WRA-101 - 1

Instruction Manual Before use, adjustment or maintenance, it is important to read this instruction manual very care fully. This manual must be stored in a safe place for any future reference that may be necessary. This ANEST IWATA spray guns kit complies to ATEX regulations 94/9/EC, Protection level: II 2 G X Suitable for using Zones 1 and 2. X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated. IMPORTANT This automatic spray gun should be operated only by an adequately trained operator for safe use and maintenance of the equipment. Any misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee. ANEST IWATA disclaims all responsibility for any accident or damage caused by failure observing the operational and safety procedures in this manual. In the interest of user friendliness, this manual contains information in a brief and concise form. For any additional information you may require regarding the automatic spray gun operations, or if any missing parts or any damage during transportation is found, or details of training courses, please contact your nearest ANEST IWATA Company (see last cover page). Be sure to observe warnings and cautions in this instruction manual. If not, it can cause paint ejection and serious bodily injury by drawing organic solvent. Be sure to observe following marked items which are especially important. Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property damage. Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the minimum necessary conditions. Follow national and local regulations regarding fire prevention, electricity and safety as well as your own company regulations. IMPORTANT SPECIFICATIONS Max. Operating air pressure: Noise Level (LAeqT): Air connection: Fluid connection: ANEST IWATA Europe S.r.l. Corso Vigevano, 46 - 10155, Torino (Italy) Direct Tel. +39 011 - 22 74 402 Fax +39 011 - 22 74 000 info@anest-iwataeu.com www.anest-iwataeu.com Max. Temperature: Atmosphere Air and fluid * Measuring point: 1m backwards from gun, 1,6 m height TECHNICAL SPECIFICATIONS European Sales Branches: ANEST IWATA Italia S.r.l. Corso Vigevano, 46 - 10155, Torino (Italy) Tel. diretto +39 011 - 24 80 868 - Fax: +39 011 - 85 19 44 info@anest-iwata.it www.anest-iwata.it ANEST IWATA France 25 rue de Madrid - 38070 St Quentin Fallavier - France Tél. +33 (0)4 - 74 94 59 69 - Fax +33 (0)4 - 74 94 34 39 info@anest-iwata.fr www.anest-iwata.fr ANEST IWATA U.K. Unit 10 Little End Road - Eaton Socon St. Neots - CAMBRIDGESHIRE PE19 8JH Tel.: +44 (0) 1480 40 54 19 Fax: +44 (0) 1480 21 76 10 enquiries@anest-iwata.co.uk www.anest-iwata.co.uk Air pressure at gun inlet bar (PSI) Atomizing air Fan air Pattern width mm(in) Manufactured by: ANEST IWATA Corporation 3176,Shinyoshida-cho, Kohoku-ku, Yokohama, 223-8501 Japan

Open the catalog to page 1
WRA-101 - 2

SAFETY WARNINGS FIRE OR EXPLOSION HAZARD TROUBLESHOOTING Spray Pattern Problems Fluttering 1. Sparks and open flames are strictly prohibited. Paints can be highly flammable and can cause fire. Avoid any ignition sources such as smoking, open flames, electrical goods, etc. 2. Fully tighten joint section. 1. Paint buildup on air cap partially clogs horn holes. Air pressure from both horns differs. 1. Remove obstructions from horn holes. But do not use metal objects to clean horn holes. 3. Securely ground spray gun. Use air hose with built-in ground wire or use grounded gun stay. Ground...

Open the catalog to page 2
WRA-101 - 3

SPARE PARTS LIST CAUTION - Use clean air filtered through air dryer and air filter. If not, dirty air can cause painting failure. - When you use this gun for the first time after purchasing, clean fluid passages spraying thinner to remove rust preventive oil. If not, remaining preventive oil can cause painting failure such as fish eyes. - Use two-way or three-way solenoid valve of more than ø 4 inner dia. cross-sectional area and air hose of over ø 6 inner dia. and less than 10m length. If not, small dia. of solenoid valve and longer air hose between three-way solenoid valve and gun can...

Open the catalog to page 3
WRA-101 - 4

Paint pump Adjust operating air pressure from 3 to 4 bar (43 to 57 PSI). Air Regulator 3-way solenoid valve Air pressure for atomizing or fan, varies according to spray conditions, adjust as specified on above specifications table. NOTE: Valve orifice inside two-way or three- way solenoid valve should be minimum 4mm (0.157 in) and also operating air hose length should be within 10m (32.8ft) with the inner diameter more than 6mm (0.236in) to avoid delayed operation and any kind of Air Regulator 2-way solenoid valve Paint flow meter NOTE: Using air hose 12 m (39.4 ft) long, the inner diameter...