  • Document Approval: The manual is established under an alternative procedure to DOA approved by EASA AP429. It applies to specific part numbers for Hercules Drop-In Landing and Taxi lights.
  • Amendment Record Procedure: The master copy is maintained electronically. Amendments result in a new issue number, approved by the Head of DO.
  • Effected Pages Procedure: Lists pages affected by amendments, with changes highlighted in yellow.
Installation Data
  • Product Info: The Hercules lights are environmentally friendly, using less power and being mercury and lead-free. They feature optimized optics and advanced LED power supply.
  • Wiring: Recommended wire size is 16 AWG. Specific wiring instructions are provided for different models.
  • Technical Specification: Includes details such as input voltage (9-36 V DC), current (3.2A at 28V), output power (90W), and ambient temperature range (-55°C to +85°C). The lights have overheat protection and a useful life of at least 30,000 flight hours.
  • Technical Drawing: Provides dimensions for various models.
  • Wiring Chart: Not detailed in the provided text.
  • Care and Cleaning of Lights: Lights should be polished with lamb’s wool and petroleum-based products should be avoided.
See more

Catalog excerpts

Hercules H30-1

Hercules H30 INSTALLATION MANUAL AVE-H30-002-IM © 2018 Aveo Engineering Group, s.r.o. All rights reserved. The information contained within this document must not be disclosed, copied or reproduced in whole or in part without prior written permission from Aveo Engineering Group, s.r.o. Distribution of this document shall only be as stated in Table 02 unless otherwise agreed by Aveo Engineering Group, s.r.o.

 Open the catalog to page 1
Hercules H30-2

INSTALLATION MANUAL Aveo HerculesTM AVE-H30-002-IM Issue 02 TABLE OF CONTENTS PART 0

 Open the catalog to page 2
Hercules H30-3

Aveo HerculesTM AVE-H30-002-IM Issue 02 INSTALLATION MANUAL Part 0 Manual Administration 0.1 Document approval This document has been established in accordance with an alternative procedure to DOA approved under EASA AP429. This installation manual is applicable for part numbers:     Hercules Hercules Hercules Hercules Drop-In Landing Drop-In Taxi LLP Taxi LLP Landing Peter Nezval Engineer, Aveo Engineering Group, s.r.o. Georg Hartl Head of DO, Aveo Engineering Group, s.r.o.

 Open the catalog to page 3
Hercules H30-4

Aveo HerculesTM AVE-H30-002-IM Issue 02 INSTALLATION MANUAL 0.2 Amendment Record procedure The master copy of this document shall be kept electronically as a read only document under the control of Aveo Engineering Group, s.r.o. as Master Copy. ALL amendments to this manual will initiate a raise of issue. ALL raises of issue will be given a sequential Alphabetic Issue Ident sequentially from 01 to 99 in Table 01 - Issue No: Column– Initial Issue of Document will be “01” ALL Issues of this document will be approved by Head of DO Effected Pages Initial Issue Cover picture changed (not marked) Addition...

 Open the catalog to page 4
Hercules H30-5

INSTALLATION MANUAL Aveo HerculesTM AVE-H30-002-IM Issue 02 Installation data 1.1 Product info Aveo Engineering introduces the exclusive next-generation Hercules™ Drop-In and external bracket (LLP) replacement for Legacy Lights. Environmentally Friendly The Hercules uses far less power than competitive products illuminated by mercury-arc, high intensity discharge, or halogen lamps, which means they help to reduce air pollution from carbon emissions. Mercury and Lead-free, this RoHS compliant environmentally-friendly technology helps reduce power consumption and the amount of hazardous waste entering...

 Open the catalog to page 5
Hercules H30-6

Aveo HerculesTM AVE-H30-002-IM Issue 02 INSTALLATION MANUAL Red (+) = Input (VCC) Blue (-) = Return (GND) Recommended wire AWG size: 16

 Open the catalog to page 6
Hercules H30-7

INSTALLATION MANUAL Aveo HerculesTM AVE-H30-002-IM Issue 02 1.3 Technical Specification 1. Number of LED: 30 2. Input voltage: 9-36 V DC 3. Input current: 3.2A at 28V ±10% 4. Output power: 90W 5. Transcend voltage: 2 seconds +80V 6. Under-voltage lockout: 9 VDC, not more 7. Over-voltage lockout: 36 VDC, not less 8. Ambient temperature: from -55°C to +85°C (from -67°F to +185°F) 9. Color and shade: cool white, 5000K – White 10. Lens: - Landing light version 12° viewing angle symmetrical beam - Taxi light version 40° x 20° viewing angle asymmetrical beam 11. Overheat protection, temperature dependent...

 Open the catalog to page 7
Hercules H30-8

INSTALLATION MANUAL Aveo HerculesTM AVE-H30-002-IM Issue 02

 Open the catalog to page 8
Hercules H30-9

INSTALLATION MANUAL Aveo HerculesTM AVE-H30-002-IM Issue 02 1.6 Care and Cleaning of Lights When you receive your Aveo Engineering Aviation Lights, they will have been factory polished and ready to install on the aircraft. If the lights require a deeper cleaning, they should be polished with a quality lamb’s wool sheet and can also be used for deeper polishing. Under no circumstances should any petroleum based product be used to clean the lights.