Precautions: To prevent injury or equipment damage, ensure cables are routed away from high-current or high-voltage sources. Unauthorized modifications can void warranties and regulatory compliance. The product is intended for industrial use and does not contain user-serviceable parts.
Symbols: The guide uses symbols to indicate warnings (risk of death or injury), cautions (risk of property damage), notes (additional information), and tips (suggestions and shortcuts).
MX-1000 Layout: The device includes a rotatable scanner head, indicator LEDs, trigger buttons, a power button, a touch screen, and optional pistol grip with its own trigger button.
Accessories: Includes batteries, pistol grip, belt holster, charging stations, multi-device and multi-battery chargers, and USB Type-C battery charger kits. Accessories are designed to enhance functionality and ease of use.
Assembly Instructions: Detailed steps for assembling the reader, including connecting the mobile device and securing the top cover. The pistol grip and battery installation are also covered.
Installation: Installation requires the DataMan Setup Tool software. The manual provides detailed procedures and specifications. Ensure all components are present and undamaged.
Specifications: The MX-1100 Imager specifications include weight, operating and storage temperatures, humidity, environmental protection (IP65), and supported codes. The imager features a 1/3 inch CMOS sensor with specific resolution and lens type.
Compliance Statements: The MX-1000 meets various international regulatory standards, including FCC, ICES, EN, and others. It complies with EU Directive 2014/30/EU and includes guidelines for safe operation and disposal under WEEE regulations.
Safety and Regulatory: The product is a Class A device, potentially causing radio interference in domestic environments. Compliance with FCC, Canadian, and other international standards is confirmed.
Environmental Compliance: The product adheres to the EU WEEE Directive, encouraging proper disposal and recycling to minimize environmental impact.
See more

Catalog excerpts

MX-1000 Series-1

MX-1000 Series Quick Reference Guide

 Open the catalog to page 1
MX-1000 Series-2

Precautions To reduce the risk of injury or equipment damage, observe the following precautions when you install the Cognex product: l Route cables and wires away from high-current wiring or high-voltage power sources to reduce the risk of damage or malfunction from the following causes: over-voltage, line noise, electrostatic discharge (ESD), power surges, or other irregularities in the power supply. Changes or modifications not expressly approved by the party responsible for regulatory compliance could void the user’s authority to operate the equipment. Ensure that the cable bend radius begins...

 Open the catalog to page 2
MX-1000 Series-3

Symbols The following symbols indicate safety precautions and supplemental information: WARNING: This symbol indicates a hazard that could cause death, serious personal injury or electrical shock. CAUTION: This symbol indicates a hazard that could result in property damage. Note: This symbol indicates additional information about a subject. Tip: This symbol indicates suggestions and shortcuts that might not otherwise be apparent.

 Open the catalog to page 3
MX-1000 Series-4

Scanner head (rotatable by 45°) Indicator LEDs Side trigger buttons Power button Touch screen Home button Speaker vents Recessed area for mobile camera Slider to lock battery cover

 Open the catalog to page 4
MX-1000 Series-5

Battery cover Lanyard hook Trigger button on the pistol grip* *Pistol grip is optional

 Open the catalog to page 5
MX-1000 Series-6

MX-1000 Series Accessories Accessory Battery for reader (3120 mAh) Battery for pistol grip accessory (3070 mAh) DMA-HHBATTERY-01 Pistol grip Note: The grip features its own trigger button and an additional battery which can be charged via the charging station. Belt holster Charging station (inductive) DMA-MTBASE-US DMA-MTBASE-EU Charging station (non-inductive) DMA-MTBASEP-US DMA-MTBASEP-EU Multi-battery charger Multi-device charger

 Open the catalog to page 6
MX-1000 Series-7

Accessory Power supply for charging station 24V/24W USB Type-C battery charger kits 1. USB Type-C Battery Cover (DMA-MXUSB-00) + USB Type-C 3Amp Car Charger (DMA-MXUSB-CHARGER) USB Type-C Battery Cover (DMA-MXUSB-00) + Handstrap (DMA-MXSTRAP-00) USB Type-C Battery Cover (DMA-MXUSB-00) + USB Type-C 3Amp Car Charger (DMA-MXUSB-CHARGER) + Handstrap (DMA-MXSTRAP00) 1 Using or storing the device outside of the recommended temperature ranges may damage or reduce the lifespan of the battery. Leaving the MX Series Mobile Terminal with a mobile device in direct sunlight for an extended amount of time...

 Open the catalog to page 7
MX-1000 Series-9

Dimensional Drawings

 Open the catalog to page 9
MX-1000 Series-10

Field of View and Reading Distances Note: Due to tolerances, ranges can vary by +/- 5 mm for small codes to +/- a couple of centimeters for large codes.

 Open the catalog to page 10
MX-1000 Series-11

Place the rubber insert on the base unit. Plug the USB cable into the base unit. Put the mobile device on the rubber insert and connect it to the base unit with the USB cable. Open the back cover to take out the reader battery. Plug the pistol grip cable into the grip connector. Insert the reader battery. Tighten the screws to fix the top cover. Note: For details, see the MX-1000 Reference Manual. For a list of supported mobile devices, please contact Cognex. Assemble the reader with the pistol grip and tighten the screws.

 Open the catalog to page 11
MX-1000 Series-12

Installation Installation procedures and specifications are presented in detail in the MX-1000 Reference Manual, which is installed with the DataMan Setup Tool. From the Windows Start menu, select the following to access the manual: All Programs > Cognex > DataMan Software v6.1.0 > Documentation. Note: If a standard component is missing or damaged, immediately contact your Cognex Authorized Service Provider (ASP) or Cognex Technical Support. CAUTION: All cable connectors are keyed to fit the connectors on the reader. Do not force the connections or damage may occur. Install Software and Documentation...

 Open the catalog to page 12
MX-1000 Series-13

510 g (675 g with pistol grip) Operating Temperature Storage Temperature Charging Temperature Maximum Humidity 1-D: UPC/EAN/JAN, Codabar, Interleaved 2 of 5, Code 39, Code 128, Code 93, Pharmacode, GS1 DataBar, PDF417, Micro PDF417 2-D: Data Matrix, QR Code, and MicroQR Code, DotCode and postal code Power Supply Requirements Battery power Expected operating time for typical scan batches (400 scan per hour) with a fully charged battery

 Open the catalog to page 13
MX-1000 Series-14

Image Sensor Image Sensor Properties Image Resolution (Pixels) 752 x 480 global shutter sensor Lens Type 6.2 mm with different focal positions for MX-1000 and MX-1100, M12 lens with IR blocking filter LED Wavelengths The following table shows LED types and the related wavelengths: LED

 Open the catalog to page 14
MX-1000 Series-15

Charging Station Specifications Specification Charging Station Operating Temperature Storage Temperature Maximum Humidity Power Supply Requirements 24 V, 24 W maximum LPS or NEC Class 2 power supply 0.5A (inductive) and 1A (non-i

 Open the catalog to page 15
MX-1000 Series-16

Compliance Statements The MX-1000 has Regulatory Model 1AA7 (inductive) and Regulatory Model R00078 (non-inductive) , and meets or exceeds the requirements of all applicable standards organizations for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow. Please read these guidelines carefully before using your device. The following specifications apply to the MX-1000 readers: Regulator FCC 47 CFR Part 15, Subpart B Class A European Community Japan Korea Note: For the most current CE...

 Open the catalog to page 16
MX-1000 Series-17

Safety and Regulatory European Compliance This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate FCC Class A Compliance Statement Canadian Compliance measures. This equipment complies with the essential requirements of EU Directive 2014/30/EU. Declarations are available from your local representative. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against...

 Open the catalog to page 17
MX-1000 Series-18

This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment, if not properly disposed. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way. The crossed out wheeled bin symbol informs you that the product should not be disposed...

 Open the catalog to page 18

All Cognex catalogs and technical brochures

  1. MX-1502

    28  Pages

  2. MX-1100

    23  Pages

  3. VisionPro

    18  Pages

  4. Cognex Designer

    18  Pages

  5. CVL

    23  Pages

  6. DataMan® 8050

    23  Pages

  7. DataMan® 8700

    23  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.