Premium Temperature Calibrators (Dry block) PTC200: -55 to 200°C (-67 to 392°F) PTC700: RT to 700°C (RT to 1292°F) The Druck PTC200 and PTC700 series of Premium Temperate Calibrators are characterised by their unparalleled performance and outstanding ease of operation. By means of the intuitive menu structure, all necessary inputs can be made quickly and easily. The large touch screen has plenty of room to display the reference, target and devices under test temperatures. At the end of a calibration process, the PTC provides the complete calibration certificate. • Some of the best measurement uncertainties on the market • Patented control technology - Fastest stabilisation times on the market - Time savings of up to 50 % • -55 to 200°C (-67 to 392°F) is the widest temperature range with cooling and heating on the market (PTC200) • RT to 700°C (RT to 1292°F) is the highest temperature range in the series (PTC700) • World's fastest dry-block temperature calibrator • Unique hybrid technology: combination of highperformance resistance heating with Peltier elements specially optimized for the cooling process for fastest cooling and heat-up times • Patented touch screen function for simple and convenient operation • Device under test management with optional barcode scanner P/N IOPTC-BAR-1 • Automatic calibration with optional camera P/N IOPTC-CAM-2 and
カタログの1ページ目を開く
Druck temperature calibrators User Interface Every Druck temperature calibrator is meticulously tested for accuracy and stability. This is certified by our traceable factory calibration certificate, which we issue with every temperature calibrator, or an optional Dakks (ISO17025) accredited calibration certificate can be purchased. This is to guarantee that you receive a perfect product which can be traced back to national and international temperature measurement standards. • Clear display All important information at a glance Druck temperature calibrators are used for the verification of...
カタログの2ページ目を開く
• Temperature regulator with model-based state control • Special regulation algorithm based on knowledge and experience from space travel • Unique temperature stability of < 0.001 °C / K • Anticipatory activation of the heating and cooling elements The settling time to the target temperature is reduced by approx. 90% at each calibration point Time savings of up to 50% with each calibration process Unique hybrid technology • The best of two worlds: with our unique hybrid technolofy, we combine the benefits of a powerful resistance heating with special Peltier elements that have been...
カタログの3ページ目を開く
Technical data PTC200 Functions Temperature range -55 to 200 °C at ambient temperature 20 °C -31 to 329 °F at ambient temperature 68 °F Dimension for the calibration insert Ø 28 x 150 mm (calibration insert easily exchangeable) External reference temperature sensor Internal reference temperature sensor Display accuracy Temperature stability Temperature distribution Axial Radial Stabilization time (with external reference temperature sensor) to ±0.05 °C to ±0.09 °F to ±0.005 °C to ±0.009 °F Resolution of the temperature display 0.1 / 0.01 / 0.001 °C (selectable) Temperature units...
カタログの4ページ目を開く
Temperature steps PTC200 with external reference temperature sensor (P/N IOPTC-EXSEN-1) Step test with commercially established limit temperatures and 15 minutes additional holding time after stabilization 225 200 Nominal temperature Calibrator PTC200 Nominal temperature Calibrator PTC200 Temp display Temp–display nominal – nominal temp ΔT temp / K ΔT / K Device under test Ø 6 mm Calibrator PTC200 Calibrator PTC200 Time t (hh:mm) 1:15
カタログの5ページ目を開く
Technical data The PTC700 can be operated up to 700 °C (1292 °F). For physical reasons, it achieves the best accuracy at temperatures up to 660 °C (1220 °F). For temperatures between 660 °C (1220 °F) and 700 °C (1292 °F) we recommend the use of a separate reference thermometer. PTC700 Functions Temperature range Dimension for the calibration insert Ø 29 x 150 mm (calibration insert easily exchangeable) Dry block air shield insert (Function 1) External reference temperature sensor All values determined at 660 °C (1220 °F) Display accuracy Temperature stability Temperature distribution ...
カタログの6ページ目を開く
The PTC200 are supplied with a safety manual and traceable factory calibration certificate as standard along with the following kit: Kit included with PTC200 DRUCK P/N External reference sensor -55 to 255 °C straight version World plug and lead set Insert exchange tongs Ethernet Cable 1. Select the model 2. Select PTC and External reference sensor (ext ref sensor) calibrations Model Type (Mandatory to select one) PTC200 Premium Temperature Calibrator (Dry Block) -55 to 200°C (-67 to 392°F) PTC and ext ref sensor calibration certificate – select only one 0 Traceable factory calibration on...
カタログの7ページ目を開く
The PTC700 are supplied with a safety manual and traceable factory calibration certificate as standard along with the following kit: Kit included with PTC700 DRUCK P/N External reference sensor 5 to 700 °C straight World plug and lead set Insert exchange tongs Ethernet Cable 1. Select the model 2. Select PTC and External reference sensor (ext ref sensor) calibrations Model Type (Mandatory to select one) PTC700 Premium Temperature Calibrator (Dry Block) RT to 700°C (RT to 1292°F) PTC and ext ref sensor calibration certificate – select only one 0 Traceable factory calibration on PTC 1 Dakks...
カタログの8ページ目を開くDruckのすべてのカタログと技術パンフレット
-
PACE Tallis
7 ページ
-
DPI610E-Aero
3 ページ
-
PACE 6000-ADC
3 ページ
-
Accuracy under pressure
11 ページ
-
DPI 705E
10 ページ
-
Druck DPI620G Datasheet
19 ページ
-
DPS5000 I2C
5 ページ
-
DPI610E Datasheet
17 ページ
-
DPS5000 CANBus
6 ページ
-
ADTS 405 Mkll
10 ページ
-
ADTS542F
6 ページ