GMS800 FIDOR® TOTAL HYDROCARBON ANALYZER TRANSIC100LP LASER OXYGEN TRANSMITTER The good nose for oxygen Continuous monitoring of hydrocarbon emissions Gas transmitter
カタログの1ページ目を開く
TRANSIC100LP: Laser oxygen transmitter Simple, fast and low maintenance Process parameters are best measured where they are relevant and present in an unaltered state – directly in the process. "In-situ measuring technology" or "Inline measuring" are the phrases used. The process parameters are determined under process conditions. The TRANSIC100LP is an oxygen transmitter that measures in-situ or "inline". The sensor is designed as a measuring probe. This ensures that the lens system in the transmitter is always optimally aligned and installation is very simple. The measuring task can be...
カタログの2ページ目を開く
The TDLS Tunable Diode Laser Spectroscopy is primarily used in high-end gas analyzers and is characterized by its highly selective measurement capability. The oxygen properties are used for O2 measurement: That means O2 atoms in the near infrared range are stimulated at specific wavelengths. A laser diode modulates the radiation precisely over an absorption peak. The high-energy radiation transfers energy to the O2 atoms and the signals becomes weaker. In the measuring probe, the laser beam hits the O2 atoms and is weakened according to the concentrations of oxygen present there. A receiver...
カタログの3ページ目を開く
TRANSIC121LP and TRANSIC151LP: Measuring oxygen in potentially explosive atmospheres An explosion can only occur when all three elements (fuel, an ignition source and oxidant), referred to as the explosion triangle, are present. The primary explosion protection prevents the simultaneous occurrence of a fuel and an oxidant. If flammable substances cannot be avoided, no oxidants may be present. Commission, 1994) for devices and 1999/92/EC (European Commission, 1999) for operation (ATEX Directive) and the harmonized standards, or NEC 500 and NEC 505 in the USA. For use in potentially explosive...
カタログの4ページ目を開く
Dust: II 2 D Ex ibtb IIICTS5°C Db Dust: II 2 D Ex ibtb INCT85°C Db Subject to change without notice
カタログの5ページ目を開く
THE GOOD NOSE FOR OXYGEN Additional information Product description Measuring the oxygen in the process can be quite simple. The TRANSICIOOLP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure 02 reliably. A tech- nology more common in the world of • 02 transmitter based on high-perfor- mance laser spectroscopy (TDLS) atmospheres (FM, ATEX and lECEx • Measurement directly in-situ or extractive using a sample gas cell Your benefits • Measures in real-time directly in the • Easy installation and operation • Self-diagnostics with maintenance...
カタログの6ページ目を開く
Fields of application • Monitoring of inert gas blanketing in tanks and vessels • O2 measurement in process gases • Measurements in potentially explosive atmospheres • Process monitoring in fermenters and bioreactors • Room air monitoring • Quality monitoring for the production of technical gases • Replacement of extractive paramagnetic oxygen analyzers and electrochemical cells Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the...
カタログの7ページ目を開く
Electrical connection Voltage 24 V DC TRANSIC151LP: 21.6 ... 26.4 V For ATEX/IECEx version via TSA151 power supply, a PELV power supply is mandatory Current consumption Power consumption Corrective functions Test functions Adjustment with ambient air or test gases Contamination check
カタログの8ページ目を開く
Ordering information Our regional sales organization will help you to select the optimum device configuration. Type code TRANSIC111LP Version A With flange for in-situ installation, <0.5 bar, O2 measuring range of 0 ... 25 vol.-% B With wall bracket for ambient air measurement, O2 measuring range 2 ... 25 vol.-% C With sample cell and wall bracket, PN10, O2 measuring range 0 ... 25 vol.-% D With flange for in-situ installation, <0.5 bar, O2 measuring range 0 ... 100 vol.-% [1] E With sample cell and wall bracket, PN10, O2 measuring range 0 ... 100 vol.-% [1] F With flange for in-situ...
カタログの9ページ目を開く
[1] With certificate for oxygen service [2] For use in clean gas only or with a sample cell [3] Not selectable for the O2 measuring range 0 ... 100 vol.-%. Not recommended for wet gas near dew point. [4] Can be reconfigurated in the field [5] Factory setting: 0 … 25 vol-% O2 [6] Can be reconfigurated in the field (requires a serial interface and a terminal program on PC) [7] Selectable only for the output range of 4 ... 20 mA [8] Factory setting: 10 vol-% O2 [9] PTFE filter for reference gas inlet recommended TRANSIC121LP Version A With flange for in-situ installation, < 0.5 bar, O2...
カタログの10ページ目を開く
TRANSIC151LP Version A With flange for in-situ installation, < 0.5 bar, O2 measuring range of 0 ... 25 vol.-% B With wall bracket for ambient air measurement, O2 measuring range 2 ... 25 vol.-% C With sample cell and wall bracket, PN10, O2 measuring range 0 ... 25 vol.-% F With flange for in-situ installation, PN10, O2 measuring range of 0 ... 25 vol.-% G With weld-on nozzle for in-situ installation, PN10, O2 measuring range 0 ... 25 vol.-% H With 3’’ clamp connection for in-situ installation, PN10, O2 measuring range 0 ... 25 vol.-% Filter type 1 No filter [1] 2 Stainless steel mesh 3 PTFE...
カタログの11ページ目を開く
TRANSIC100LP Gas transmitters only in a non-hazardous area! [6] Selectable only for the output range of 4 ... 20 mA [7] Factory setting: 10 vol-% O2 [8] For connection between transmitter and power supply TSA151 only SICK Ex i cabel have be used [9] PTFE filter for reference gas inlet recommended [10] Connection to PC should be done only in a non-hazardous area! Use SICK service interface cables only. [11] Do not operate TRANSIC151LP transmitter without TSA151 power supply! Dimensional drawings (Dimensions in mm (inch)) TRANSIC100LP with flange adapter for process measurements below 0.5 bar...
カタログの12ページ目を開くSICK SENSOR INTELLIGENCEのすべてのカタログと技術パンフレット
-
REGISTRATION SENSORS
24 ページ
-
CLV63x, CLV64x, CLV65x
102 ページ
-
WTB16 Bluetooth®
135 ページ
-
WE9LC-3_A71
3 ページ
-
Safety Switches
20 ページ
-
Proximity Sensors
324 ページ
-
Dust measuring devices
172 ページ
-
Distance Sensors
404 ページ
-
Vision
124 ページ
-
Top-Products from SICK
556 ページ
-
Fluid Sensors
243 ページ
-
Registration Sensors
276 ページ
-
Magnetic Cylinder Sensors
164 ページ
-
IDENTIFICATION SOLUTIONS
24 ページ
-
ConVer
12 ページ
-
Encoders
788 ページ
-
WT100-2 energetic
47 ページ
-
Photoelectric Sensors
949 ページ
-
G6 - Global Sensor
20 ページ
-
Hand-Held Scanners IDMx
48 ページ