1. Catalogs
  2. AveoEngineering s.r.o.
  3. RedBaron XP Galactica

RedBaron XP Galactica

RedBaron XP Galactica
1 / 16 PagesView full catalog

RedBaron XP Galactica

Product catalog summary
Document Administration
  • Document Approval: Approved under EASA AP429 for RedBaron XP Galactica part numbers.
  • Amendment Record Procedure: Master copy is electronic, with amendments marked by sequential issue numbers and highlighted changes.
  • Effected Pages Procedure: Lists pages affected by amendments and reasons for changes.
Installation Data
  • RedBaron XP Galactica™: Designed for certified aircraft with advanced optics and LED arrays, available in red and white.
  • Operating Instructions: Operates at maximum intensity with aircraft power (14 or 28 volts), voltage range of +9…+36VDC.
  • Installation Schematic/Wiring Diagram: Provides detailed wiring instructions.
  • Control & Power Inputs: Describes wiring connections for power and synchronization.
  • Technical Specification: Includes dimensions, weight, voltage range, power input, and compliance with standards like ETSO C96a and SAE AS8017a.
  • Technical Drawing: Dimensions provided in metric and imperial units.
  • Wiring Chart: Guides on wiring size based on current and wire length.
  • Optic Simulation: Details optic performance for red and white models.
  • Equipment Limitation: Must be powered by 9-36 VDC, meets ETSO C96a standards with some deviations.
  • Care and Cleaning: Lights should be polished with lamb’s wool; avoid petroleum-based products.
  • Testing Before Installation: Instructions for testing lights with a 12V/5A DC power supply.
  • Notes on Installation: Recommends specific mounting screws and procedures.
  • ETSO Requirement Deviation: Details deviations from ETSO-C96a standards.
  • Continued Airworthiness Information: Includes form F-AVE-001A for reporting occurrences.
Circuit/Wiring Protection
Each light includes a Negative Temperature Coefficient (NTC) circuit to reduce operating current and limit internal temperatures, protecting the light and aircraft wiring from thermal runaway, thus extending the lifespan of LEDs and electronic components.
Periodic Inspection Procedure for Galactica Series
Pre-flight checks should verify the operation of Aveo RedBaron Galactica lights. During annual or 100-hour inspections, lights should be visually inspected for condition, operation, and installation. Detailed cleaning instructions are in section 1.10 of the installation manual. Use polarized sunglasses or welder goggles for eye protection during inspection. Replace lights under warranty if conditions exceed limits.
RoHS Compliance Statement
Aveo Engineering complies with EU Directive 2015/863/EU, restricting hazardous substances in electronic equipment. Products are RoHS-compliant, with packaging labeled for conformity if required.
EU REACH Regulation
Aveo Engineering confirms no chemicals used in production or maintenance are listed on the European Chemicals Agency’s Candidate list of Substances of Very High Concern for Authorization.
See more

Catalog excerpts

RedBaron XP Galactica-1

INSTALLATION MANUAL RedBaron XP Galactica Anti-collision LED Light © Aveo Engineering Group, s.r.o. All rights reserved. The information contained within this document must not be disclosed, copied or reproduced in whole or in part without prior written permission from Aveo Engineering Group, s.r.o. Distribution of this document shall only be as stated in Table 02 unless otherwise agreed by Aveo Engineering Group, s.r.o. © Aveo Engineering Group, s.r.o. All rights reserved. The information contained within this document

 Open the catalog to page 1
RedBaron XP Galactica-2

Installation Manual AVE-RBXP-001-IM Issue 05

 Open the catalog to page 2
RedBaron XP Galactica-3

Installation Manual AVE-RBXP-001-IM Issue 05 Document Administration Document approval This document has been established in accordance with an alternative procedure to DOA approved under EASA AP429. This installation manual is applicable for following part numbers: • • RedBaron XP Galactica – Red RedBaron XP Galactica – White Petr Jaroš Engineer, Aveo Engineering Group, s.r.o. Georg Hartl Head of DO, Aveo Engineering Group, s.r.o. Amendment Record procedure The master copy of this document shall be kept electronically as a read only document under the control of Aveo Engineering Group, s.r.o....

 Open the catalog to page 3
RedBaron XP Galactica-4

Installation Manual AVE-RBXP-001-IM Issue 05 Add RB Mini to limitations Add RB Mini to ETSO Requirement Deviation Update warranty Amend figure legend figure 2 Change of structure of document Removal of RedBaron Mini Galactica Addition of optic simulation diagrams Update of Care and Cleaning section Table 01: Document Amendment Record Table Effected Pages Procedure ALL pages affected by ANY raise of issue of this manual will be listed in Table 01 Effected Pages Column. The reason(s) for ALL raise of issue and description of change due to raise of issue will be provided for ALL raises of issue...

 Open the catalog to page 4
RedBaron XP Galactica-5

Installation Manual AVE-RBXP-001-IM Issue 05 Installation data RedBaron XP Galactica™ The RedBaron XP Galactica anti-collision lights were designed for certified aircraft requirements. They represent the cutting edge in optics design and the use of LED arrays that have been optimized for coverage patterns. The exclusive Aveo Rocky Reflectors™ are what separates these lights from any in the industry, and they have been moulded after exhaustive modelling and testing in our parent company's world class LED-array measurement lab. The RedBaron XP Galactica™ version incorporates 40 of the brightest...

 Open the catalog to page 5
RedBaron XP Galactica-6

Installation Manual AVE-RBXP-001-IM Issue 05 Installation Schematic / Wiring Diagram

 Open the catalog to page 6
RedBaron XP Galactica-7

Installation Manual AVE-RBXP-001-IM Issue 05 1.4 YELLOW: BLACK: BLUE: BARE: Control & Power Inputs +UCC - positive strobe power supply line GND - negative common power supply line (ground) SYNC - strobe synchronization line (Mutually interconnect on all installed AveoFlash lights) Aircraft airframe connection Technical Specification Dimensions: Weight: Operating Voltage Range: Input Power – Red Strobe: Input Power – White Strobe: Input Current – Red Strobe: Input Current – White Strobe: Voltage protection: Repetition Flash Rate of Strobe: Ambient temperature: Overheat protection: Recommended...

 Open the catalog to page 7
RedBaron XP Galactica-8

Installation Manual AVE-RBXP-001-IM Issue 05 Device RTCA/DO160 qualified: Test title Temperature / Altitude Temperture variation Operational Shock Explosive Atmosphere Fluid Susceptibility Salt Spray Magnetic Effects Power Input Voltage Spike Audio Freq. Conducted Susceptibility Induced Signal Susceptibility Radiated and conducted Susceptibility Radiated and conducted Emissions Lightening Induced Transient Susceptibility Lightening direct effects Electrostatic Discharge

 Open the catalog to page 8
RedBaron XP Galactica-9

Installation Manual AVE-RBXP-001-IM Issue 05 Technical Drawing

 Open the catalog to page 9
RedBaron XP Galactica-10

Installation Manual AVE-RBXP-001-IM Issue 05 Wiring Chart Use diagram below defining the wiring size depending on the current and the wire length. Make sure you add up the current for all connected lights. If current is not given, then divide the power by the voltage.

 Open the catalog to page 10
RedBaron XP Galactica-11

Installation Manual AVE-RBXP-001-IM Issue 05 Optic Simulation RedBaron XP Galactica – White AVE-RBXPW-001 Mod(1)

 Open the catalog to page 11
RedBaron XP Galactica-12

Installation Manual AVE-RBXP-001-IM Issue 05 Equipment Limitation RedBaron XP Galactica™ should only be powered by 9-36 VDC, typically a 14 or 28 volt aircraft battery. This article meets the minimum performance and quality control standards required by the technical standard order ETSO C96a. Installation of this article requires separate approval. Deviations This article deviates from the ETSO C96a by the usage of newer revisions of the following standards: SAE AS 8017 rev. B used instead SAE AS 8017 rev. A Care and Cleaning of Lights Aveo Engineering Aviation Lights are factory polished and...

 Open the catalog to page 12
RedBaron XP Galactica-13

Installation Manual AVE-RBXP-001-IM Issue 05 Connect the black wire to the ground (negative) leads of a power supply, then connect the yellow wire to the positive (+) leads on the power supply. The anti-collision light should start flashing. Connecting the blue wires from each AveoFlash light together (and not to the ground or positive terminals on the battery) should show that the lights are flashing together and indicates the synchronization feature is working properly. When installed on the aircraft, using the aircraft’s power (14 or 28 volts), the light will be at its maximum intensity. After...

 Open the catalog to page 13
RedBaron XP Galactica-14

Installation Manual AVE-RBXP-001-IM Issue 05 a. Circuit/Wiring Protection Each RedBaron XP Galactica series light features a Negative Temperature Coefficient (NTC) circuit that limits internal temperatures by attenuating operating current (with a corresponding reduction of brightness) when internal temperatures reach a certain threshold. This proprietary circuitry serves to protect the light itself, and associated aircraft wiring, against a thermal runaway condition. It's recommended that the operation of strobes without airflow be limited to avoid heat build up and this NTC circuitry feature...

 Open the catalog to page 14
RedBaron XP Galactica-15

Installation Manual AVE-RBXP-001-IM Issue 05 Figure 2: Bottom LEDs

 Open the catalog to page 15
RedBaron XP Galactica-16

Installation Manual AVE-RBXP-001-IM Issue 05 RoHS Compliance Statement Scope This statement clarifies Aveo Engineering’s compliance with European Union Directive 2015/863/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment ("RoHS") that took effect on June 4, 2015. The RoHS Directive restricts the sale of electronic equipment containing certain hazardous substances in the European Union including: Cadmium(Cd): 0.01% Mercury: 0.1% Lead(Pb) : 0.1% Hexavalent chromium (Cr6+) : 0.1% Polybrominated biphenyls (PBB): 0.1 %; Polybrominated diphenyl...

 Open the catalog to page 16
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.