COUPLIX® KX-M-EE

COUPLIX® KX-M-EE

Product catalog summary
Specifications:
The COUPLIX KX-M-EE cables are designed for high-temperature applications, with a continuous operating temperature range from -55°C to +260°C. They feature a construction inspired by EN 2714 standards and perform according to EN 3475 and FAR 25. The thermocouple specifications adhere to EN 60584-3 and ISO 8056-1.

Construction Details:
The cable consists of a Nickel-chromium/Nickel-aluminium thermocouple, polyimide and PTFE tapes, a nickel-plated copper spiral shield, and is UV laser printable. The cores are identified by yellow and purple colors.

Electrical and Mechanical Characteristics:
The operating voltage is 600 V RMS. The cable exhibits high resistance to cut-through and abrasion, rated at four stars. It also offers excellent resistance to chemical environments, humidity, and aircraft fluids, rated at five stars.

Fire and Smoke Resistance:
The cable is flame retardant and produces low smoke, complying with EN 3475 and FAR 25 standards.

Applications:
These cables are used for temperature measurement by thermoelectric effect and serve as extension cables to connect thermocouples to reference junctions in equipment.

Options and Customization:
Other cross-sections or constructions are available upon request.

Contact Information:
For further inquiries, contact CGP SAS at 62 route du coin, 42400 Saint-Chamond, France, or via phone at +33 (0)4 77 31 02 54, or email at [email protected].
See more

Catalog excerpts

COUPLIX® KX-M-EE-1

CABLE SOLUTIONS FOR HIGH VALUE-ADDED APPLICATIONS IN AGGRESSIVE ENVIRONMENTS HIGH TEMPERATURE & THIN THERMOCOUPLE & EXTENSION CABLES 1 COUPLIX® KX-M-EE Characteristics Thermal Continuous operating temperature: -55°C to +260°C FEM - Thermocouple 4.10 mV ± 0.06 mV at 100°C EN 60584-3 FEM - Nickel-chromium/Platine wire 2.813 mV ± 0.06 mV at 100°C FEM - Nickel-aluminium/Platine wire -1.282 mV ± 0.06 mV at 100°C ISO 8056-1 Electrical Operating voltage: 600 V RMS Standards and approvals Construction: Inspired of EN 2714 Performances: EN 3475 / FAR 25 Thermocouple: EN 60584-3 / ISO 8056-1 Marking (UV laser printable) 1. On customer specification 2. Inspired of EN 2084: “Product Reference Gauge Country CGP NATO Code Manufacturing Year” Mechanical Cut-through resistance: ★★★★* Resistance to abrasion: ★★★★* EN 3475 Chemical Resistance to chemical environments: ★★★★★ Resistance to humidity: ★★★★★ Resistance to aircraft fluids: ★★★★★ EN 3475 Fire-smoke Flame retardant & Low smoke EN 3475 / FAR 25 Cores identification Two cores: Yellow - Purple For any other request: please contact us Cross Cable section outer diameter Maximum linear weight (kg / km) Maximum linear resistance at 20°C (Q / km) Yellow core < 1,276 Purple core < 550 Shield < 100 Options Other cross-sections or constructions on request Applications Measure of temperature by thermoelectric effect Extension cables serve to connect the open ends of the two wires of a thermocouple at the reference junction in equipment where the thermocouple is not directly connected to the reference junction For further information, please contact us: CGP SAS 62 route du coin, 42400 Saint-Chamond - FRANCE Phone: +33 (0)4 77 31 02 54 [email protected] www.cables-cgp.com ® Registered trademark of CGP. All information is indicative and may be modified without prior notice. Drawings and photos are not contractual. Reproduction is prohibited without the prior agreement of CGP.