Technical Specifications:
The document provides specifications for DEKAL's ALB series load banks (ALB-45AP, ALB-80AP, ALB-100AP, ALB-120AP, ALB-140AP). These load banks operate at 115/200 V AC with a frequency of 400 Hz. The power range varies from 0 to 144 kW, with fine adjustments available via a potentiometer. Forced air cooling is specified, with varying capacities depending on the model.

Load Adjustment:
Load adjustments are available in sequence steps, ranging from 5 to 17 steps, depending on the model. Each step increases the load in increments of 8 kW.

Indications and Meters:
The load banks are equipped with analog volt, ampere, and frequency meters, all of which are moving iron class meters. Additional indicators include phase indication, phase rotation, and interlock circuit.

Testing Procedures:
Proposed procedures for GPU testing and engine decarbonizing are outlined, detailing load increase and decrease times.

Dimensions and Weight:
The load banks have specified dimensions and weights, with transport casing details provided. The units are coated with fine powder and have an aluminum frame with black laminated plywood panels.

Advantages:
The load banks are designed for simple operation, suitable for non-trained personnel, and require no maintenance. They are silent, environmentally robust, and equipped with safety features such as phase detection and thermal protection. The units are CE certified and comply with various international standards.

Additional Features:
The load banks include a 400 Hz 6-pole receptacle, a 28 V DC control circuit, and are made of non-corrosive materials. They offer a short worldwide delivery period, spare parts availability, and a 2-year warranty with an extension option.
See more

Catalog excerpts

PORTABLE RESISTIVE 400 Hz LOAD BANKS - ANALOG PANEL-1

DEKAL POWER LLC UL. LUDVIKA PLAMBERGERJA 25 SI-2204 MIKLAVZ NA DR. POLJU SLOVENIA - EUROPE DEKAL LOAD BANKS USA LLC 2000 TECHNOLOGY DRIVE PITTSBURGH, PA 15219 - USA Tel.: +1.800.323.9172 * Cell: +1.954.516.4245 Email: info@ dekalloadbanks-us.com Web: www.dekalloadbanks-us.com PORTABLE RESISTIVE 400 Hz LOAD BANKS - ANALOG PANEL SPECIFICALLY DESIGNED RUGGED UNITS USED FOR THE TESTING AND SERVICING OF 400 Hz 115 / 200 V GPUs TECHNICAL SPECIFICATION VOLTAGE [V] * FREQUENCY [Hz] LOAD / POWER [kW / kVA cosφ= 1] FINE ADJUSTMENT - POTENTIOMETER RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS - 8 kW STEPS POWER [kW / kVA cosφ= 1] FORCED AIR COOLING [m³/min & CFM] INDICATIONS ANALOG VOLT METER ANALOG AMPERE METER ANALOG FREQUENCY METER VOLT METER - MOVING IRON CLASS 1.5 AMPERE METER – MOVING IRON CLASS 1.5 FREQUENCY METER - MOVING IRON CLASS 0.5 LIGHT INDICATION GPU TESTING PROCEDURE* ENGINE DECARBONISING* PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT [E&F] *Proposal procedure: LOAD raising from 0 100% 30 seconds; HOLD at 100% 5 minutes; LOAD decrease from 100 0% 10 minutes *Proposal procedure: LOAD raising from 0 100% 30 seconds; HOLD at 100% 45 minutes; LOAD decrease from 100 0% 15 minutes DIMENSIONS & WEIGHT LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs LOAD BANK PAINTING / TRANSPORT CASING FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL Including transport carrying case per unit / All specifications are s

 Open the catalog to page 1
PORTABLE RESISTIVE 400 Hz LOAD BANKS - ANALOG PANEL-2

DEKAL POWER LLC UL. LUDVIKA PLAMBERGERJA 25 SI-2204 MIKLAVZ NA DR. POLJU SLOVENIA - EUROPE DEKAL LOAD BANKS USA LLC 2000 TECHNOLOGY DRIVE PITTSBURGH, PA 15219 - USA Tel.: +1.800.323.9172 * Cell: +1.954.516.4245 Email: info@ dekalloadbanks-us.com Web: www.dekalloadbanks-us.com ADVANTAGES of 400Hz AC LOAD BANK  Simple operation suitable for non-trained operators and personnel; no maintenance required  Suitable for workshop or airside operation; silent unit rated at <70 dB(A) at 7m / 23Ft  Environmental operating temperature from -20 ºC to 55 ºC / -4 ºF to 122 ºF  Cant protection - load bank...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.