Estratti del catalogo

EDM Cloud Remote Monitoring Solutions © Crystal Instruments, January 2014
Aprire il catalogo a pagina 1
Architecture 1: EDM Cloud runs on the Internet Spiders at multiple locations Client Browser EDM Data Server Ethernet or Wireless Advantages: Client Browser Measurement locations can be far away from the users Access the data in real time from anywher
Aprire il catalogo a pagina 2
Architecture 2: EDM Cloud runs on a Local Area Network (LAN) Spiders at multiple locations Client Browser Ethernet or Wireless EDM Data Server Ethernet or Wireless Client Browser Advantages: High speed data access and data transfer. Limitation: LAN might be limited by the physical installatio
Aprire il catalogo a pagina 3
What Can be Measured with a Spider System Vibrations with alarm limits Time blocks Long recording signals RMS or peak levels Harmonics level Power spectra FRF (Frequency response function) Phase measurement Various sound levels with alarm limits Temperature, humidity, vol
Aprire il catalogo a pagina 5
□ Access the instruments and data center with history data online □ Hardware can be offline or online □ Web based client application (no software installation) □ Share online information with your stakeholders via Internet
Aprire il catalogo a pagina 6
Unique Hardware Solution Spider-80X has extremely compact packaging Size approximately letter size Full Ethernet connection 150dBFS dynamic range: input range selection not needed Onboard flash memory storage Spider-DAQ: Measure strain, high voltage, temperature, humidity Input channels
Aprire il catalogo a pagina 7
Front View: 8 input channels with control buttons Back View: Power, Ethernet connector, GND, RS-485, reset button
Aprire il catalogo a pagina 8
A 64 channel System consists of Eight Spider-80X
Aprire il catalogo a pagina 9
□ The Spider-DAQ is a module that can either connect to a PC using an Ethernet connection or run without a PC. Using various 8B modules, the Spider-DAQ can measure voltage, strain, current, frequency, temperature, and many more physical quantities.
Aprire il catalogo a pagina 10
Dynamic Range is Critical In machine condition monitoring, one of the biggest challenges is how to measure both large and small signals without changing the input settings
Aprire il catalogo a pagina 11
02) United States Patent Zhuge(io) Patent No.: US 7.302,354 B2(45) Date of Patent: Nov. 27, 2007 (54) CROSS-PATH CALIBRATION FOR DATA ACQUISITION USING MULTIPLE DIGITIZING PATHS (75) Inventor: .1 arnes Zhuge. Palo Alio, CA (US) (73) Assignee: Crystal Instruments Corporation, Sunnyvale, CA (US) 1 OTHER PUBLICATIONS Anderson, Ole Thorhauge el al., “New Technology Increases tine IJynnmic Ranges of Data Acquisition Systems Jliistd on 24-bit Technology," Sound out Vibration, Apr. 20(15. pp. 8-11. * cited by examiner Primary Examiner John Barlow Assistant Examiner l lien Vo (74) Attorney,...
Aprire il catalogo a pagina 12
□ Super-Admin: Has the rights to install, upgrade and configure the server software. Also has the rights of Admin and Users. □ Admin: Has the rights to configure the Project, Measurement List, Location of Spiders, Signal List and Runlog. Also has the rights of Users □ User: Only has the rights to view or download the measurement data, runlog, events. Does not have rights to change the settings
Aprire il catalogo a pagina 13
Log in anywhere with a Browser Supports PC, iPod, Android Phone etc.
Aprire il catalogo a pagina 14
Refresh Time 1230 2013 14:47:59 Bey view Daly City Schufrt PatkJ* jay Whale Cove Stale Beach San Mateo \ South Sarv, Redwood Crty Portoia Valley ▼ Milpitas ^ \ i- Roc* ^ 4 ^ • Sunnyvale • Alum Rock Joseph 0 Grant San Jose Mpwwlow,,,! /r^ \ HUnoirf South, Evergreen I San Joae S Henry W Coe ^V. Slate Path Mor, MapAau S2C13Goofl'* "armsofusa Rapona map eno' Location of Spider device can be set by their longitude and latitude and then displayed on the Google Map.
Aprire il catalogo a pagina 15
Automated Schedule and Limiting Test Automated limit test function allows the Spider-80X to conduct automated limit checking for time or frequency signals. Test Signals: time block signals, auto spectrum, frequency response function, octave spectrum. Limit Signals: user defined upper or low limit signals. For spectra signal the spectrum type will also be assigned. Limit signals will be bound to testing signals. Maximum segments of each limit signal: 64; Maximum number of limit signals: 64. Testing Schedule: automatically control the test duration and automates the operation. Multiple...
Aprire il catalogo a pagina 16
□ Acquire time and frequency data continuously up to 102.4 kHz for all channels □ Record up to 4 GB data into internal flash memory □ Large buffers increase reliability □ Reserve power supply recovers data in the event of power loss
Aprire il catalogo a pagina 17
How Customized Event Strings work? Step 1 EDM sets the alarm limit together with a special message string, such as “Exceeding Limit” User will receive an alarm email Step 3 EDM Cloud Email Service When alarm event happens, the customized string, “Exceeding Limit”will be sent to the EDM Cloud email service
Aprire il catalogo a pagina 18
Step by Step Configuration
Aprire il catalogo a pagina 20
Hardware Configuration: Wired Connection • The Spider devices are connected to the Ethernet routers • Routers communicate to the server located on LAN or the Interne
Aprire il catalogo a pagina 21
•The Spider devices are connected to the wireless modems •Wireless modem communicates to the Internet •Data plan for all major carrier providers are available
Aprire il catalogo a pagina 22
Measured signals may include: □ Time recording signals □ Octave spectra □ Sound level measurement □ Auto-power spectra □ RMS, Peak measurement □ Time blocks • - Time Straw* | hi PT)^tJ jhsCh2[t] ‘hlCM[tj • - Oct.Tw hi 'nmeTraoe(CMxn hi TlmeTrsce(Ch2Xn TimeTraoe(ChJXn is TimeTra<a(CMXG Is. OCT(Chl) kocncw; koodoo) kOCT(CM) • - Sound Level Meter SLKDnveT race(Ch 1 Xt] SLMTimeTr«ce(Oi2Xt! is SLHTlmeTrace(Ch3 )(t j SLMTimeTrsaKCMXti k SI MValuetfChl) kd»«togram(Oil) k SLM valued 2) l kd»lstogtam(CTi2) Ik SLMValues<0i3) k d»*5togram((Ji3) k SLMValues(Ch4) 1 k dWstograin(ch4) • - TlmeBbdo hi...
Aprire il catalogo a pagina 23
Set up the alarm limits for measurement signals □ High alarm or low alarm □ With break points □ Check the value over the range with percentage
Aprire il catalogo a pagina 24
Project, Location, and Signal Setup
Aprire il catalogo a pagina 25
Users can receive emails that contain the keywords that are preset by the users, for example, “limits exceeded”.
Aprire il catalogo a pagina 26Tutti i cataloghi e le schede tecniche Crystal Instruments Corporation
-
Crystal Instruments
55 Pagine
-
EDM MODAL
12 Pagine
-
SPIDER-100
20 Pagine
-
SPIDER-81
8 Pagine
-
SPIDER-80X
8 Pagine
-
SPIDER-80SG
8 Pagine
-
COCO-80X
20 Pagine
-
Spider-80X + Spider-80Xi
32 Pagine
-
VIBRATION CONTROL SYSTEMS
26 Pagine