AC2000 DSC

AC2000 DSC

AC2000 DSC

Product catalog summary
Overview: The document describes the integration of the AC2000 access control system with the DSC PowerSeries intruder detection system, highlighting features, configuration, and requirements.
Key Features:
  • Seamless integration of AC2000 and DSC systems for centralized security management.
  • Bi-directional integration supporting multiple DSC panels.
  • Virtual DSC keypad for remote arm/disarm operations.
  • Graphical representation of DSC panels on Security Hub Maps.
  • Instant reporting of DSC intruder alarms on AC2000 Security Hub.
  • Support for Ethernet and Serial networks.
Intrusion Detection System: The AC2000 DSC PowerSeries interface allows full integration of DSC intruder alarms with the AC2000 system, enabling centralized monitoring and fast response through graphical maps and alarm icons.
Virtual Keypad: A virtual DSC keypad application replicates the functions of a physical keypad, allowing remote operations such as arming/disarming panels and activating emergency keys.
Ease of Configuration: An intuitive software interface simplifies the configuration of DSC panels within the AC2000 system, reducing data entry and supporting large panel systems.
Central Monitoring: Alarms from DSC panels are transmitted to the AC2000 system via Ethernet or RS232, allowing for centralized management and reporting through the AC2000 Security Hub.
Requirements:
  • AC2000 v7.1 Service Pack 1 or later.
  • AC2000 AE/SE/Lite v6.6 or later.
  • ECM (Ethernet Communications Module).
  • DSC PowerSeries IT-100 module.
  • Tibbo DS Manager software for Ethernet connections.
See more

Catalog excerpts

AC2000 DSC-1

CEM SYSTEMS From Tyco Security Products AC2000 DSC PowerSeries Interface Intrusion Detection SystemFeatures that make a difference: Seamless integration of AC2000 access control system and DSC intruder system High level Bi-directional integration of DSC intruder panels Multiple panels supported Integrated virtual DSC keypad used to remotely arm/disarm DSC panels and alarms DSC panels and sensor locations represented on Security Hub Maps DSC intruder alarms reported instantly on AC2000 Security Hub application for central monitoring DSC intruder alarms included into AC2000 alarm reports Ethernet and Serial networks supported Intuitive setup and configuration tool The AC2000 DSC PowerSeries intruder interface enables alarms from DSC intruder detection system (IDS) to be fully integrated with the AC2000 security management system. This enables AC2000 to act as the central Security Management System (SMS), The AC2000 DSC PowerSeries interface enables inputs from intruder panels to be placed as icons on the AC2000 Security Hub application. This provides, on a single screen, a graphical representation of the physical layout of intruder sensors and allows for central alarm monitoring of both access control and intruder alarms. Using the AC2000 DSC PowerSeries interface and the central AC2000 Security Hub graphical maps, system operators can quickly identify an intruder alarm and its exact location on site. This allows for a fast response time and a centralised and integrated viewpoint of both security systems. Combined with CCTV integration, intruder alarms can be used to enable video images to be recorded on a compatible video management system. The IDS alarms can also be forwarded to other 3rd party monitoring systems such as Building Management System (BMS) for example. Virtual Keypad AC2000 DSC PowerSeries interface also features a virtual DSC keypad application. This provides the same function as the real key pad, without needing to attend the actual keypad location. The virtual keypad is used by a workstation operator to Arm/ Disarm intruder panels remotely from the AC2000 system. Using the virtual keypad, intruder panels can be reset, navigated and emergency keys activated remotely. Ease of Configuration A simple alarm panel configuration application allows the integration of DSC intruder panel devices within the AC2000 system. Using this intuitive software interface, system administrators give the intruder panel a name, select the number of associated zones, state the starting address and add each panel to the system in groups of 8, 16, 32 or 64 inputs. The alarm panel configuration software simplifies the configuration of larger intruder panel systems by automatically creating and addressing entries in the AC2000 devices table thereby greatly reducing the amount of data the operator must enter. Central monitoring and control of intruder/ access control alarms Alarms from DSC PowerSeries intruder panels are sent to the AC2000 system over Ethernet using

 Open the catalog to page 1
AC2000 DSC-2

CEM SYSTEMSFrom Tyco Security Products an ECM (Ethernet Communication Module) or directly over RS232. Intruder alarms are then extracted and mapped to AC2000 system alarms which are sent to the AC2000 Security Hub application. Alarm icons representing sensor locations can be placed on to Security Hub graphical maps alongside access control readers and camera locations. Alarms are received, processed and reported on the AC2000 Security Hub application for central management by security personnel. AC2000 Security Hub can also show any errors or troubles with the DSC alarm panels, for example low...

 Open the catalog to page 2

All CEM Systems catalogs and technical brochures

  1. SALTO SALLIS

    2  Pages

  2. S700s

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.