45MG
12Pages

{{requestButtons}}

Catalog excerpts

45MG - 1

Your Vision, Our Future Ultrasonic Thickness Gage 45MG Ultrasonic Thickness Gage Simple, Rugged, and Reliable Operation Shown with optional waveform • Color transflective QVGA display • Dual element corrosion gaging • Precision thickness measurements • Rugged, designed for IP67

Open the catalog to page 1
45MG - 2

45MG Ultrasonic Thickness Gage Simple, Rugged, and Reliable Operation The 45MG advanced ultrasonic thickness gage is packed with standard measurement features and software options. This unique instrument is compatible with the complete range of Olympus dual element and single element thickness gage transducers, making it an all-in-one solution for virtually every thickness gage application. Built for Tough Environments • Rugged, designed for IP67 • Explosive atmosphere: tested using MIL-STD-810G, Method 511.5, Procedure I • Vibration tested using MIL-STD-810G, Method 514.6, Procedure I •...

Open the catalog to page 2
45MG - 3

Standard Features In its basic configuration the 45MG instrument is a simple and straightforward gage that requires minimal operator training to tackle most common thickness gaging applications. With additional optional software options and transducers, however, the 45MG thickness gage can become significantly more advanced and take on applications well beyond that of a typical entry-level gage. Furthermore, most options are available individually at the time of purchase or can be added in the future as your needs change. • Compatible with the full line of Olympus dual element transducers...

Open the catalog to page 3
45MG - 4

Thickness Measurements on Internally Corroded Metals Using Dual Element Transducers One of the major applications of the 45MG is measuring the remaining thickness of pipes, tubes, tanks, pressure vessels, ship hulls, and other structures affected by corrosion or erosion. Dual element transducers are most commonly used for these applications. • Automatic Probe Recognition for standard D79X series dual element transducers • Calibration doubling warning when echo doubling may occur during calibration • The echo-to-echo / THRU-COAT® technology option enables measurements on painted and coated...

Open the catalog to page 4
45MG - 5

Echo-to-Echo / THRU-COAT® Option Echo-to-Echo THRU-COAT Technology The gage displays the true metal thickness and ignores the thickness of the coating layer, using multiple back-wall echoes: Uses a single back-wall echo to measure true metal thickness. You can display the metal and coating thicknesses, each adjusted for their correct material sound velocities. There is no need to remove paint and coatings from surfaces. THRU‑COAT measurements use the D7906-SM, D7906‑RM, and D7908 dual element transducers. • Auto echo-to-echo • anual echo-to-echo (with A-scan option only) that enables: M --...

Open the catalog to page 5
45MG - 6

Dual Element Transducers for Corrosion Gaging All standard dual element transducers feature Automatic Probe Recognition, which automatically recalls a default V-path correction for each specific transducer. Transducer Item Number * Thickness range dependent on material, transducer type, surface conditions, and temperature. Full range may require Gain Adjust. ** Maximum temperature with intermittent contact only. Stainless steel cable available; consult Olympus for details. Transducers used with THRU-COAT® technology. Not certified to EN15317; these transducers are issued TP103 test...

Open the catalog to page 6
45MG - 7

Optional Data Logger and PC Interface The 45MG thickness gage has a full-featured internal bidirectional alphanumeric data logger that is designed to easily store and transfer thickness readings and waveform data. The data logger option includes the GageView™ interface program. Data Logger Option • Internal memory of 475,000 thickness readings or 20,000 waveforms with thickness readings • 32 character file name • 20 character ID# (TML#) • 6 file formats: Incremental, sequential, sequential with custom point, 2-D grid, boiler, and manual (from PC) GageView • Internal and removeable MicroSD...

Open the catalog to page 7
45MG - 8

Thickness Measurements on Plastics, Metals, Composites, Glass, Rubber, and Ceramics Using Single Element Transducers Single element transducers enable you to make accurate thickness measurements on metals, plastics, composites, glass, ceramics, and other materials. These transducers are available in a wide range of frequencies, diameters, and connector styles. In order to use a single element transducer with the 45MG gage, you must purchase either the Single Element software or the High Penetration software option. • Single Element software option can display measurements up to 0.001 mm...

Open the catalog to page 8
45MG - 9

Application Setup Recall Application Setup Recall simplifies making thickness measurements. Select any of the stored transducers and the 45MG gage recalls all relevant internal transducer parameters. Stored Standard Setups The 45MG gage includes 21 standard single element transducer setups for the most common applications. These default transducer setups can be used on wide variety of thickness applications. Material Sound Velocity Measurements The 45MG gage has the capability to make material sound velocity measurements. This standard feature is useful in applications where the speed of...

Open the catalog to page 9
45MG - 10

RBS-1 Immersion Tank The RBS-1 immersion tank is designed to simplify ultrasonic thickness measurements using immersion techniques.

Open the catalog to page 10
45MG - 11

Delay Line Transducers Microscan delay line transducers provide excellent performance on very thin materials, at elevated temperatures, or with applications that require a high degree of thickness resolution. * Exact range depends on material sound velocity, transducer frequency, part geometry, and surface condition. Replaceable Delay Lines Delay lines function as a protective buffer between the surface of the test piece and the transducer element. Additional Products Couplants Liquid couplant is almost always necessary to provide acoustic coupling between the transducer and the test piece....

Open the catalog to page 11
45MG - 12

Standard Package • 45MG digital ultrasonic thickness gage • AA alkaline batteries • 2-step test block and couplant • USB cable • User's manual on CD • Measurement features: Min./Max. mode, two alarm modes, Differential mode, B-scan, Reduction Rate, Programmable Lock Software Options • 45MG-SE (U8147022): Single Element option to use single element transducers with frequency range of 2.25 MHz to 30 MHz. • 45MG-HP (U8147023): Single Element High Penetration option to use single element transducers with frequency range of 0.5 MHz to 30 MHZ. • 45MG-EETC (U8147021): Echo-to-Echo and THRU-COAT® •...

Open the catalog to page 12

All Evident - Olympus Scientific Solutions catalogs and technical brochures

  1. IPLEX GX/GT

    8 Pages

  2. 35 RDC

    2 Pages

  3. OLYMPUS LC30

    2 Pages

  4. CIX100

    16 Pages

  5. MX63/MX63L

    20 Pages

  6. SWTLU-C

    4 Pages

  7. GX53

    20 Pages

  8. OLS5000

    42 Pages

  9. MagnaFORM

    2 Pages

  10. Portable XRD

    2 Pages

  11. 38DL PLUS

    12 Pages