Ultrasonic Anemometer 2D
1 / 3Páginas

{{requestButtons}}

Extractos del catálogo

Ultrasonic Anemometer 2D - 1

Ultrasonic Anemometer 2D The Ultrasonic Anemometer 2D is designed to detect the horizontal components of wind velocity and wind direction as well as the virtual temperature in two dimensions. Digital / analogue The highest precision the measured values More than 35 Automatic heating of measurement values the sensor arms Range of application Due to its very short measurement intervals, the instrument is ideal for the inertia free measurement of gusts and peak values. The accuracy of the air temperature measurement (virtual temperature) surpasses that one of the classic method where the temperature transmitter is used in a weather and thermal radiation shield. The measured data are available as analogue signals or as a data telegram over a serial interface. The anemometer is equipped with an automatic heating for the instrument body as well as for the sensors so that the measuring results, in case of critical ambient temperatures, are not affected by ice, snow or rainfall. Mode of operation The Ultrasonic Anemometer 2D consists of 4 ultrasonic transformers, in pairs of 2 which are opposite each other at a distance of 200 mm. The two measurement paths thus formed are vertical to each other. The transformers act both as acoustic transmitters and acoustic receivers. The respective measurement paths and their measurement direction are selected via the electronic control. When a measurement starts, a sequence of 4 individual measurements is performed in all 4 directions of the measurement paths at maximum speed. The measurement directions (acoustic propagation directions) rotate clockwise, first from south to north, then from west to east, from north to south and finally from east to west. The mean values are formed from the 4 individual measurements of the path directions and used for further calculations. The time required for a measuring sequence is approx. 2.5 msec at +20 °C at the maximum measuring speed. Wind speed Measuring range 0 to 85 m/s, 0 to 165 kt (starting threshold: 0.01 m/s or 0.02 kt) 0.1 m/s, 0.2 kt (standard) 0.01 m/s, 0.02 kt (user defined) ± 0.1 m/s rms (< 5 m/s) ± 2 % rms (5 to 85 m/s)

Abrir la página 1 del catálogo
Ultrasonic Anemometer 2D - 2

MicroSteo Wind direction Measuring range 0 - 360° 1° 1° (standard) < 1° (user defined) ± 1° @ WS 1 to 60 m/s ± 2° @ WS 60 to 85 m/s Virtual temperature Measuring range Data output digital Interface Data values instant. values, average values, standard deviation Output range Status signals 1 per 10 msec up to 1 per 60 sec heating, Meas section error, Temperature of meas section Data output analog Wind speed Wind direction Voltage output Heated compontents sensor arms

Abrir la página 2 del catálogo
Ultrasonic Anemometer 2D - 3

Electr. connection ISO Quality Certified Company All specifications are subject to change without prior notice. © MicroStep-MIS. All rights reserved. www.microstep-mis.com

Abrir la página 3 del catálogo

Todos los catálogos y folletos técnicos MICROSTEP-MIS

  1. MMR-116

    3 Páginas

  2. RT1

    1 Páginas

  3. RHT175

    2 Páginas

  4. IMS4 MetReporter

    4 Páginas

  5. IMS4 RVR

    2 Páginas

  6. IMS4 ARWIS

    4 Páginas

  7. MM10

    2 Páginas

  8. IMS4 AWOS

    6 Páginas

  9. IMS4 Model Suite

    6 Páginas

  10. IMS LITE

    2 Páginas

  11. SWS-200

    2 Páginas

  12. IRS31 Pro

    1 Páginas

  13. IMS4 LLWAS

    4 Páginas

  14. IMS4 AWDSS

    4 Páginas

  15. IMS4 ARWIS 2014

    4 Páginas

  16. IMS CLDB

    8 Páginas

  17. MWD-30A

    1 Páginas

  18. IMS4 AMS 111 II

    4 Páginas

  19. SAWS 111

    2 Páginas

  20. RHT75

    1 Páginas

  21. PT100D

    1 Páginas