

カタログの抜粋

Efficient measurement of SO2, NO, NO2, NH3 as well as TRS components in the Kraft pulp process
カタログの1ページ目を開く
In-situ gas analyzer GM32: For emissions and process gases The tried-and-tested in-situ GM32 analyzer from SICK – optimized for non-contact measurement in emissions plants as well as for process gases – is available in several versions: a standard version, an Atex version and with optimized analysis technology for TRS measurement in the Kraft pulp industry. Direct in-situ measurement With the GM32 in-situ gas analyzer, your control technology systems are able to work with actual values in "real time". This is because it measures reactive gases including pressure and temperature in-situ, in...
カタログの2ページ目を開く
Open GMP measuring probe Measuring probe version GM32 is available with two measuring probe types: with open measuring path •• GPP gas diffusion probe Sender/receiver unit Cross-duct version The sender/receiver and reflector units in the GM32 are installed adjacently to each other at the measuring site. Reflector unit Sender/receiver unit Atex version GM32 Ex with GMP measuring probe Open GMP measuring probe Sender/receiver unit in Atex design Measuring probe version Cross-duct version Designed for ATEX zones This version proves its strengths: The cross-duct version is suitable for the...
カタログの3ページ目を開く
In-situ measurement in ATEX zones: a new solution for familiar tasks GM32 gas analyzers with in-situ measuring technology have a long track record both in emissions monitoring as well as in process control applications. Now the rugged GM32 is also available in an ATEX version as the GM32 Ex, with cross-duct and measuring probe versions for gas temperatures up to 650°C, for example, for use in the chemicals industry or refineries, but also for measuring tasks in the natural gas or crude oil industry as well as emissions monitoring supporting sulfur recovery plants or FCC plants. A wide scope...
カタログの4ページ目を開く
Simple, precise, cost-effective: TRS emissions safely under control The first and only direct TRS measurement in the Kraft pulp process: GM32 TRS-PE (PE = Pulp Emission) from SICK. TRS measurement success in the Kraft pulp industry UV spectroscopy – the optimal measuring technology Lime kilns and black liquor recovery boiler for the source for TRS components in Kraft pulp plants. The limit values for these emissions are strictly regulated by the authorities and are typically set between 5 ... 30 mg/m3 (3 ... 20 ppm). Depending on restriction, hydrogen sulfide (H2S) must be monitored alone...
カタログの5ページ目を開く
Monitoring and control of flue gas in purification plants The in-situ GM32 analyzer with its optimized measuring technology is suitable for nitrogen oxide measurement for controlling catalytic processes in flue gas denitrification and desulfurization plants. The GM32 is the best choice, especially in situations where rapid measurement is required directly in the gas duct, even under high dust loads or where saturated sample gas is expected. Flue gas denitrification plants – fast, unaltered measurement Environment protection laws demand reduction of nitrogen oxide (NOx content) in flue...
カタログの6ページ目を開く
Desulphurization plants and emissions measurement Desulphurization plants (DeSOx) use, among other things, wet scrubber systems in order to spray the flue gas with a calcareous solution after the dust has been removed. This process causes the sulfur oxides in the flue gas to react and be converted to calcium sulfite or sulfate. These products are then removed from the process by dehydration. Alternatively, compressed air can be added to the sulfite sludge causing the calcium sulfite to oxidize into gypsum. The GM32 from SICK has also proven itself in such process control applications as...
カタログの7ページ目を開く
Measure aggressive gases directly and quickly – even in ATEX zones Product description The GM32 in-situ gas analyzer measures SO2, NO, NO2 and NH3, as well as TRS components in Kraft pulp processes including pressure and temperature in the gas duct. Direct, fast and without gas sampling and transport. This means control systems are able to work with actual values in real time. Due to self-monitoring, the measured values are reliable. In case of deviations an early warning will be shown. For emission measurement of SO2 and NO, GM32 is tested for suitability according to European standard EN...
カタログの8ページ目を開く
Fields of application •• For monitoring and control in flue gas purification, such as denitrification plants, desulfurization plants and converters. •• Emissions monitoring according to EU directives or local •• Monitoring tasks, for example, in nitric acid and ammonia production processes •• TRS emissions monitoring in the Kraft pulp industry •• Monitoring of landfill gases Detailed technical data System System: standard and Atex version Description Approved in-situ gas analyzers for emissions monitoring Measured value TÜV-approved measured values Maximum number of measured values 4 (plus...
カタログの9ページ目を開く
ATEX approvals ATEX Electrical safety Enclosure rating Standard: IP 65, IP 69K Atex version: IP 65 Via integrated operating unit or SOPAS ET software Corrective functions Internal correction of contamination Test functions Internal zero point check Control cycle for zero and reference point acc. QAL3 The scope of delivery depends on application and customer specifications System: TRS–PE In-situ gas analyzers for TRS monitoring in Kraft pulp processes Measured value Maximum number of measured values 8 (plus process temperature and pressure) 8 Measurement principle Chemometric data analysis 0...
カタログの10ページ目を開く
Corrective functions Test functions Internal zero and reference point check Internal correction of contamination The scope of delivery depends on application and customer specifications Sender/receiver unit Sender/receiver unit: standard version Description Measurement system analyzer unit Ethernet (service and OPC interface) Via integrated operating unit Sender/receiver unit: ATEX version Description Measurement system analyzer unit Ethernet (service and OPC interface) Via integrated operating unit Measuring probe Open measuring probe (GMP) Description Measuring probe in open version with...
カタログの11ページ目を開くSICK SENSOR INTELLIGENCEのすべてのカタログと技術パンフレット
-
REGISTRATION SENSORS
24 ページ
-
CLV63x, CLV64x, CLV65x
102 ページ
-
WTB16 Bluetooth®
135 ページ
-
WE9LC-3_A71
3 ページ
-
Safety Switches
20 ページ
-
Proximity Sensors
324 ページ
-
Dust measuring devices
172 ページ
-
Distance Sensors
404 ページ
-
Vision
124 ページ
-
Top-Products from SICK
556 ページ
-
Fluid Sensors
243 ページ
-
Registration Sensors
276 ページ
-
Magnetic Cylinder Sensors
164 ページ
-
IDENTIFICATION SOLUTIONS
24 ページ
-
ConVer
12 ページ
-
Encoders
788 ページ
-
WT100-2 energetic
47 ページ
-
Photoelectric Sensors
949 ページ
-
G6 - Global Sensor
20 ページ
-
Hand-Held Scanners IDMx
48 ページ