BCA - 1

Alt*ateq-aviation.comATEQ BCA Battery Charger Analyser (75 V - 40 Amps or 48 V - 60 Amps versions) + USER FRIENDLY INTERFACE ^ 1 UNIT FOR 2 BATTERIES (only for BCA 75 V - 40 Amps) ^ External Voltage measurement ^ Computer Management System available AIRCRAFT TEST INSTRUMENTS & BENCHES - GROUND SUPPORT EQUIPMENT

Open the catalog to page 1
BCA - 2

MCMS SOFTWARE FEATURES FUNCTION CHARACTERISTICS Charging phase - Constant or variable Intensity/Voltage - Adjustable from PC, profile, EXCEL file - On I constant, or variable, limit U max, -AV, time, temperature min and max, AT°/At - On U constant, or variable, limit I min, times AI (%), temperature min and max, AT°/At - Temp. protection probe type K, adjustable - Elements voltage measurements and stop or stand by on elements voltage Discharging phase - Constant or variable Intensity - Adjustable from PC, profile, EXCEL file - U min limit, time, temp. min and max, AT°/At - Temp. protection...

Open the catalog to page 2
BCA - 3

AVAILABLE ACCESSORIES 3/4 General Electrical characteristics Sector input: 100-240 VAC Monophased Temperature of use: 0-50°C (0-20°C without derating) Cooling: By forced ventilation Weight: ~26 kg Power supply characteristics at constant voltage (charging) Output voltage: 0-75 VDC per channel | 0-48 VDC per channel Regulation: 0.1 % for a variation of I from 10 to 90 % Stability: 0.1 % at full charge for 8H Power supply characteristics at constant current (charging) Output current: 0-40 ADC | 0-60 ADC Regulation: 0.1 % for a variation of U from 10 to 90 % Stability: 0.1 % at full charge for...

Open the catalog to page 3
BCA - 4

A FULL RANGE OF SERVICES DEDICATED TO YOUR PERFORMANCE OUTSTANDING SERVICE Global service & calibration support, 2-day calibration Multi-brand Calibration Service Demo unit rental Training Maintenance & Repair Free loan period Multi-brand Calibration Service Deep Discharge Up to 24 cells with a 1 Ohm resistance. Cells Measurement Cover to measure up to 24 Cells voltage. Souriau connector available on the front panel. ATEQ AVIATION EMEA Europe, Middle East, Russia, Africa + Custom software/Hardware Requests 30, rue des Dames 78340 Les Clayes-sous-Bois - France Phone: +33-1 30 80 10 20 Fax:...

Open the catalog to page 4

All ATEQ Aviation Division catalogs and technical brochures

  1. ADSE 746

    2 Pages

  2. EFCTB

    2 Pages

  3. ADSE 740

    2 Pages

  4. ADSE 744

    2 Pages

  5. ADSE 743

    2 Pages

  6. ADSE 650

    2 Pages

  7. ADSE 550

    2 Pages

  8. BA 1500

    2 Pages

  9. BC 1500

    2 Pages