GMS800 FIDOR® TOTAL HYDROCARBON ANALYZER TRANSIC100LP LASER OXYGEN TRANSMITTER The good nose for oxygen Continuous monitoring of hydrocarbon emissions Gas transmitter
Aprire il catalogo a pagina 1
TRANSIC100LP: Laser oxygen transmitter Simple, fast and low maintenance Process parameters are best measured where they are relevant and present in an unaltered state – directly in the process. "In-situ measuring technology" or "Inline measuring" are the phrases used. The process parameters are determined under process conditions. The TRANSIC100LP is an oxygen transmitter that measures in-situ or "inline". The sensor is designed as a measuring probe. This ensures that the lens system in the transmitter is always optimally aligned and installation is very simple. The measuring task can be...
Aprire il catalogo a pagina 2
The TDLS Tunable Diode Laser Spectroscopy is primarily used in high-end gas analyzers and is characterized by its highly selective measurement capability. The oxygen properties are used for O2 measurement: That means O2 atoms in the near infrared range are stimulated at specific wavelengths. A laser diode modulates the radiation precisely over an absorption peak. The high-energy radiation transfers energy to the O2 atoms and the signals becomes weaker. In the measuring probe, the laser beam hits the O2 atoms and is weakened according to the concentrations of oxygen present there. A receiver...
Aprire il catalogo a pagina 3
TRANSIC121LP and TRANSIC151LP: Measuring oxygen in potentially explosive atmospheres An explosion can only occur when all three elements (fuel, an ignition source and oxidant), referred to as the explosion triangle, are present. The primary explosion protection prevents the simultaneous occurrence of a fuel and an oxidant. If flammable substances cannot be avoided, no oxidants may be present. Commission, 1994) for devices and 1999/92/EC (European Commission, 1999) for operation (ATEX Directive) and the harmonized standards, or NEC 500 and NEC 505 in the USA. For use in potentially explosive...
Aprire il catalogo a pagina 4
Dust: II 2 D Ex ibtb IIICTS5°C Db Dust: II 2 D Ex ibtb INCT85°C Db Subject to change without notice
Aprire il catalogo a pagina 5
THE GOOD NOSE FOR OXYGEN Additional information Product description Measuring the oxygen in the process can be quite simple. The TRANSICIOOLP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure 02 reliably. A tech- nology more common in the world of • 02 transmitter based on high-perfor- mance laser spectroscopy (TDLS) atmospheres (FM, ATEX and lECEx • Measurement directly in-situ or extractive using a sample gas cell Your benefits • Measures in real-time directly in the • Easy installation and operation • Self-diagnostics with maintenance...
Aprire il catalogo a pagina 6
Fields of application • Monitoring of inert gas blanketing in tanks and vessels • O2 measurement in process gases • Measurements in potentially explosive atmospheres • Process monitoring in fermenters and bioreactors • Room air monitoring • Quality monitoring for the production of technical gases • Replacement of extractive paramagnetic oxygen analyzers and electrochemical cells Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the...
Aprire il catalogo a pagina 7
Electrical connection Voltage 24 V DC TRANSIC151LP: 21.6 ... 26.4 V For ATEX/IECEx version via TSA151 power supply, a PELV power supply is mandatory Current consumption Power consumption Corrective functions Test functions Adjustment with ambient air or test gases Contamination check
Aprire il catalogo a pagina 8
Ordering information Our regional sales organization will help you to select the optimum device configuration. Type code TRANSIC111LP Version A With flange for in-situ installation, <0.5 bar, O2 measuring range of 0 ... 25 vol.-% B With wall bracket for ambient air measurement, O2 measuring range 2 ... 25 vol.-% C With sample cell and wall bracket, PN10, O2 measuring range 0 ... 25 vol.-% D With flange for in-situ installation, <0.5 bar, O2 measuring range 0 ... 100 vol.-% [1] E With sample cell and wall bracket, PN10, O2 measuring range 0 ... 100 vol.-% [1] F With flange for in-situ...
Aprire il catalogo a pagina 9
[1] With certificate for oxygen service [2] For use in clean gas only or with a sample cell [3] Not selectable for the O2 measuring range 0 ... 100 vol.-%. Not recommended for wet gas near dew point. [4] Can be reconfigurated in the field [5] Factory setting: 0 … 25 vol-% O2 [6] Can be reconfigurated in the field (requires a serial interface and a terminal program on PC) [7] Selectable only for the output range of 4 ... 20 mA [8] Factory setting: 10 vol-% O2 [9] PTFE filter for reference gas inlet recommended TRANSIC121LP Version A With flange for in-situ installation, < 0.5 bar, O2...
Aprire il catalogo a pagina 10
TRANSIC151LP Version A With flange for in-situ installation, < 0.5 bar, O2 measuring range of 0 ... 25 vol.-% B With wall bracket for ambient air measurement, O2 measuring range 2 ... 25 vol.-% C With sample cell and wall bracket, PN10, O2 measuring range 0 ... 25 vol.-% F With flange for in-situ installation, PN10, O2 measuring range of 0 ... 25 vol.-% G With weld-on nozzle for in-situ installation, PN10, O2 measuring range 0 ... 25 vol.-% H With 3’’ clamp connection for in-situ installation, PN10, O2 measuring range 0 ... 25 vol.-% Filter type 1 No filter [1] 2 Stainless steel mesh 3 PTFE...
Aprire il catalogo a pagina 11
TRANSIC100LP Gas transmitters only in a non-hazardous area! [6] Selectable only for the output range of 4 ... 20 mA [7] Factory setting: 10 vol-% O2 [8] For connection between transmitter and power supply TSA151 only SICK Ex i cabel have be used [9] PTFE filter for reference gas inlet recommended [10] Connection to PC should be done only in a non-hazardous area! Use SICK service interface cables only. [11] Do not operate TRANSIC151LP transmitter without TSA151 power supply! Dimensional drawings (Dimensions in mm (inch)) TRANSIC100LP with flange adapter for process measurements below 0.5 bar...
Aprire il catalogo a pagina 12Tutti i cataloghi e le schede tecniche SICK SENSOR INTELLIGENCE
-
Safety Switches
20 Pagine
-
Magnetic Cylinder Sensors
176 Pagine
-
Opto-Electronic Protective Devices
32 Pagine
-
REGISTRATION SENSORS
24 Pagine
-
CLV63x, CLV64x, CLV65x
102 Pagine
-
WTB16 Bluetooth®
135 Pagine
-
WE9LC-3_A71
3 Pagine
-
Automation light grids
8 Pagine
-
Encoders and Inclination Sensors
32 Pagine
-
Proximity Sensors
324 Pagine
-
Dust measuring devices
172 Pagine
-
Detection and Ranging Solutions
124 Pagine
-
Distance Sensors
404 Pagine
-
Vision
124 Pagine
-
Top-Products from SICK
556 Pagine
-
Fluid Sensors
243 Pagine
-
Registration Sensors
276 Pagine
-
IDENTIFICATION SOLUTIONS
24 Pagine
-
FLOWSIC300 Ultrasonic Gas Flow Meter
177 Pagine
-
FLOWSIC300 Gas flow meters
12 Pagine
-
FLOWSIC500 Gas flow meters
16 Pagine
-
FLOWSIC600 Ultrasonic Gas Flow Meter
138 Pagine
-
FLOWSIC600 Gas Flow Meter
16 Pagine
-
ConVer
12 Pagine
-
GM32 In-situ gas analyzers
28 Pagine
-
GM901 Carbon Monoxide Gas Analyzers
12 Pagine
-
GM35 In-Situ IR Gas Analyzer
16 Pagine
-
WT100-2 with background suppression
46 Pagine
-
Encoders
788 Pagine
-
Opto Electronic Protective Devices
712 Pagine
-
GMS800 Extractive Gas Analyzers
20 Pagine
-
MERCEM300Z Mercury Monitoring System
12 Pagine
-
WT100-2 energetic
47 Pagine
-
VPS Pro Profiling systems
20 Pagine
-
Photoelectric Sensors
949 Pagine
-
G6 - Global Sensor
20 Pagine
-
Hand-Held Scanners IDMx
48 Pagine