Datacenter / Cooling System / Solutions NEW FRESH AIR FOR YOUR BYTES Minimize consumption / Maximize Efficacy

 Open the catalogue to page 1

Certifications and guarantee SAIFOR is a leading company in the design, manufacturing and integration of high-performance solutions for Data Centers and Control Rooms. All the company's products in this catalogue have been designed and manufactured in compliance with the following certifications: • UNE EN ISO 9001:2008 • UNE EN ISO 14001:2004 • (EC) Regulation No. 1221/2009 EMAS • Machinery directive 2006/42/EC • Low voltage directive 2006/95/EC • Electromagnetic compatibility directive 2004/108/EC The SAIFOR group designs and produces its products entirely in Barcelona (Spain). The production...

 Open the catalogue to page 2

Cooling / Systems / Solutions FEATURES Managing hotspots The design of this aisle type machine enables the installation of the cooling unit between the racks of a row, directly in areas where hotspots are generated. The air of the hot aisle, coming from the rear of the servers, is cooled and returned to the cold aisle, directly to the area where the inlets for cooling air of the servers. Applying airflow management strategies, it is possible to obtain great benefits in terms of energy efficiency and increasing cooling capacity and availability. This is especially appropriate for small and medium-sized...

 Open the catalogue to page 3

Cooling / Systems / Solutions MAIN FEATURES Interior design with optimised obstacle-free space to facilitate installation and maintenance from the front and rear of the machine. The connection box is compact and totally accessible, it includes built-in connectors for quick and safe connection. Free Cooling HDC+ has been designed to work with high water inlet temperatures (12- 20º C range). It is especially recommendable for installing in datacentres located in climatic areas that allow the design and installation of Freecooling cooling systems, drastically reducing Optionally it is available with...

 Open the catalogue to page 4

Cooling / Systems / Solutions MAIN COMPONENTS Control The machine core. Fitted with the latest control. Robust and reliable, the management unit handles and monitors all relevant parameters for precise temperature, humidity and consumption adjustments. It has dry contact external signals for general machine stoppage or emergency stops due to the detection of smoke/fire. Notification of alarms by email and proactive management of maintenance warnings for replacing, checking and cleaning components. Safety levels for user and administrator. 4.3” TFT touch screen display with 65000 colours and software...

 Open the catalogue to page 5

HDC+ Rack OPERATION SCHEMES OF THE HDC+ RANGE This type of configuration combines the HDC+ cooling unit and the IT equipment rack in the same enclosed space, isolated from outside. HDC+ Front Front air discharge, regulated by the EC cooling modules carried out directly towards the room in the case of hot aisles or towards the confined aisle in a cold aisle scenario. Cooling / Systems / Solutions As the servers are insulated from the outside, mixing outside air with interior air is avoided, with the resulting increased efficacy. This direct cooling increases energy savings as it reduces the amount...

 Open the catalogue to page 6

Cooling / Systems / Solutions IHDC+ Versions HDC+ Side This design guarantees maximum airflow and the greatest operational performance in each machine, thus contributing to improve operations and availability per m2 in the data centre. HDC+ 400 produces a maximum airflow of up to 10.350 m3/h, with a capacity of up to 71 kW, the values for HDC+ 300 being a maximum airflow of 7,050 m3/h, with a nominal capacity of up to 49.5 kW. The side distribution of air minimises mixtures of airflow and turbulences in the aisles. It also reduced losses due to deflection. As a whole, this achieves greater performance...

 Open the catalogue to page 7

Cooling / Systems / Solutions | HDC+ Front O HDC+ Front BASIC The HDC* Front version comes In 2 sizes. HDC* 300: up to 45.5 kW, HDC* 400: up to 65.5 kW. Both models include the following as standard: O Coolant fluid: water O EC fans with proportional speed adjustment. Independent. Rapid fitting, no tools needed. O 2-way proportional electronic valve. O High performance heat exchanger. O Hydraulic circuit discharge valve O Air bleeder. O Stainless steel tray for condensates. O Dual power supply for electrical redundancy (single-phase version). O Power supply: 230 Vac, 50/60 Hz O 2 blown air temperature...

 Open the catalogue to page 8

Cooling / Systems / Solutions HDC+ Side VERSIONS This version of the cooling unit moves the EC cooling modules to a position standing out in the row, in front of the racks. These cooling modules have outlets on the sides to blow air sideways, directly onto the front of the racks. HDC+ Side BASIC This system provides fresh air as needed by the installation, up to 6 racks. The HDC+ Front version comes in 2 sizes. HDC+ 300: up to 49.5 kW, HDC+ 400: up to 71.0 kW. Both models include the following as standard: Coolant fluid: water EC fans with proportional speed adjustment. Independent. Rapid fitting,...

 Open the catalogue to page 9

Cooling / Systems / Solutions | HDC+ Rack ■ VERSIONS O HDC+ Rack BASIC The HDC* Rack version is supplied in a single size -300 mm-, but with two air outlet options: HDC* 300 RACK 1 Outlet: up to 40 kW HDC* 300 RACK 2 Outlet: up to 49.5 kW Includes the following features: O Coolant fluid water O EC fans with proportional speed adjustment. Independent. Rapid fitting, no tools needed. O Hydraulic circuit discharge valve O Air bleeder. O Stainless steel tray for condensates. O Dual power supply for electrical redundancy (single-phase version). O Power supply: 230 Vac, 50/60 Hz O 2 blown air temperature...

 Open the catalogue to page 10

Cooling / Systems / Solutions HDC+ STEP BY STEP CONFIGURATION HDC+ Customised 1 OUTLET RACK VERSION 2 OUTLET RACK VERSION Customise your machine as needed TRIMS WITHOUT LEDS On the other hand, it significantly contributes to reducing operational costs, using only the energy strictly necessary for the operations being carried out. The modular design also implies adaptability and flexibility, in this manner, apart from standard configurations, detailed below, SAIFOR offers the possibility to configure each of the machines independently, in order to adapt to the cooling needs of each of the rooms...

 Open the catalogue to page 11

All SAIFOR catalogues and technical brochures

  1. ARCTIC 3.0

    33 Pages

    En
  2. WIDESTAR-saifor

    8 Pages

    En
  3. The company

    31 Pages

    En
  4. atc

    8 Pages

    En
  5. ARCTIC 3.0

    13 Pages

    En
  6. Arctic

    84 Pages

    En
  7. POWER

    24 Pages

    En
  8. DYNAMIC

    48 Pages

    En
  9. PRESTO

    16 Pages

    En
  10. cubo

    27 Pages

    En
  11. WIREX

    33 Pages

    En
  12. Ergo-noc

    16 Pages

    En
  13. Widestar 24/7

    8 Pages

    En
  14. VDS

    8 Pages

    En