FIAMC S.p.A. Presentation
1 / 58Pages

{{requestButtons}}

Extraits du catalogue

FIAMC S.p.A. Presentation - 2

Main products HYDRAULIC EQUIPMENT ENVIRONMENTAL CONTROL SYSTEMS →ECS for aircraft cabin

Ouvrir le catalogue en page 2
FIAMC S.p.A. Presentation - 3

Main programs Wing Tip Pod Cooling System Krueger Flap Actuator Airbrake Actuator Flight Refueling Probe Selector valve Auxiliary Doors Dampers Rudder Bias Actuator Hydraulic Pressure Switches Hydraulic Pressure Switches Main Entry Door Actuation System (G280)

Ouvrir le catalogue en page 3
FIAMC S.p.A. Presentation - 4

Main programs JAS-39 Gripen Environmental Control Unit for reconnaissance pod Helicopter AW101 Landing Gear Control Lever and Valve Environmental Control Unit for reconnaissance pod Hydraulic Valves

Ouvrir le catalogue en page 4
FIAMC S.p.A. Presentation - 5

Landing Gear Control Lever (MB339 only) Environmental Control Unit for the aircraft cabin AMX Air Flow Control Regulator Canopy Seal Regulator Valve Solenoid Operated Valve Pressure Switches Fuel Booster Pump Spey Engine Components

Ouvrir le catalogue en page 5
FIAMC S.p.A. Presentation - 7

Engineering Design & Development Capabilities Cooling systems based on vapor cycle and multivortex® compressors Air conditioning system based on standard automotive components Hydraulic equipment Fuel system equipment Ram air turbines Aerodynamics Electronic hardware and software

Ouvrir le catalogue en page 7
FIAMC S.p.A. Presentation - 8

Ram Air Turbines Hydraulic pressure switches Tornado Hydraulic equipment AMX Hydraulic & pneumatic equipment Hydraulic equipment for EH101 helicopter Hydraulic equipment Cold plate

Ouvrir le catalogue en page 8
FIAMC S.p.A. Presentation - 9

Our facilities Two Plants: → Senago, Milan → Pero, Milan Test & Validation Resources Continuous flow wind tunnel (Mach 0.5, 600 mm dia. test section – Pero Plant) Rigs for hydraulic tests working with MIL-H and Skydrol fluids Rigs for aerodynamic tests (high speed flows up to Mach 0.9 – Senago Plant) Leakage inspection by He spectrometric detection Non-Destructive Test (Magnetic Particle Inspection and Liquid Penetrant Inspection) Design Resources AutoCad Inventor modeling and drafting Catia V.5 CAD Ansys CFD analysis Ansys structural analysis Simulink (Matlab based simulation and anal

Ouvrir le catalogue en page 9
FIAMC S.p.A. Presentation - 10

Our organization Small business company Manpower: 90 employees Chief Executive Officer R. Callerio Information Technology D. Dolini Personnel & Finance M. Colella Human Resources L. Attardo Administration / Accounting M. Molgora Sales & Product Support P. Marelli Health & Safety / Environment D. Carm inucci Quality M anager M. Restelli M echanical Engineering P. Cuppari Quality Control A. Sgam mato

Ouvrir le catalogue en page 10
FIAMC S.p.A. Presentation - 11

Part 145 (In progress, due end 2021 / beginning 2022) CND - Penetrant Liquids, Magnetic Particles

Ouvrir le catalogue en page 11
FIAMC S.p.A. Presentation - 12

Equipment & Systems

Ouvrir le catalogue en page 12
FIAMC S.p.A. Presentation - 13

Hydraulic/Pneumatic equipment and systems Cooling and conditioning systems

Ouvrir le catalogue en page 13
FIAMC S.p.A. Presentation - 14

Hydraulic/Pneumatic equipment and systems Design according Customer’s specification, supported by CAD (Autodesk Inventor® and Catia ®) and CAE (Ansys CFD and Structural Analyses) of Actuators Valves Pumps Pressure regulators to be used on various types of aircraft (fighters, transport, business jet, helicopters). Prime Contractor for the EF2000, Gulfstream G150/G200/G280, AW101 and other programmes. Latest applications: Passengers Main Door actuation system for Gulfstream G280 Aircraft (Customer: IAI/Gulfstream) Hydraulic Actuator for secondary flight controls (Customer: IAI) Pneumatic...

Ouvrir le catalogue en page 14
FIAMC S.p.A. Presentation - 15

Weight reduction policy FEM simulation reduced weight by 20% from first design

Ouvrir le catalogue en page 15
FIAMC S.p.A. Presentation - 16

Main features: Shut-Off Valve Solenoid Operated Operating Fluid: Fluid Temperature: Operating Pressure:

Ouvrir le catalogue en page 16
FIAMC S.p.A. Presentation - 17

Shut-Off Valve Body Stress/Strain Analysis Fatigue Analysis

Ouvrir le catalogue en page 17
FIAMC S.p.A. Presentation - 18

Hydraulic Actuator This Hydraulic Actuator is an unbalanced, double effect linear hydraulic actuator featuring: Mechanical locking device to hold the retracted position Proximity switch and relevant electrical connector

Ouvrir le catalogue en page 18
FIAMC S.p.A. Presentation - 19

Hydraulic Actuator Operating Fluid Operating Temperature Operating Pressure Fluid Temperature Piston Load (retraction) 10400 N Piston Load (extension) Piston Speed Closing Piston Speed Closing

Ouvrir le catalogue en page 19
FIAMC S.p.A. Presentation - 20

Passengers Main Entry Door Actuation system for Gulfstream G280 Aircraft Door closed Door open FIMAC is responsible for the component design and functional integration of the system

Ouvrir le catalogue en page 20
FIAMC S.p.A. Presentation - 21

Passengers Main Entry Door Actuation System for Gulfstream G280 Operating Temperature Operating Fluid Operating Pressure Assy Weight Piston Load (Extension) Piston Speed Operating Voltage (Valve) 28 Vdc Linear Actuator with Stroke Snubbing Gulfstream G280 MED Actuator Cross Section

Ouvrir le catalogue en page 21
FIAMC S.p.A. Presentation - 22

Passengers Main Entry Door Actuation System for Gulfstream G280 Gulfstream G280 MED Selector Valve The MED-SOV is a spring loaded, solenoid operated, three-way, two-position directional selection valve provided with electrical indication of the energized condition.

Ouvrir le catalogue en page 22
FIAMC S.p.A. Presentation - 23

Krueger Flap Actuator for Panavia Tornado Operating Temperature Operating Fluid Operating Pressure Piston Load (retraction) 27000 N Piston Load (exstention) 6800 N Piston Speed Operating Voltage

Ouvrir le catalogue en page 23
FIAMC S.p.A. Presentation - 24

Spoiler/Air Brake Actuator – Gulfstream-IAI G150/G200 Operating Fluid Operating Temperature Operating Pressure Retracting Load Extending Load Locking System in retracting position Galaxy 200 Eight actuators are installed on each aircraft (four for each wing

Ouvrir le catalogue en page 24
FIAMC S.p.A. Presentation - 25

In-flight Refuelling Solenoid Piloted Manifold Valve – Eurofighter Typhoon Operating Fluid Operating Temperature Operating Pressure

Ouvrir le catalogue en page 25
FIAMC S.p.A. Presentation - 26

In-flight Refuelling Solenoid Piloted Manifold Valve – Eurofighter Typhoon

Ouvrir le catalogue en page 26
FIAMC S.p.A. Presentation - 27

Pressure Switches Pressure Switches to monitor hydraulic low pressure warning – they are installed on several circuits (hydraulic power generation, anti skid, in flight refuelling) on Tornado, EF2000, AM-X, UAVs

Ouvrir le catalogue en page 27
FIAMC S.p.A. Presentation - 28

Landing Gear Control Valve and Cockpit Control Lever Agusta-Westland AW101 Weight Connector Switches Operating Voltage

Ouvrir le catalogue en page 28
FIAMC S.p.A. Presentation - 29

Landing Gear Control Valve and Cockpit Control Lever Agusta-Westland AW101 Operating Fluid Operating Temperature Operating Pressure

Ouvrir le catalogue en page 29
FIAMC S.p.A. Presentation - 30

Sprag Lock Valve Agusta-Westland AW101 Operating Fluid Operating Temperature Operating Pressure Operating Voltage

Ouvrir le catalogue en page 30
FIAMC S.p.A. Presentation - 31

Tail Shut-Off Valve Agusta-Westland AW101 Operating Fluid Operating Temperature Operating Pressure

Ouvrir le catalogue en page 31
FIAMC S.p.A. Presentation - 32

Learjet 85 Rudder Bias Actuation System Rudder Bias Actuator Operating Temperature Operating Fluid Operating High Pressure Assy Weight Piston Load (extension) Piston Speed Operating Voltage (Valve) Rudder Bias Valve

Ouvrir le catalogue en page 32

Tous les catalogues et fiches techniques (PDF) FIMAC SPA