Catalog excerpts
Samson S45 INSTALLATION MANUAL AVE-S45-001-IM © 2015 Aveo Engineering Group, s.r.o. All rights reserved. The information contained within this document must not be disclosed, copied or reproduced in whole or in part without prior written permission from Aveo Engineering Group, s.r.o. Distribution of this document shall only be as stated in Table 02 unless otherwise agreed by Aveo Engineering Group, s.r.o.
Open the catalog to page 1INSTALLATION MANUAL
Open the catalog to page 2INSTALLATION MANUAL Manual Administration 0.1 Document approval This document has been established in accordance with an alternative procedure to DOA approved under EASA AP429. This installation manual is applicable for part numbers: • • • • Samson Drop-In Landing Samson Drop-In Taxi Samson Drop-In Landing 28VAC 400Hz Samson Drop-In Taxi 28VAC 400Hz 01. – Dec. - 2016 Petr Nezval Engineer, Aveo Engineering Group, s.r.o. 01. – Dec. - 2016 Georg Hartl Head of DO, Aveo Engineering Group, s.r.o. 0.2 Amendment Record procedure The master copy of this document shall be kept electronically as a...
Open the catalog to page 3INSTALLATION MANUAL 1. PRODUCT INFO Aveo Engineering introduces the exclusive next-generation Samson™ Drop-In PAR46 replacement for Legacy Lights. Environmentally Friendly The Samson uses far less power than competitive products illuminated by mercury-arc, high intensity discharge, or halogen lamps, which means they help to reduce air pollution from carbon emissions. Mercury and Lead-free, this RoHS compliant environmentally-friendly technology helps reduce power consumption and the amount of hazardous waste entering the environment. Finally, a "green" aircraft light! MAIN FEATURES: - FAA...
Open the catalog to page 4INSTALLATION MANUAL 3. TECHNICAL SPECIFICATION DC version Light characteristics: Landing Light / Taxi Light / PAR46 replacement Voltage range: +18..+36 VDC Voltage protection: a. Transcend voltage: 2 second +80V b. Under-voltage lockout: +18VDC, not more; c. Over-voltage lockout: +36VDC, not less. LED quantity: 45pcs Performance: a. Output current: 1.25A per LED b. Output power: 168W c. Input power: 200W +/- 5% Chromaticity: Cool White, Color shade 1C0 Intensity: 328.000 cd peak, see annex 1, 2, 3, 4 Viewing Angle: 12° Landing (symetrical) 40° Taxi (asymetrical) Low temperature slope start:...
Open the catalog to page 5INSTALLATION MANUAL AC version Light characteristics: Landing Light / Taxi Light / PAR46 replacement Voltage range: +27..+29 V AC @ 400Hz Voltage protection: a. Transcend voltage: 2 second +40VAC b. Under-voltage lockout: +26VAC, not more; c. Over-voltage lockout: +30VAC, not less. LED quantity: 45pcs Performance: a. Output current: 0.85A per LED b. Output power: 113W c. Input power: 147,5W +/- 5% Chromaticity: Cool White, Color shade 1C0 Intensity: 240.000 cd peak, see annex 5, 6, 7, 8 Viewing Angle: 12° Landing (symetrical) 40° Taxi (asymetrical) Low temperature slope start: -55°C Ambient...
Open the catalog to page 6INSTALLATION MANUAL
Open the catalog to page 7INSTALLATION MANUAL 6. CARE AND CLEANING OF YOUR AVEO ENGINEERING AVIATION LIGHTS When you receive your Aveo Engineering Aviation Lights, they will have been factory polished and ready to install on the aircraft. If the lights require a deeper cleaning, they should be polished with a quality lamb’s wool sheet and can also be used for deeper polishing. Under no circumstances should any petroleum based product be used to clean the lights.
Open the catalog to page 8INSTALLATION MANUAL – Samson Drop–In Landing DC - Polar Candela Distribution
Open the catalog to page 9INSTALLATION MANUAL – Samson Drop–In Landing DC - Rectangular Candela Distribution
Open the catalog to page 10INSTALLATION MANUAL – Samson Drop–In Taxi DC - Polar Candela Distribution
Open the catalog to page 11INSTALLATION MANUAL – Samson Drop–In Taxi DC - Rectangular Candela Distribution
Open the catalog to page 12INSTALLATION MANUAL – Samson Drop–In Landing AC - Polar Candela Distribution
Open the catalog to page 13INSTALLATION MANUAL – Samson Drop–In Landing AC - Rectangular Candela Distribution
Open the catalog to page 14INSTALLATION MANUAL – Samson Drop–In Taxi AC - Polar Candela Distribution
Open the catalog to page 15INSTALLATION MANUAL – Samson Drop–In Taxi AC - Rectangular Candela Distribution
Open the catalog to page 16All AveoEngineering s.r.o. catalogs and technical brochures
-
Pegatron
12 Pages
-
PosiStrobe CP
12 Pages
-
Samson Drop-In Plus
8 Pages
-
RedBaron Combo HISL Galactica
16 Pages
-
RedBaron XP Galactica
16 Pages
-
SmartStrobe
13 Pages
-
Gulfstream Replacement
2 Pages
-
Installation Manual
10 Pages
-
Ultra Galactica Embedded
2 Pages
-
Ultra Galactica
13 Pages
-
Mooney M20 Installation Manual
21 Pages
-
Brochure
4 Pages
-
AVE-CCPS-01-IM
12 Pages
-
Atlas 10
10 Pages
-
Exceleron DayLite
13 Pages
-
HerculesDropInPlus.
3 Pages
-
Hercules H30
9 Pages
-
/Hercules
11 Pages
-
StrobeTailNano
6 Pages
-
POSISTROBE DAYLITE
2 Pages
-
PosiTail Nano
6 Pages
-
RedBaron MaxiMini
7 Pages
-
PosiStrobe MiniMax
5 Pages
-
RedBaron XP DayLite
1 Pages
-
RedBaron Mini DayLite
2 Pages
-
PICOMAX
1 Pages
-
GLIDERBURST DAYLITE
1 Pages
-
Andromeda DayLite
1 Pages
-
Ultra DayLite
2 Pages
-
Ultra Embedded DayLite
2 Pages