Catalog excerpts
Swing door Operating & Maintenance Manua For power-operated doors to EN 16005 Important warranty, user information and service record for your automatic door
Open the catalog to page 1SWING DOOR LOG BOOK Door system data 4 Report for Initial Inspection 5 First entry last exit procedure 7 (if fitted) Daily checks 8 Regular inspection and maintenance 9 The purpose of this manual is to make the user aware of the important steps for the operation and maintenance of the ED Series door operator to ensure safe and reliable operation during its working life. This manual should be retained by the door user as evidence of its correct installation and routine care to comply with safety requirements EN16005: 2012. Used in conjunction with the door installers commissioning compliancy...
Open the catalog to page 2SWING DOOR LOG BOOK dormakaba^ Warranty Statement Thank you for purchasing a dormakaba product which has been designed and manufactured to provide many year's problem-free operation. All products sold by Dorma UK Ltd are warranted against defect in materials and workmanship for a period of 12 months from the date of purchase on a return to factory basis. If you believe this product has a defect or has failed during normal use within the warranty period, please contact the authorised agent from whom you bought the product and who will make arrangements for its return. Alternatively, if your...
Open the catalog to page 3SWING DOOR LOG BOOK Door system data In order that an automatic door operator may comply with the requirements of EN16005:2012 a risk assessment should be carried out prior to installation which assesses the risk to users. It is the responsibility of the installer to ensure that a door system is compliant.
Open the catalog to page 4SWING DOOR LOG BOOK Report for initial inspection To be completed by a qualified technician at installation The following list of components and functions to be inspected is only a reference and shall help the inspector during inspection. From case to case, the inspection can be more or less comprehensive. In principle, the inspector has to perform a visual inspection and functional tests to check the system for completeness. In addition, the system status and the efficiency of the components and the respective safety equipment require inspection. Please consider the separate inspection...
Open the catalog to page 5SWING DOOR LOG BOOK User guide Operator Rocker Switches Power supply Internal Program Switches Internal program switch OFF Adjust both switches to ‘0’. AUTOMATIC Adjust the front switch to to ‘0’, and the other switch to ‘I’. Low Energy Unit – the door can be used manually, or automatically using the operating devices that have been installed (e.g. push pads) PERMANENTLY OPEN Adjust the front switch to to ‘0’, and the other switch to ‘II’. Power Supply Switch OFF This will remove power to the operator and the door will settle into a closed position. EXIT ONLY Adjust the front switch to to...
Open the catalog to page 6SWING DOOR LOG BOOK Remote Programme Switch First entry last exit procedure (if fitted) For installations where access to the Operator Rocker Switches is not convenient or safe a Remote Programme Switch may be installed. This will appear as below. The purpose of this system is to allow an opening of the door when the Program Switch is in the OFF position and the sensors are not operable. There will be a GREEN BUTTON near to the door on the inside of the building To EXIT the building: Program switch settings Program switch settings OFF PERMANENTLY OPEN 1. Turn the program switch to the OFF...
Open the catalog to page 7SWING DOOR LOG BOOK A safety check should be performed daily by the facility operator on each automatic door. Activation Walk toward the door at a normal pace. The door should start opening before you reach a minimum of 1000mm from the door. If the door is an escape route, a minimum of 1500mm applies in the direction of escape. If the door opens toward you, the measurements are taken from the front edge of the door in the fully open position. Repeat for the other side if the door has two-way operation. Safety Note: In order to test the safety sensors we recommend using an approved test...
Open the catalog to page 8SWING DOOR LOG BOOK Regular inspection and maintenance To be undertaken by a qualified technician. The following list describes what has to be done during the maintenance of dormakaba door systems. Always consider the mounting and operation instructions during maintenance. Please observe the requirements for fire doors, emergency exits and escape routes during inspection, if applicable. The current state of technology has to be taken into consideration when assessing the door system with regard to safety-related questions. Note down any safety-relevant error/deficit in the log book and on...
Open the catalog to page 9SWING DOOR LOG BOOK The facilities operator should ensure that this log book is available for the qualified technician on his arrival at site. If it is not available then it is the responsibility of the facilities operator to record the visit.
Open the catalog to page 10SWING DOOR LOG BOOK dormakabai^ Visit date
Open the catalog to page 11SWING DOOR LOG BOOK Visit date
Open the catalog to page 12SWING DOOR LOG BOOK dormakabai^ Visit date
Open the catalog to page 13SWING DOOR LOG BOOK Visit date
Open the catalog to page 14SWING DOOR LOG BOOK dormakabai^ Visit date
Open the catalog to page 15CENTRAL LOCATIONS dormakaba DORMA UK Ltd Wilbury Way Hitchin, Herts SG4 0AB dormakaba Kaba Ltd Lower Moor Way Tiverton, Devon EX16 6SS SERVICE BRANCHES SCOTLAND Unit 1, Almond Road, Middlefield Industrial Estate, Falkirk FK2 9HQ LONDON NORTH & SOUTH Wilbury Way Hitchin Hertfo rdshire SG4 0AB NORTH EAST 55 Aiden Cou rt Bede Industrial Estate Jarrow, Tyne and Wear NE323EF IRELAND PO Box 1050 Maynoo th Co. Kildare MIDLANDS Unit 7, Oaks Industrial Estate, Coalville, Leicester LE67 3NQ SOUTH WEST Lower Moor Way Tiverton Devon EX16 6SS NORTH WEST Unit 10, Meadow Business Park Meadow Lane, Bolton...
Open the catalog to page 16All Dormakaba catalogs and technical brochures
-
Kaba exos 9300 Basic system
2 Pages
-
Kaba exos 9300
2 Pages
-
SST FLEX
12 Pages
-
Kaba EACM
24 Pages
-
Airport solution catalogue
16 Pages
-
Combi B 30
4 Pages
-
B-eco
2 Pages
-
2019 Orthos Personal Interlocks
20 Pages
-
RTS 85
8 Pages
-
dormakaba digital cylinder
2 Pages
-
OFFICE Mundus
2 Pages
-
dormakaba c-lever compact
2 Pages
-
Kaba smart key
2 Pages
-
dormakaba c-lever pro
2 Pages
-
AUDITCON® 2 SERIES LOCKS
4 Pages
-
Kaba 20
2 Pages
-
KTC 2
12 Pages
-
KTV 3 KTV 4 KTV ATRIUM
28 Pages
-
cyber-security
8 Pages
-
whichdoorcontrolbrochure
7 Pages
-
lodging-brochure
12 Pages
-
Push Butoon Lock Brochure
16 Pages
-
dormakaba Overview Brochure
17 Pages
-
Padlock and Enclosure Lock
16 Pages
-
Charon Turnstiles
12 Pages
-
hsb-and-hsg
16 Pages
-
airport-solutions
24 Pages
Archived catalogs
-
Orthos Personal Interlocks
24 Pages