

カタログの抜粋

ADB=Airfield Solutions EHP-L LED Elevated Heliport Perimeter Light I Compliance with Standards FAA: Designed according to AC 150/5390-2 Heliport Design. L-861T AC 150/5345-46 (Current Edition) and the FAA Engineering Brief No. 67. ETL Certified (L-861T). Uses EHP is intended for use as a heliport perimeter light. The green and yellow omnidirectional light is used to define the perimeter of the area the helicopter requires for touchdown and lift-off (TLOF). • Yellow EHPs are typically used on military applications • Green EHPs are typically used for new civil applications • Blue EHPs can be used for lead-in taxiway applications Features • Overall height installed is less than 8 inches, complying with AC 150/5390-2C requirements for raised perimeter lights • Average individual LED life of 50,000 hours (minimum) • 95-264 VAC, 50/60 Hz power supply minimizes installation costs by reducing required cable run wire size. Light output stays constant regardless of input voltage range. • EHP with arctic option (U.S. Patent 7192155 B2) uses a thermostatically controlled heater to prevent ice and snow buildup from obscuring light output. Melts ice similar to traditional incandescent fixtures. • Thermostatically controlled heater cycles on and off when temperature drops below freezing, reducing overall energy consumption • For voltage-driven applications, the EHP with a thermostatically controlled arctic option is 2.6 times more efficient in warm weather operations and 1.5 times more efficient than a typical 54 W(VA) fixture in cold weather operations • More than 500,000 ADB elevated LED fixtures are in use around the USA • Direct replacement for incandescent fixtures • Fixture uses aluminum casting, stainless steel hardware, and is protected with aviation yellow powder coat finish • All parts are corrosion-resistant • Rugged, low-profile design reduces the potential for damage in the FATO perimeter • For additional features common to all of ADB’s elevated LED fixtures, see data sheet 3043. LED Color G = Green1 Y = Yellow1 B = Blue i Power 1 = Voltage Driven, 95-264 VAC, 50/60 Hz1 2 = 50/60 Hz, Current Driven, 2.8-6.6 A Overall Height 1 = 8 inches with junction box, no coupling1 2 = 16 inches with junction box, 1.5-inch coupling1 3 = 24 inches with junction box, 1.5-inch coupling1 4 = 8 inches w/out j-box, with 1.5-inch coupling 5 = 8 inches w/out j-box, with 2-inch coupling 6 = 16 inches w/out j-box, with 1.5-inch coupling 7 = 24 inches w/out j-box, with 1.5-inch coupling 8 = 16 inches w/out j-box, with 2-inch coupling 9 = 24 inches w/out j-box, with 2-inch coupling A = 12 inch OAH w/out j-box, with 1.5-inch coupling B = 12 inch OAH w/out j-box, with 2-inch coupling Arctic Option 0 = Without arctic option 1 = With arctic option2 Notes 1 Not ETL Certified 2 When powered by a parallel circuit, heater is designed for use at only 120 VAC, ±10%, 50/60 Hz. Electrical Supply Operating Conditions Temperature: -40 °F to +131 °F (-40 °C to +55 °C) Humidity: 0 to 100% Wind: Withstands wind velocities up to 300 mph (480 kph)
カタログの1ページ目を開く
1 Fixture load does not include isolation transformer load ADB Airfield Solutions Leuvensesteenweg 585 B-1930 Zaventem Belgium ADB Airfield Solutions, LLC 977 Gahanna Parkway Columbus, OH 43230 USA © ADB Airfield Solutions All rights reserved Product specifications may be subject to change, and specifications listed here are not binding. Confirm current specifications at time of order.
カタログの2ページ目を開くADB SAFEGATEのすべてのカタログと技術パンフレット
-
RELIANCE
6 ページ
-
L-88 series
4 ページ
-
AXON
3 ページ
-
Ace3
3 ページ
-
Aglas
6 ページ
-
Optamos
4 ページ
-
One control
4 ページ
-
Infomax
4 ページ
-
Diflis
4 ページ
-
Declos
4 ページ
-
Acemax
4 ページ
-
FAP
3 ページ
-
ALSF-SSALR
6 ページ
-
SYS 800D-S
6 ページ
-
SL-AC-AS-I
2 ページ
-
DTH-LP RWSL THL-RIL
2 ページ
-
DTS-LP/DTC-LP
4 ページ
-
DRE-LP RWSL REL
2 ページ
-
BPE
4 ページ
-
LEAP
4 ページ