1. Catalogs
  2. Cognex
  3. DataMan® 260 Series

DataMan® 260 Series

DataMan® 260 Series
1 / 34 PagesView full catalog

DataMan® 260 Series

Product catalog summary
Precautions: The guide stresses the importance of using the correct power supply, avoiding device connection or disconnection when linked to a PC, and keeping cables away from high-current or high-voltage sources to prevent damage. Unauthorized modifications can void the warranty, and the device should be used according to the manual instructions.
Symbols: Various symbols indicate warnings, cautions, notes, and tips for safe and effective use.
Product Overview: The DataMan 260 includes features such as illumination LEDs, LED aimers, a trigger button, and various status indicators, along with connectors for power, I/O, RS-232, and Ethernet.
Accessories: Lists available lens options, covers, illuminations, filters, cables, and mounting brackets for the DataMan 260.
Dimensional Drawings: Provides figures showing the size of the DataMan 260 in different configurations.
Field of View and Reading Distances: Details the horizontal and vertical field of view values for different devices and lenses, as well as reading distances for 1D and 2D codes.
Connecting the Reader: Instructions for mounting the reader, connecting Ethernet and breakout cables, and ensuring proper power supply connections.
Installation: Installation procedures are detailed in the DataMan 260 Reference Manual, accessible via the DataMan Setup Tool.
Specifications: Lists the technical specifications of the DataMan 260, including weight, operating temperature, humidity, environmental protection, shock and vibration resistance, and power requirements.
Regulations/Conformity: The DataMan 260 complies with various international standards and regulations, including FCC, CE, and RoHS directives.
Environmental Considerations: Encourages proper disposal and recycling of the product to minimize environmental impact.
Overview: This document outlines China's management methods for controlling pollution by electronic information products, focusing on hazardous substances.
Key Sections:
1. Hazardous Substances: Lists hazardous substances such as Lead (Pb), Mercury (Hg), Cadmium (Cd), Hexavalent Chromium (Cr (VI)), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE).
2. Regulatory Models: Mentions models 1AA5, 1ABD, 1AA0, and 1ABF in relation to the presence of these substances.
3. Compliance Table: A table indicates compliance with the SJ/T 11364 provisions, using 'O' to denote that the hazardous substance is below the limit requirement of GB/T26572 - 2011, and 'X' to indicate that it is above the limit in at least one material.
4. Standards and Regulations: References the GB/T26572 - 2011 standard for hazardous substance limits.
Conclusion: Emphasizes adherence to specific regulatory standards to manage hazardous substances in electronic products.
See more

Catalog excerpts

DataMan® 260 Series-1

DataMan® 260 Series Quick Reference Guide

 Open the catalog to page 1
DataMan® 260 Series-2

Precautions To reduce the risk of injury or equipment damage, observe the following precautions when you install the Cognex product: l This device requires the use of an LPS or NEC class 2 power supply (nonPoE device) or the use of a PoE Class 1 (PoE device). Do not connect or disconnect this device from the I/O module or 15-pin USB adapter cable when the I/O module or adapter cable is connected to a PC. Route cables and wires away from high-current wiring or high-voltage power sources to reduce the risk of damage or malfunction from the following causes: over-voltage, line noise, electrostatic...

 Open the catalog to page 2
DataMan® 260 Series-3

This product does not contain user-serviceable parts. Do not make electrical or mechanical modifications to product components. Unauthorized modifications can void your warranty.

 Open the catalog to page 3
DataMan® 260 Series-4

Symbols The following symbols indicate safety precautions and supplemental information: WARNING: This symbol indicates a hazard that could cause death, serious personal injury or electrical shock. CAUTION: This symbol indicates a hazard that could result in property damage. Note: This symbol indicates additional information about a subject. Tip: This symbol indicates suggestions and shortcuts that might not otherwise be apparent.

 Open the catalog to page 4
DataMan® 260 Series-5

Product Overview Illumination LEDs Trigger button Power indicator Train status indicator Good/bad read indicator Network status indicator Error indicator Tune button

 Open the catalog to page 5
DataMan® 260 Series-6

Ethernet connector Note: *Use only one set of mounting holes (either 3 OR 4) for mounting. Note: The five status LEDs together also function as a peak meter using an orange light. DataMan 260 Accessories LENS OPTIONS, COVERS, ILLUMINATIONS AND FILTERS Accessory Name Accessory Number IR 6.2 mm lens kit, 3 -position with IR LED IR 16 mm lens kit 16 mm lens with extended optics mount (requires the use of an extended front cover and high-powered red LED) UV Light Kit for 6.2 mm lens (365nm) Liquid Lens Module (LLM) to be used with 6.2 mm lens or 16 mm lens Accessory Image

 Open the catalog to page 6
DataMan® 260 Series-7

ImageMax kit Clear lens cover* Clear lens cover, ESD safe* Polarized front cover* Extended lens cover, un-polarized** Extended lens cover, half-polarized ** Extended lens cover, fully polarized** Blue bandpass filter Red bandpass filter Red LED illumination* White LED illumination* Blue LED illumination* High Powered red LED illumination** Note: *Use with a 6.2 mm lens only! **Use with a 16 mm lens only! ***ESD safe

 Open the catalog to page 7
DataMan® 260 Series-8

Accessory Name Accessory Number CCBL-05-01 CCB-M12x12Fy-xx (y=S: straight / y=A: angled *, xx specifies length) CCB-M12xDB9Y-05 Connection cable RS-232 Adapter cable, M12x12 to M8x4/M8x5, 0.5 m X-Coded to RJ45 Ethernet Cable Adapter cable, ETH, M12, X-CODED/A-CODED, 0.5 m CCB-84901-2001-xx, where xx can be 02, 05, 10, 15 or 30, indicating length in meters CCB-M12x8MS-XCAC DM100-UBRK-000 Universal Mounting Bracket Pivot Mounting Bracket Accessory Image

 Open the catalog to page 8
DataMan® 260 Series-9

Dimensional Drawings The size of the DataMan 260 in the angled configuration is shown in the following figures:

 Open the catalog to page 9
DataMan® 260 Series-11

The size of the DataMan 260 with the extended lens cover configuration is shown in the following figures:

 Open the catalog to page 11
DataMan® 260 Series-13

The size of the DataMan 260 with the side read mirror configuration is shown in the following figure:

 Open the catalog to page 13
DataMan® 260 Series-14

Field of View and Reading Distances Horizontal Field of View values Device DM260 Short Range: 77 mm [3.0 Long Range: 115 mm [4.5 Short Range: 34 mm [1.3 Short Range: 50 mm [1.9 in] Short Range: 87 mm [3.4 Long Range: 123 mm [4.8

 Open the catalog to page 14
DataMan® 260 Series-15

Vertical Field of View values Device

 Open the catalog to page 15
DataMan® 260 Series-16

Short Range: 28 mm [1.1 Short Range: 42 mm Long Range: 92 mm [3.6 Long Range: 108 mm [4.25 in] Long Range: 135 mm [5.3 Long Range: 223 mm

 Open the catalog to page 16
DataMan® 260 Series-17

Reading Distance for 1D and 2D Codes with 6.2 mm Lens Distances in mm/ 2D min. code 6.2 mm lens Long Range Distances in mm/ 1D min. code 6.2 mm lens Long Range

 Open the catalog to page 17
DataMan® 260 Series-18

Distances in mm/ 2D min. code 6.2 mm lens Short Range Distances in mm/ 1D min. code 6.2 mm lens Short Range

 Open the catalog to page 18
DataMan® 260 Series-19

Reading Distance for 1D and 2D Codes with 16 mm Lens Distances in mm/

 Open the catalog to page 19
DataMan® 260 Series-20

DataMan 260 Readers with Side Read Mirror The following table shows the Field of View (FoV) widths of DM260 with 6.2 mm lens focused to 190 mm at various distances.

 Open the catalog to page 20
DataMan® 260 Series-22

The following table shows the Field of View (FoV) widths of DM262 with 6.2 mm lens focused to 190 mm at various distances. Device DM262

 Open the catalog to page 22
DataMan® 260 Series-23

Connecting the Reader Perform the following steps: 1. Mount the reader. 2. Connect the Ethernet cable (CCB-84901-2001-05) either to a computer or a switch. 3. Connect the breakout cable (CCBL-05-01). For information on the pinout and wire colors, see section Connections, Optics and Lighting in the DataMan 260 Reference Manual.

 Open the catalog to page 23
DataMan® 260 Series-24

Installation Installation procedures and specifications are presented in detail in the DataMan® 260 Reference Manual, which is installed with the DataMan Setup Tool. From the Windows Start menu, select the following to access the manual: All Programs > Cognex > DataMan Software vx.x.x > Documentation. Note: l l Cables are sold separately. If a standard component is missing or damaged, immediately contact your Cognex Authorized Service Provider (ASP) or Cognex Technical Support. CAUTION: All cable connectors are keyed to fit the connectors on the reader. Do not force the connections or damage...

 Open the catalog to page 24
DataMan® 260 Series-25

Connect the Ethernet Cable 1. Connect the Ethernet cable's M12 connector to the reader ENET connector. 2. Connect the Ethernet cable’s RJ-45 connector to a switch/router or PC, as applicable. Connect the Breakout Cable Note: You can clip unused wires short or use a tie made of non-conductive material to tie them back. 1. Verify that the 24VDC power supply is unplugged and not receiving power. 2. Attach the Breakout cable's +24VDC and GROUND to the corresponding terminals on the power supply. CAUTION: Never connect voltages other than 24VDC. Always observe the polarity shown. 3. Attach the Breakout...

 Open the catalog to page 25
DataMan® 260 Series-26

Install Software and Documentation and Connect the Reader Follow the steps below to connect your reader to power and network: 1. Connect the I/O+RS232+24V cable to your reader. 2. For a network connection, connect your reader through an Ethernet cable to your network. 3. Connect the cable to a 24V power supply. To configure a DataMan 260 reader, the DataMan Setup Tool software must be installed on a networked PC. The DataMan Setup Tool is available from the DataMan support site: http://www.cognex.com/support/dataman. 1. After installing the software, connect the DataMan 260 Series reader to your...

 Open the catalog to page 26

All Cognex catalogs and technical brochures

  1. MX-1502

    28  Pages

  2. MX-1000 Series

    22  Pages

  3. MX-1100

    23  Pages

  4. VisionPro

    18  Pages

  5. Cognex Designer

    18  Pages

  6. CVL

    23  Pages

  7. DataMan® 8050

    23  Pages

  8. DataMan® 8700

    23  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.