Catalog excerpts

Angle of Attack Transducer DESCRIPTION AMETEK Aerospace Angle-of-Attack (AOA) transducers and the Stall Warning Systems which incorporate them are precision sensing devices that combine design simplicity, versatility, and component commonality. The result is reliable angle-of-attack and stall warning information for the pilot. Developed originally to meet stringent military requirements, AMETEK AOA transducers, or vanes, met the challenge and went on to establish a reputation for in-service reliability. The safety factor is a consideration every pilot expects and one every aircraft should provide. At AMETEK, the safety factor is paramount; safety is engineered into every product. Emphasis on safety in design and performance has been the keystone to our success. Features include high reliability, single/dual output devices such as synchro, resolver, and potentiometer, temperature compensated damping, and a reliable selfregulating, deicing/anti-icing vane heater design. AMETEK’s engineering has been on the leading edge of aerospace technology for decades. Program by program, AMETEK’s reputation for innovative product design and development has been built on an extensive line of reliable, high technology products. AOA and Stall Warning components offer ease of maintenance and conform to all applicable FAA, TSO, and military specifications. FEATURES • TSO C-54 Certified • Multiple Outputs for Redundant Stall Warning and/ or Ground Proximity Windshear Systems • Port and Starboard AOA Transducers Are Interchangeable • Self-regulating Vane Heaters for Deicing and Anti-icing • Damping to Minimize the Effect of Turbulent Flutter • Field Repairable APPLICATIONS • Business/Commuter Aircrafts: Metroliner, Merlin, Challenger, Learjet, and Falcon Jet • Commercial Aircrafts: B727, B737, B747, B747-400, DC-9, DC-10, MD-11 • Military Aircrafts: C-1, C-5, C-17, B-1, C-141, F-5, T-38, and CF-117
Open the catalog to page 1
SPECIFICATIONS Angular Range: +30O typical. Other ranges available. Total Output Accuracy: +0.25O at 90 knots Vane Heater: 28 VDC at 270 W or 115 VAC, 400 Hz ELECTRICAL CHARACTERISTICS Output: 1 or 2 synchros, resolvers, RVDT, or potentiometric wirewound or film Excitation Voltage: 26 V or 11.8 V at 400 Hz Vane Heater: 270 W at 28 VDC or 115 VAC, 400 Hz Scale Factor: Series 25147A: 36 ohms per degree of AOA Pre-Flight Self-Test Excitation/Pre-Position: Series 2568A: Two discrete angles (4.5O, 12.5O) per side Self-Test Excitation: Series 2568A: 115 VAC at 400 Hz ENVIRONMENTAL CHARACTERISTICS...
Open the catalog to page 2All Ametek Fluid management systems catalogs and technical brochures
-
8TJ167 Mass Fuel Flowmeter
2 Pages
-
8TJ126 Mass Fuel Flowmeter
2 Pages
-
SOI Pressure Transducers
2 Pages
-
Solid State Pressure Switch
2 Pages
-
Fluid Densitometer
2 Pages
-
Fuel Gauging Systems
2 Pages
-
Transient Suppressor Unit
2 Pages
-
Electric Harness Assemblies
2 Pages
-
Fluid Temperature Sensors
2 Pages
-
Multi-Axial Accelerometers
2 Pages