CCR

CCR

CCR

Product catalog summary
Compliance and Standards:
The document references compliance with ICAO, FAA, and IEC standards, specifically mentioning the Aerodrome Design Manual Part 5 and AC 150/5345-10, L829.

High Voltage Section:
This section supplies current to the series circuit. Key components include the output transformer, current transformer, lighting arrester, output terminal, and coupling choke.

Low Voltage Section:
Receives input from the control section and manages phase control through a thyristor. Main components are the circuit breaker, power relay, magnet contact, thyristor module, and input choke.

Control Section:
Utilizes a microprocessor for control and monitoring. Settings are adjusted via a keypad, with values displayed on an HMI and LED indicators. Components include interface card, CPU card, power supply card, earth fault power supply card, DO card, and DI card.

Component Features & Benefits:
The unit is free-standing, divided into electronic control, low voltage, and high voltage areas, and is naturally air-cooled. It operates within a temperature range of -40 to +55°C, with output current options of 6.6 or 20 Amps across multiple steps. Efficiency is not less than 90%, with various protections and monitoring capabilities.

Technical Specifications:
- Input Voltage: Options from 208V to 480V, or user request.
- Capacity: Ranges from 2.5 to 30 KW.
- Output Current: 6.6A or 20A, with adjustable steps.
- Power Factor: Not less than 90%.
- Monitoring: Includes over current, open circuit, fuse fault, and various other monitoring features.

Physical Dimensions:
The unit measures 850mm x 1500mm x 625mm, with a weight of 220 Kg and a volume of 0.8 m³.

Contact Information:
Aviasafe GmbH, located in Frankfurt am Main, Germany, with contact details provided for both the head office and factory.
See more

Catalog excerpts

CCR-1

Constant Current Regulator Aviasafe GmbH Headoffice DE 98597 Fambach Neue Wiese 2 DE 60478 Frankfurt am Main/ Germany CONTROL SECTION This Section Constitutes the Control & Monitoring System of the Constant Current Regulator Using a Micro Processor. All Settings and Controls are Made Through a Key Pad and the Actual Values of the CCR are Presented on a HMI and Through LED Indicators. The Main Components of the Control Section are as Follows : • Interface Card • CPU Card • Power Supply Card • Earth Fault Power Supply Card • DO Card • DI Card HIGH VOLTAGE SECTION The High Voltage Section Supplies Current to the Series Circuit and its Main Components are as Follows : • Output Transformer COMPLIANCE ICAO Aerodrome Design Manual Part 5 • Elapsed Time Monitoring • Local Control • Parallel Remote Control • Power Factor : Not Less than %90 FEATURES & BENEFITS • Over Current Protection • Free Standing Unit • Housing Divided into Three Areas : • Lamp Fault Monitoring Electronic Control, Low Voltage & High Voltage • Current Transformer • Lighting Arrester • Output Terminal • Coupling Choke LOW VOLTAGE SECTION The Low Voltage Section Receives the Input From the Control Section and Executes the phase Control Through the Thyristor. • Natural Air Cooled • Operating Temperature Range 40- to 55+℃ It Supplies Power to the Output • Output Current : 6.6 or 20 Amps (1 ,3 ,5 or The Main Components of the Low Voltage 7 Steps) Option : Non Illumination Step • Rating From 2.5 to 30 KW • Output Current Regulation %1.0± • Efficiency : Not Less Than %90 • Open Circuit Protection • Magnet Contact • Input Power Loss Monitoring • Input Choke

 Open the catalog to page 1
CCR-2

CCR Constant Current Regulator Thyristor Phase Control Input Voltage Output Current Brightness Step Power Factor Efficiency Control Remote Control Single Phase 220V 50 / 60 Hz (other voltage upon request) 7 Adjustable steps (1,3, 5 or 7 steps) Option : Non illumination step 1.8A >90% at nominal input and full load >90% at nominal input and full load Parallel : 24 VDC to 60 VDC Serial : RS-485 Dual line Over Current Protection 12 = 6.85A < 4 sec / 12 = 6.93A < 2 sec Open circuit protection l = 1.50A < 1 sec Over current monitoring Open circuit monitoring Fuse fault monitoring Current regulation...

 Open the catalog to page 2

All Aviasafe GmbH catalogs and technical brochures

  1. LRGS

    2  Pages

  2. EL-RN

    2  Pages

  3. EL-RT

    2  Pages

  4. EL-RE

    2  Pages

  5. IN-TE

    2  Pages

  6. IN-RN