Product catalog summary
Compliance with Standards
The ACE3 unit is certified to FAA standards AC 150/5345-10 and ETL certified. It also complies with insulation resistance standards as per AC 150/5340-26 Chapter 3, Section 2, para. 27.
Overview
The ACE3 distributed control and monitoring unit (DCMU) by ADB Safegate is designed for full L-827/L-829 monitoring, either as part of an Airport Lighting Control and Monitoring System (ALCMS) or as a standalone unit. It is versatile, capable of controlling any constant current regulator (CCR) or controlled element, regardless of the manufacturer. The ACE3 can be configured in various forms: as an internal mount in a CCR, a Combo Box Assembly, or a wall-mounted I/O ACE for non-CCR components.
Features and Capabilities
The ACE3 supports up to seven expansion cards, each with eight interface points, allowing for extensive input/output configurations. It is microprocessor-based, ensuring communication, control commands, and fail-safe functionality. The ACE3 is compatible with previous generations of ADB Safegate systems and can be integrated into existing networks.
Theory of Operation
The ACE3 is part of a distributed control system, offering advantages such as cost-effectiveness, expandability, and ease of maintenance. It communicates with the airfield lighting control network to execute remote commands and can be daisy-chained for system expansion. The ACE3 is backward compatible with older systems and supports both wired and wireless communication options.
Communication
Each ACE3 unit has a unique communication address for directing commands and reporting status. It connects to redundant networks via RS-422 or Ethernet ports, ensuring real-time communication even if a network connection fails. Wireless networking is also available for diagnostics and mobile applications.
Interface
The ACE3 includes an input/output interface for full CCR control and monitoring. It supports various configurations for monitoring external events and can be expanded for additional monitoring capabilities.
Fail-safe Functionality
The ACE3 includes a fail-safe feature to maintain airfield lighting operation during ALCMS failures. It offers different fail-safe modes, including Latching, Simple, and Smart modes, to suit airport requirements.
Insulation Resistance Monitoring
The ACE3 can automatically test field circuit insulation resistance, with data archived locally and forwarded to the ALCMS for trend analysis.
Graphics User Interface (GUI)
The ACE3 features a 7-inch touchscreen GUI displaying output data, brightness steps, power status, communication status, and more. It includes a localized event database for viewing alarms and warnings.
Specifications
The ACE3 operates on 24 VDC or 95-265 VAC, with a maximum input power of 12 VA. It functions in temperatures from -10 to +55 °C and altitudes up to 10,000 feet. Dimensions vary based on configuration, with options for wall mount, internal mount, and Combo Box.
See more

Catalog excerpts

Ace3-1

CONTROL & MONITORING ACE3 L-827/L-829 Advanced Control Equipment Compliance with Standards FAA: expandability, ease of maintenance, ease of installation, interchangeable parts, and ease of troubleshooting. In a distributed control scenario, each ACE3 unit is locally installed at or near a controllable item (CCR, Generator, ATS, etc.). Each ACE3 would, in turn, talk with the airfield lighting control network and execute remote lighting commands. Multiple ACE3 units can be daisy-chained together, making system expansion very easy. Monitoring: Certified to AC 150/5345-10 (Current Edition). ETL Certified. Insulation Resistance: AC 150/5340-26 Chapter 3, Section 2, para. 27. The ACE3 is a universal device that can be used to control any type of CCR and/or controlled element regardless of the manufacturer. Printed circuit boards are mounted inside a small, rugged environmental enclosure that can be mounted on the wall or integrated into the door of an ADB Safegate L-828 CCR. ADB Safegate's ACE3 distributed control and monitoring unit (DCMU) provides full L-827/L-829 monitoring in conjunction with an Airport Lighting Control and Monitoring System (ALCMS), or it can be used as a stand-alone unit for local monitoring. The ACE3 is a universal device that can be used to control any type of constant current regulator (CCR) and/or controlled element regardless of the manufacturer. Each ACE enclosure is installed locally at each device that requires control and/or monitoring in the airfield lighting electrical vault. The ACE3 is ADB Safegate's third generation distributed control/ monitor system. ACE3 network communications are compatible with ADB Safegate's first and second generation system. Thus ACE, ACE2, and ACE3 units can be connected on the same distributed network. The ACE3 is also backward compatible with a Liberty DCMU installation. The ACE3 unit can be packaged as a CCR internal mount, a Combo Box Assembly, and a wall-mounted I/O ACE. • The ACE3 internal mount is integrated inside an ADB Safegate L-828 CCR. Installing the ACE unit converts it into an L-829 CCR. Each of the ACE3 units connected to a CCR or other controllable device will have a unique factory set number and a field programmable communication address. This address is used by the ADB Safegate L-890 ALCMS to direct lighting commands to the corresponding ACE3, which in turn executes the commands and returns the operational status of the element back to the ALCMS. • The Combo Box Assembly is a wall-mounted version that houses the ACE3 unit, IRMS board, and CVM2 (Current and Voltage Monitoring Unit Gen. 2). • The I/O ACE3 is a wall-mounted unit that is used to control and monitor any non-CCR components, such as generators, ATS units, Circuit Selectors, etc. Each ACE3 is connected to redundant communication networks via either two RS-422 serial communication ports or two Ethernet ports located on the main printed circuit board. The I/O ACE3 unit has the ability to accept a combination of up to seven (7) expansion cards, either input or output, to meet the I/O needs of the control system. Each expansion card contains eight (8) interface points, each point with its own dedicated common. This, in addition to the five (5) outputs and three (3) inputs available on the primary Default Card, allows the ACE3 to connect up to 61 outputs, 59 inputs, or a combination inputs and outputs to suit the individual control needs of the airport. The ACE network is comprised of a communications server and all the daisy-chained ACE units in the lighting vault. All ACE devices can be connected to the same network. The communications server stays in constant communication with all the different ACE units in both networks while at the same time staying in constant contact with the main ALCMS network. This communications protocol dictates that the local ACE3 store all data and parameters specific to the controlled element. This characteristic frees up the ALCMS computers from having to store the parameters for each of the controlled elements. This results in real-time communication between all ACE units and the rest of the L-890 ALCMS, even if a network connection fails in one of the ACE units. Each CCR and controllable item is connected to an ACE3. The ACE3 is a microprocessor-based module that includes all of the communication, control commands, input/output interface, and failsafe functionality for the controlled element. The ACE3 also provides an 802.11 wireless networking option, which can provide a wireless communication backup and can be used for diagnostics and future mobile application interaction. The Advanced Control Equipment (ACE™) is a primary component of ADB Safegate's airfield lighting distributed control system. Distributed control technology has many advantages over traditional central control, including but not limited to: cost-effectiveness, system

 Open the catalog to page 1
Ace3-2

CONTROL & MONITORING Interface The ACE3 incorporates an input/output interface that supports full FAA L-827/L-829 CCR control monitoring capabilities. The pluggable terminal blocks provide an easy-to-service point of connection. The latching output relays can be configured to control CCR brightness steps or simple ON/OFF control as required by the controlled element. The input lines can be configured to monitor any external event that is determined by a discrete dry contact closure. Some examples include generator monitoring, monitoring of Automatic Transfer Switch position, and control of Circuit...

 Open the catalog to page 2
Ace3-3

CONTROL & MONITORING 1 Type C = Combo box I = I/O Output Expansion Modules 0-72 Specifications Input Voltage: Dimensions Wall Mount: Notes 1 Only available with Combo Box Type 2 Total number of Input and Output cards cannot exceed 7 Product specifications may be subject to change, and specifications listed here are not binding. Confirm current specifications at time of order.

 Open the catalog to page 3

All ADB SAFEGATE catalogs and technical brochures

  1. RELIANCE

    6  Pages

  2. L-88 series

    4  Pages

  3. AXON

    3  Pages

  4. Aglas

    6  Pages

  5. Optamos

    4  Pages

  6. One control

    4  Pages

  7. Infomax

    4  Pages

  8. Diflis

    4  Pages

  9. Declos

    4  Pages

  10. Acemax

    4  Pages

  11. FAP

    3  Pages

  12. ALSF-SSALR

    6  Pages

  13. SYS 800D-S

    6  Pages

  14. SL-AC-AS-I

    2  Pages

  15. DTS-LP/DTC-LP

    4  Pages

  16. LEAP

    4  Pages

  17. BPE

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.