ALSF Flasher System
1 / 2ページ

{{requestButtons}}

カタログの抜粋

ALSF Flasher System - 1

ALSF Flasher System Compliances: FAA AC 150/5345-51 SSALR (Type I) ICAO ANNEX 14 Applications Precision approach to runway in visibility conditions where the runway visual range (RVR), is less than one-half mile requiring steady-burning approach lights with sequence flashing lights. The system consists of a master controller for monitoring and individual flashing lights that can be incorporated with steady burning lights to create various types of approach light systems such as the classic 21-position ALSF-1 or ALSF-2. Flashhead and power converter may be mounted as one unit or individually to meet local terrain needs. Inset (surface mount) flashers are also available. Other parts of the system, such as steady burning lights, towers, light bases, transformers and regulators must be ordered separately. Features ■ ETL Tested and Verified ■ Real-time dynamic fault detection and isolation ■ Elapsed time metering (user-setable alarms) ■ Standard input voltages 60 Hz 120 V, 240 V, 50 Hz-230 V ■ Micro-processor control ■ Transient protection ■ Monitoring and dimming capability ■ Local and remote control operation ■ High-intensity default and failure detection, and caution indication Fixture Type: Insert Number of Flashers Needed (30 Maximum) Input Power: NEMA 4 outdoor cabinet with locking provisions -55°C to +55°C operation Remote tower and vault control panels available Computer-control compatible (dry contacts) 120 Flashes per minute (factory calibrated) LED display FTC183 25 Watts, Average power consumpiton Can be installed up to 2500' from the approach system Current operated unit uses 300W transformer (not supplied) Input Power: - 1 = Voltage operated with internal controller 3 = Current (series) operated Flashing Lights:- FTS SERIES products are manufactured by Flash Technology, Franklin, TN.

カタログの1ページ目を開く
ALSF Flasher System - 2

Dimensions: Instruction Manual: Shipping Weight: Inches (mm) FTC 183 / FTC 435 Master Flasher Timer Power Supply 29lbs.. 25 lbs.. BOTTOM VIEW Standard Sequence Flasher System Components Item Part Number Fuse, Power, MDL2A 4900342 Renewal Parts Description Part Number Description Part Number Home Office: United States - +1 860-683-4300 International Offices: Canada • China • Dubai • Mexico • Brazil 3.13

カタログの2ページ目を開く

EATON CROUSE-HINDSのすべてのカタログと技術パンフレット

  1. PRO III TCL

    2 ページ

  2. PRO APF MIRL

    2 ページ

  3. PRO III TOL

    2 ページ

  4. PRO III SBGL

    2 ページ

  5. PRO III IRGL/ISBL

    2 ページ

  6. PRO APF AGS

    16 ページ

  7. AGS-LED

    4 ページ

  8. AGSF-LED Sign (L)

    4 ページ

  9. REIL-LED

    1 ページ

  10. AV07

    2 ページ

  11. PRO Command ALCMS

    6 ページ

  12. AV-LC

    1 ページ

  13. UEL - UTILITY LED

    2 ページ