

Katalogauszüge

Small, simple, reliable – the Mini Line CLV503 / CLV505 / ICR803 The small giants amongst stationary bar code s
Katalog auf Seite 1 öffnen
Typical industries and applications 4 The devices of the Mini Line 5 Product selection guide 7 Readable code types and test codes 9 Dimensional drawings and reading field diagrams Dimensional drawings and reading field diagrams Ordering information devices and power supply 12 MINI LINE CLV503 / CLV505 / ICR803 | SICK
Katalog auf Seite 2 öffnen
Every millimetre counts when space is limited. Nevertheless, it is essential that the codes are reliably identified – and SICK offers products with its familiar dependability. Mini Line devices are hardly bigger than a USB plug and are easy to install in the tightest of spaces. Impressive qualities: small, easy and reliable – the Mini Line.
Katalog auf Seite 3 öffnen
Typical industries and applications The devices of the Mini Line are ideal when the need for reliable code reading is high but the space available is limited. Kiosk • Access control, e.g. −− Car parks −− Airports −− Ticket terminals −− Swimming pools/trade fairs/ events • Information terminals • Vending /recycling machines • Automatic lottery machines Ticket machine Access control at trade fair Access control at station Bar codes on test tubes Data Matrix codes on circuit boards Mounted on robot arms Pharmaceuticals • Clinical analyses Electronics industry • Circuit board identification...
Katalog auf Seite 4 öffnen
The devices of the Mini Line CLV503 and CLV505 devices use laser technology (line or grid scanners). They scan the barcode to be identified for light and dark bars. The reflected light is received by the laser scanner, whereby the light from the black bars is weaker than that from the white spaces. The signal received is digitized and then decoded. Allocation of the scanning line(s) for the bar code and conveyor system ICR803 devices use camera technology. They record an image of the object and search through this with image processing algorithms for 1D or 2D codes, which are then decoded....
Katalog auf Seite 5 öffnen
Device features Code reading While the target codes must be aligned for the CLV503/CKV505, the ICR803 reads omnidirectionally, i.e. in any orientation. Scanning frequency The CLV503 has a scanning frequency of 100 Hz. With its rotating mirror wheel, the CLV505 achieves a scanning frequency of 1,000 Hz and is thus also suitable for higher transport speeds of up to 5 m/s*). Image Processing Electrical connection The devices of the Mini Line are available with pre-assembled USB cables, while the ICR803 is also available with an RS 232 cable. If, in the case of the CLV503/CLV505, the RS 232...
Katalog auf Seite 6 öffnen
Product selection guide Device feature Readable code types (see also page 9) OCR Code reading Scanning frequency Electrical connections Image processing Technical data Ordering information USB and open wire ends for CLV503/CLV505 Dimensional drawings and reading field diagrams Readable code types/test codes Image Processing Compact ICR803 housing – no moving parts
Katalog auf Seite 7 öffnen
Technical data 2D Image Code Reader Visible green light (530 nm) Laser diode (wavelength) Laser class of device Light source Immunity to ambient light Usable aperture Scanning /decoder frequency Bar code print contrast (PCS) Beeper (buzzer) Clock reading pulse Digital input/command Manual trigger, command or Presentation Mode, hardware trigger via CDB405 Data interfaces USB keyboard wedge, USB serial, RS 232 USB keyboard wedge, USB serial, RS 232 TTL Digital switching inputs 1 x input for clock reading pulse Digital switching outputs Electrical connection 1.5 m cable with USB or open wire...
Katalog auf Seite 8 öffnen
Readable code types and test codes Chinese Post Korean Postal Authority code GS1 Databar Expanded Stacked GS1 Databar with Composite A/B Data Matrix Data Matrix
Katalog auf Seite 9 öffnen
Dimensional drawings and reading field diagrams CLV503 / CLV505 Dimensional drawing CLV503 43.3 10 20 Reading field diagram CLV503 320 Reading field diagram CLV505 Reading field height (mm) Reading field height (mm) 200
Katalog auf Seite 10 öffnen
Dimensional drawings and reading field diagrams ICR803 Dimensional drawing ICR803 Reading field diagram ICR803-A Reading field diagram ICR803-B
Katalog auf Seite 11 öffnen
Ordering information devices and power supply CLV503 Order no. Line scanner, front reading window, cable with open wire ends, RS 232 data interface Line scanner, front reading window, cable with USB plug, USB VCP/HID data interface Line scanner, front reading window, cable with open wire ends, RS 232 data interface Line scanner, front reading window, cable with USB plug, USB VCP/HID data interface Grid scanner, front reading window, cable with open wire ends, RS 232 data interface Grid scanner, front reading window, cable with USB plug, USB VCP/HID data interface 2D Image Code Reader...
Katalog auf Seite 12 öffnen
Accessories Cables and connectors Straight RS 232 TTL cable, 2.4 m length, external power supply (see page 12) necessary Straight RS 232 TTL cable, 2.4 m length, power supply on pin 9 Connection module CDB405-001 with integrated 24/5 V DC converter Straight RS 232 TTL cable, 2 m length, for connection of ICR803 to CDB405-001 RS 232 TTL spiral cable, external power supply device necessary (see page 12) RS 232 TTL spiral cable, power supply on pin 9 D-Sub plug-in connector insert, 15-pin HD receptacle strip (socket), manual solder connection D-Sub plug-in connector insert, 15-pin HD...
Katalog auf Seite 13 öffnen
Parameterisation of Mini Line devices takes place via configuration bar codes. Starting from the basic default settings, it is easy to change the most important parameter values to adapt to the application with the help of the configuration bar codes provided (see Quick Start for the particular An online tool is available at for the expanded configuration. This tool also provides the configuration in the form of configuration bar codes. It really is this easy: • Go to the graphic user interface at • Select the bar code for the desired configuration and • Scan the configuration bar code...
Katalog auf Seite 14 öffnenAlle Kataloge und technischen Broschüren von SICK SENSOR INTELLIGENCE
-
Sicherheitsschalter
20 Seiten
-
Automation light grids
8 Seiten
-
Opto-Electronic Protective Devices
32 Seiten
-
Encoders and Inclination Sensors
32 Seiten
-
Proximity Sensors
324 Seiten
-
Dust measuring devices
172 Seiten
-
Detection and Ranging Solutions
108 Seiten
-
Distance Sensors
404 Seiten
-
Vision
124 Seiten
-
Fluid Sensors
243 Seiten
-
Registration Sensors
276 Seiten
-
Magnetic Cylinder Sensors
172 Seiten
-
HANDHELDSCANNER
48 Seiten
-
IDENTIFIKATIONSLÖSUNGEN
24 Seiten
-
Encoder
788 Seiten
-
Lichttaster und Lichtschranken
932 Seiten
-
Optoelektronische Schutzeinrichtungen
694 Seiten
-
GMS800 Extraktive Gasanalysatoren
20 Seiten
-
DBS36/DBS50 Core Inkremental Encoder
44 Seiten
-
VPS Pro Profiling-Systeme
20 Seiten
-
REGISTRATION SENSORS
24 Seiten
-
CLV63x, CLV64x, CLV65x
102 Seiten
-
WTB16 Bluetooth®
135 Seiten
-
WE9LC-3_A71
3 Seiten
-
Top-Products from SICK
556 Seiten
-
FLOWSIC300 Ultrasonic Gas Flow Meter
177 Seiten
-
FLOWSIC300 Gas flow meters
12 Seiten
-
FLOWSIC500 Gas flow meters
16 Seiten
-
FLOWSIC600 Ultrasonic Gas Flow Meter
138 Seiten
-
FLOWSIC600 Gas Flow Meter
16 Seiten
-
ConVer
12 Seiten
-
GM32 In-situ gas analyzers
28 Seiten
-
GM901 Carbon Monoxide Gas Analyzers
12 Seiten
-
GM35 In-Situ IR Gas Analyzer
16 Seiten
-
WT100-2 with background suppression
46 Seiten
-
MERCEM300Z Mercury Monitoring System
12 Seiten
-
WT100-2 energetic
47 Seiten
-
G6 - Global Sensor
20 Seiten