カタログの抜粋

Automatic Mobile Weather Station for military usage Military class equipment Military design optional Aviation weather observation Climatological observation Synoptic observation Radiation & environmental monitoring The MicroStep-MIS AMS 111 II system is designed for standard or mobile meteorological stations, as well as for the applications in areas where the commercial power or communication networks are limited or do not exist. Modular design The AMS 111 II interfaces with various sensors and telecommunication devices. Embedded with the state-ofthe-art software, AMS 111 II is a reliable and cost-effective solution for meteorological and environmental monitoring. Addressable RS-232/485 converters allow to integrate AMS 111 II with intelligent sensors, displays and computers to common virtual monitoring station with individual components located within 1 km. Handy Secure digital memory cards allows easy distribution of data, configuration or firmware updates between AMS stations, as well as from/to the managing PC systems. Consisting of the building blocks interconnected by a RS485 system bus, AMS 111 II serves as a modular and flexible platform for construction of various measuring and logging systems, which include AMS 111 II modules, intelligent sensors, displays and PC-s. System flexibility allows wide application range from simple compact systems to multipurpose stations. 24-bit A/D conversion and software features such as data validation and quality control ensure the accuracy of the measured data. System supports data output to RS-232/485 lines, modems and cellular phones (SMS, GPRS), radio-modems and satellites. PPP protocol support makes AMS 111 II Internet-ready. User-friendly software applications allow easy and comfortable system configuration, setup and maintenance also remotely via modem/PPP connection. The AMS 111 II Data Logger system may be supplied with or without touch screen graphics display, and optionally with GSM (wireless) or PSTN modem - depending on user’s requests. Two sizes of special housing boxes are optional. Mainboard - the board for interfacing sensors and/or communication devices Optional extension modules PL-DSP Touch screen display Modem module (wireless GSM/GPRS modem) (128 x 64 graphic display with 32-button touch screen) (leased line/dial-up modem) The typical AMS 111 II is usually housed in weather-proof enclosure, which includes mainboard, display (optional), sensor-connection terminal, AC adapter or battery power supply (optional), backup battery (optional), and pressure sensor (optional). MicroStep-MIS, www.microstep-mis.com © 2014. All specifications subject to change without p
カタログの1ページ目を開く
The AMS 111 II Data Logger board is running the MicroStep-MIS multi-tasking real-time executive. The add-on external secure digital card with the data capacity up to 2 GB is sufficient for the several months in the typical applications. Analog inputs • 22 x precise differential inputs, ±2.5 V to ±19.5 mV • Resolution: 24 bit • Measurement period: from 1 s Accuracy • Voltage meassurement 0.031 % • Resistance meassurement 0.042 % • 5 x additional analog inputs 0 to 5 V / 0 to 2.5 V (optional) • ±2.5 mV or other range (on special request) Digital inputs • 12 x digital input, 0 V to 20 V •...
カタログの2ページ目を開く
Wind Direction Relative Humidity Measurement range Response time Temperature Wind Speed Measurement range depends on Data Logger Response time Outputs Digital outputs 4 x digital output, open collector 35 V / 1 A Power outputs 4 x switching power supply up to 1.5 A Battery charger Integrated automatic battery charger. Maximal charging current 2 A. Battery monitoring with full charge state and cut off voltage. Pressure Sensor −35 °C to +70 °C (without heating) −40 °C to +70 °C (with heating) Storage temp. Minimum pressure limit Operating temp. Windsonic Windsonic M Response time Pressure...
カタログの3ページ目を開く
Sensors and Devices Pressure Sensor - optional Digital Barometer Pressure range Total accuracy Long-term stability Overpressure limit 4000 hPa (not affecting sensor calibration) Burst pressure limit Rain Gauge Aperture Voltage for heating (MR2H only) Performance of heating elements (MR2H only) Operating temperature MR2 MR2H Accuracy (at rainfall intesnity*) 0 °C to +60 °C (without heating) −30 °C to +60 °C (with heating) <1 % (20 mm/h) <2 %( 60 mm/h) <10 % (200 mm/h) <2 % (500 mm/h) MR2HC only** * Above mentioned accuracy is valid for liquid precipitation only. ** This option is possible...
カタログの4ページ目を開く
Laser Ceilometer Measurement range up to 3 layers Measurement interval greater of ±10 m (30 ft) or ±1 % of height (against reflector) Laser safety Class 1 laser product (SS-EN60825) Power supply Operating temp. Portable Mast Unfolded dimensions Packed dimensions Cross arms arm for wind sensors arm for meteorological sensors solar panel holder, antenna holder aluminium alloy Field PC Small, high-reliable laptop-class personal computer with special shock-resistant construction, recommended for usage in places where frequently field transportation or working in extreme weather conditions is...
カタログの5ページ目を開く
Automatic Mobile Station Example Meteorological Sensors Digital Barometer Backup Battery M SB181 Contact us for more information Cavojskeho 1, 841 04 Bratislava, Slovak Republic tel.: +421 2 602 00 100, fax: +421 2 602 00 180 www.microstep-mis.com, info@microstep-mis.com © 2014, All specifications subject to change without prior notice Monitoring and Information Systems
カタログの6ページ目を開くMICROSTEP-MISのすべてのカタログと技術パンフレット
-
MMR-116
3 ページ
-
RT1
1 ページ
-
IMS4 ATIS / VOLMET
4 ページ
-
RHT175
2 ページ
-
IMS4 MetReporter
4 ページ
-
IMS4 RVR
2 ページ
-
IMS4 ARWIS
4 ページ
-
MM10
2 ページ
-
IMS4 AWOS
6 ページ
-
IMS4 Model Suite
6 ページ
-
IMS LITE
2 ページ
-
SWS-200
2 ページ
-
IRS31 Pro
1 ページ
-
IMS4 LLWAS
4 ページ
-
IMS4 AWDSS
4 ページ
-
IMS4 ARWIS 2014
4 ページ
-
IMS CLDB
8 ページ
-
MWD-30A
1 ページ
-
IMS4 AMS 111 II
4 ページ
-
SAWS 111
2 ページ
-
RHT75
1 ページ
-
PT100D
1 ページ