

Estratti del catalogo

CUSTODY TRANSFER GAS FLOW MEASUREMENT AND PROCESS MONITORING
Aprire il catalogo a pagina 1
INVESTING IN A HIGH-QUALITY METER SAVES MONEY Every day natural gas flows in great quantities through pipelines or into storage facilities, thus changing owners. Precise gas quantity measurement is of the utmost importance, as even very small measurement errors could result in substantial economic loss. In addition, challenging ambient measurement conditions often play a decisive role. Moisture, ice, cold, heat and desert sand place great demands on the instruments in the field. This is why a gas flow meter is needed that is both accurate and reliable. The FLOWSIC600 gas flow meter from...
Aprire il catalogo a pagina 2
Highly Durable High Measurement Accuracy Maximum Reliability Excellent System Integration Worldwide Approvals The FLOWSIC600 compact gas flow meter hermetically shields all of its measurement equipment from the environment. The use of internal cable routing prevents harsh climate conditions and contamination from harming the device. The FLOWSIC600 is virtually maintenance-free. The FLOWSIC600 is available for nominal pipe sizes from DN80 to DN1200 for custody transfer applications, and as small as DN50 for process applications. Easy connection to flow computers allows straightforward...
Aprire il catalogo a pagina 3
EXCELLENT MEASUREMENT TECHNOLOGY IN AN OUTSTANDING MEASUREMENT DEVICE The FLOWSIC600 is a top-quality measurement device. It features a robust meter body incorporating measurement equipment, performs measurement with high noise immunity and long-term stability, and is nearly maintenance-free. Ultrasonic Sensors from SICK The FLOWSIC600 is equipped with high-performance ultrasonic sensors developed by SICK. A hermetically sealed titanium housing contains ultrasonic transducers that operate at a selectable ultrasonic frequency of 80 kHz, 135 kHz, 200 kHz, or 300 kHz to match the operating...
Aprire il catalogo a pagina 4
Automatic Self-Diagnostics The FLOWSIC600 is equipped with a warning signal that informs the user of a malfunction before the measured value is affected. To do this, current diagnostic indicators are compared to indicators that were learned by the device under normal measurement conditions. The results of the self-diagnostics are permanently logged by an internal electronic data log to allow a retroactive check of the measurement process. Important measured variables such as gas flow and gas velocity (VOG) or diagnostic parameters such as signal-to-noise ratio (SNR) or speed can be read...
Aprire il catalogo a pagina 5
GAS FLOW METERS FOR CUSTODY TRANSFER TRAFFIC AND PROCESS APPLICATIONS Additional information Product description is an ultrasonic gas flow meter and sets the standard in its market segment. The visually technical design demonstrates that it is geared to the tough industry conditions. The compact design with integrated cable routing means that the measuring system is durable, failsafe, • High efficient ultrasonic transducers • Direct path layout (Westinghouse • Intelligent self-diagnostics • Compact, robust design Your benefits • Long-term stability, reliable measure- extensive diagnostics...
Aprire il catalogo a pagina 6
Fields of application • Custody transfer applications (natural gas, N2, O2, air, ethylene) • Onshore and offshore applications • Underground gas storage facilities (bidirectional measur- • Cryogenic gas applications down to –194 °C • Also for process gases • For gases with high H2S component such as sour gas or biogas ment possible) Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. System Measured...
Aprire il catalogo a pagina 7
AGA-Report No. 9 API 21.1 OIML D11 OIML R137-1 ISO 17089-1 BS 7965 Pattern approval: MID, PTB, NMi, Measurement Canada, GOST ... Ex-approvals IECEx Gb/Ga Ex d e ib [ia Ga] IIA T4 Gb/Ga Ex d e ib [ia Ga] IIC T4 Ultrasonic transducers intrinsically safe II 1/2G Ex de ib [ia] IIA T4 II 1/2G Ex de ib [ia] IIC T4 Ultrasonic transducers intrinsically safe NEC/CEC (US/CA) Class I, Division 1, Groups B, C, D T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Division 1, Group D T4 Class I, Division 2, Group D T4 Ultrasonic transducers intrinsically safe Electrical safety Enclosure rating Analog...
Aprire il catalogo a pagina 8
Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings (Dimensions in mm (inch)) Versions with nominal sizes from 3" up to and including 14" (cast) Subject to change without notice FL0WSIC600 GAS FLOW METERS | SICK
Aprire il catalogo a pagina 9
Versions for nominal sizes from 16" (forged) Longitudinal section for nominal widths up to 48" Nominal pipe size 3" Connection flange Width of measuring section Internal diame(D) ter (E)
Aprire il catalogo a pagina 10
Subject to change without notice FL0WSIC600 GAS FLOW METERS | SICK
Aprire il catalogo a pagina 11
Nominal pipe size Connection flange Width of measuring section Internal diame(D) ter (E) Data on request ASME B16.47 Data on request ASME B16.47 Data on request ASME B16.47 8009840/2014-09 Subject to change without not
Aprire il catalogo a pagina 12
Nominal pipe size Connection flange Width of measuring section Internal diame(D) ter (E) Data on request ASME B16.47 Data on request ASME B16.47 8009840/2014-09 Subject to change without notice
Aprire il catalogo a pagina 13
FLOWSIC600 Gas flow meters Instruction for installation FLOWSIC600 integration into the pipeline for unidirectional use in configuration 1 (A) and configuration 2 (B) ≥ 3 DN ≥ 10 DN 1 FLOWSIC600 2 Temperature measuring point 3 Flow conditioner FLOWSIC600 integration into the pipeline for bidirectional use in configuration 1 (A) and configuration 2 (B) ≥ 10 DN 1 FLOWSIC600 2 Temperature measuring point 3 Flow conditioner
Aprire il catalogo a pagina 14
WWW.MYSICK.COM – SEARCH ONLINE AND ORDER Search online quickly and safely – with the SICK “Finders” Efficiency – with the e-commerce tools from SICK Product Applications Literature Service Accessories Software Product Finder: We can help you to quickly target the product that best matches your application. Applications Finder: Select the application description on the basis of the challenge posed, industrial sector, or product group. Literature Finder: Go directly to the operating instructions, technical information, and other literature on all aspects of products from SICK. Find out prices...
Aprire il catalogo a pagina 15Tutti i cataloghi e le schede tecniche SICK SENSOR INTELLIGENCE
-
Safety Switches
20 Pagine
-
Magnetic Cylinder Sensors
176 Pagine
-
Opto-Electronic Protective Devices
32 Pagine
-
REGISTRATION SENSORS
24 Pagine
-
CLV63x, CLV64x, CLV65x
102 Pagine
-
WTB16 Bluetooth®
135 Pagine
-
WE9LC-3_A71
3 Pagine
-
Automation light grids
8 Pagine
-
Encoders and Inclination Sensors
32 Pagine
-
Proximity Sensors
324 Pagine
-
Dust measuring devices
172 Pagine
-
Detection and Ranging Solutions
124 Pagine
-
Distance Sensors
404 Pagine
-
Vision
124 Pagine
-
Top-Products from SICK
556 Pagine
-
Fluid Sensors
243 Pagine
-
Registration Sensors
276 Pagine
-
IDENTIFICATION SOLUTIONS
24 Pagine
-
FLOWSIC300 Ultrasonic Gas Flow Meter
177 Pagine
-
FLOWSIC300 Gas flow meters
12 Pagine
-
FLOWSIC500 Gas flow meters
16 Pagine
-
FLOWSIC600 Ultrasonic Gas Flow Meter
138 Pagine
-
ConVer
12 Pagine
-
GM32 In-situ gas analyzers
28 Pagine
-
GM901 Carbon Monoxide Gas Analyzers
12 Pagine
-
GM35 In-Situ IR Gas Analyzer
16 Pagine
-
WT100-2 with background suppression
46 Pagine
-
Encoders
788 Pagine
-
Opto Electronic Protective Devices
712 Pagine
-
GMS800 Extractive Gas Analyzers
20 Pagine
-
MERCEM300Z Mercury Monitoring System
12 Pagine
-
WT100-2 energetic
47 Pagine
-
VPS Pro Profiling systems
20 Pagine
-
Photoelectric Sensors
949 Pagine
-
G6 - Global Sensor
20 Pagine
-
Hand-Held Scanners IDMx
48 Pagine