with disabilities. Door closers must have an opening force below 30N between 0º and 30º and below 22.5N between 30º and 60º. Dormakaba door closers are tested to meet these standards.
Fire Regulations
BS EN 1154 specifies minimum performance levels for door closing devices, including fire door suitability. Closers must complete 500,000 cycles without performance loss and be at least size EN 3 for fire doors. Dormakaba products are CE marked and CERTIFIRE approved.
Building Regulations
Approved Document B requires third-party fire test certification. The Fire Safety Order 2005 places compliance responsibility on building owners, with penalties for non-compliance. Dormakaba offers risk assessment assistance.
Door Closer Selection
The document provides a guide for selecting door closers based on operation type, fire door requirements, and compliance with BS8300 and ADM standards, including tables for various door closer types and specifications.
Product Specifications
Detailed specifications for dormakaba door closers, including cam action, rack & pinion, and floor spring models, are provided, listing compliance with EN standards and minimum door width requirements.
Conclusion
This brochure serves as a comprehensive guide for selecting door controls that comply with accessibility and fire safety regulations, ensuring legal compliance and user safety.
Overview
The document provides technical specifications and performance details for door control products, focusing on torque curves, door sizes, and compliance with standards like BS8300 and EN1154.
Specifications
  • Products like TS72V/TS72VBC, RTS87, ITS96, TS83, and TS73V are detailed with size ranges (EN1-6) and minimum door widths at EN3.
  • Torque curves show the relationship between door opening angle and required torque.
Standards and Compliance
  • BS8300/ADM compliance emphasizes effective clear widths for accessibility.
  • BS EN1154 recommendations for door closer power sizes based on door width are outlined.
Recommendations
  • Automatic doors are recommended for external doors to ensure accessibility, with options like sliding, folding, swing, low energy swing, and revolving doors.
  • Cam Action closers are preferred over standard rack and pinion closers due to lower opening resistance and compliance with BS8300 and ADM requirements.
Key Data from Graphs
  • Torque curves indicate the torque required at various door opening angles, highlighting product performance.
  • Typical door sizes range from 826mm to 926mm, with specific minimum widths achievable at EN3 for each product.
Specifications and Features
BS8300 emphasizes minimal resistance on doors when opened slowly, achievable with 'thinking backcheck' door closers. Dormakaba offers overhead door closers with this feature.
Importance of Regular Maintenance
Regular maintenance prevents increased resistance in door fittings, which can hinder accessibility. Dormakaba provides comprehensive maintenance packages.
Frequently Asked Questions
  • Variable Power Door Closers: BS8300 recommends variable power door closers for flexibility and compliance with opening force requirements.
  • Door Width Requirements: Dormakaba offers solutions for narrower doors starting from 826mm, meeting minimum requirements.
  • Electrically Powered Hold Open Devices: Options like ITS96 EMF and TS93 EMF do not need to comply with the 30N opening force when powered.
  • Swing Free Door Closers: These closers operate without resistance and are activated only during a fire or power failure.
  • Power Sizes for Non-Fire Doors: There is no legal minimum closing force for non-fire doors, allowing adjustments below size EN3.
Contact Information
Dormakaba UK & Ireland provides contact details for further inquiries and support.
See more

Catalog excerpts

whichdoorcontrolbrochure-1

Which Door Control? Meeting the requirements of the Equality Act & Fire regulations

 Open the catalog to page 1
whichdoorcontrolbrochure-2

Which Door Control? Which Door Control? Introduction There are two main considerations in specifying door controls: • Does it meet the requirements of the Equality Act 2010? • If applied to a fire door - does it satisfy the fire regulations? This brochure will help you select the correct door control for your application. Fire Regulations Equality Act 2010 BS EN 1154 Controlled Door Closing Devices This gives the minimum performance levels for door closing devices, in relation to door width and mass. It also classifies closers for general suitability for use on fire doors, safety in use, and...

 Open the catalog to page 2
whichdoorcontrolbrochure-3

Which Door Control? Which Door Control? How to select a door closer that complies with BS8300 and ADM* Is the door you require a Fire Door? NON-FIRE RESISTING DOORS REQUIRED TO SELF-CLOSE There is no legal requirement for a minimum closing force for door closers on non-fire doors so they can be adjusted below size EN3 to make the opening forces as low as possible. However the closer should be able to successfully close the door and must not exceed the opening force limits set out in BS8300/ADM* Define the access route Right angle approach at least 1500mm wide Right angle approach at least 1200-1499mm...

 Open the catalog to page 3
whichdoorcontrolbrochure-4

Which Door Control? Minimum achievable door width at EN3 = 767mm Third Party Testing Torque Curve 80 100 120 Door opening angle 120 80 100 Door opening angle 80 100 120 Door opening angle 80 100 120 Door opening angle 80 100 120 Door opening angle Minimum Minimum Minimum Minimum achievable achievable achievable achievable Product TS83 RACK & PINION DOOR CLOSERS New improved New improved performance New improved performance improved performance performance Minimum achievable door width at EN3 = 800mm Minimum achievable door width at EN3 = 783mm Minimum achievable door width at EN3 = 800mm MinimumMinimum...

 Open the catalog to page 4
whichdoorcontrolbrochure-5

Which Door Control? Which Door Control? Door Closer Power Settings Under BS EN1154 door closer power sizes are recommended as follows in respect of door width. However any fire door must be fitted with a closer size EN3 minimum, irrespective of width. For further information on the regulations regarding fire doors please see page 3. External Doors ADM1 states that "a non-powered manually operated entrance door, fitted with a self-closing device capable of closing the door against wind forces and the resistance of draught seals, is unlikely to be openable by many people, particularly those who...

 Open the catalog to page 5
whichdoorcontrolbrochure-6

Which Door Control? Which Door Control? Frequently Asked Questions 1. In BS8300 it states that the door closer should be of a variable power type. Can a fixed size door closer be used on fire doors? In general a fixed powered closer with a typical efficiency of 60-65% (BS EN1154 requires a minimum of 55% at EN3) would be unlikely to comply with the 30N opening force. Similarly, door closers with power adjustable only by template (selectable power) are not recommended. However, very high efficiency fixed power closers such as the TS91 Cam Action Closer can comply with the required opening forces...

 Open the catalog to page 6

All Dormakaba catalogs and technical brochures

  1. Charon

    12  Pages

  2. Kerberos

    16  Pages

  3. Kentaur

    20  Pages

  4. KTC 3/KTC 4

    12  Pages

  5. KTC 2

    11  Pages

  6. Geryon

    24  Pages

  7. pextra Q

    16  Pages

  8. penta

    16  Pages

  9. Orthos PIL-M02

    12  Pages

  10. Orthos

    20  Pages

  11. Kaba EACM

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.