DIAM4200 - 1

1 to 15 kVA IGBT controlled Sinusoidal Single-Phase Constant Current Regulator DIAM 4200 - 5 to 15 kVA COMPLIANCES ICAO: Annex 14 - Volume I, Aerodrome Design Manual Part 5 IEC: 61822 FAA: L-828/L-829 AC150/5345-10 APPLICATIONS DIAM4200 series CCRs are optimized static devices, controlled IGBT bridges, designed to maintain a constant, pre-displayed and adjustable output current independently of load or power supply fluctuations. These devices are specifically designed for visual aids supply, and particularly LED lights. CONSTITUTION Control electronics of the DIAM4200 is characterized by an innovative architecture linked by an internal CAN network, built around an AC power chopper with electronic boards using a powerful DSP processor. An USB front socket allows the connection of a portable computer for parameter setting, this setting being possible without live voltage. Remote control interface supports all the series networks, with or without redundancy, as well as universal multi wire interfaces. ADVANTAGES • Perfect sinusoidal output current. • No degradation of the power factor (PF near 1). • No fed back harmonics (THD near 0). • No tapping: automatic adaptation to the load • Space saving: ❖ Stackable (up to three units) for 1 to 2.5 KVA ❖ CCR's can be joined side by side, without gap ❖ Clearance at the back: 20cm minimum • Compatibility with all DIAM4XXX CCRs, same options and same control interfaces. • Easy maintenance: low number of spare parts, robust and simple architecture minimizing internal wiring, modularity of the power part by mean of 5kVA AC/AC units. • Friendly easy to use and very complete software tool (compatible with all DIAM4XXX), with oscilloscopic capability and data backup. Energy Technology srl Operating office: Via della Solidarieta 2/1 40056 Valsamoggia Loc. Crespellano - (BO) - Italy Ph: +39 051 66 56 611 - Fax: +39 051 66 56 677 KOCEM , a division of Energy Technology srl

Open the catalog to page 1
DIAM4200 - 2

OVERVIEW Each DIAM4200 is delivered into a metal frame with lifting rings. It includes 3 distinct parts: an "electronic" compartment, a "low voltage" compartment and a "high voltage" compartment. • The Electronic part includes an electronic board whose design uses last digital technologies; it is fixed at the front panel of the device. This front sheet supports the user interface delivering any useful information, and allowing all local or distant operations. Internal parts are accessible from the front or the top. • The Low voltage compartment includes all components involved in supplying...

Open the catalog to page 2
DIAM4200 - 3

www.ocem.com ocem@ocem.com USER INTERFACE DISPLAY FUNCTIONALITY - "Brightness state Bx" - "Output power Po" - "Output voltage Uo" Made up of a flat polyester keypad on the front plate, it includes a wide display of 16 x 140 pixel with screen saver, showing preferably on the upper line the installation state, warnings and parameters, and on the lower line the 4 keys definition, depending of the present menu. An USB front socket allows the connection of a lap-top computer, for parameters setting, also possible without live voltage. The display shows 2 lines of text allowing to monitor many...

Open the catalog to page 3
DIAM4200 - 4

Energy Technology srl Operating office: Via della Solidarieta 2/1 40056 Valsamoggia Loc. Crespellano - (BO) - Italy Ph: +39 051 66 56 611 - Fax: +39 051 66 56 677 {gOCEM , a division of Energy Technology srl

Open the catalog to page 4
DIAM4200 - 5

CUT-OUT AND EARTHING PLATE In option, the CCR can be equipped with an earthing cut-out plate using 4 jumpers which allows to make all maintenance and measurement operations on the loop, without unscrewing any load or earth connections: DIAM 4200 - 5 to 15 kVA Normal position: when the jumpers are in that position, Normal Position: when the jumPers are in that the CCR supplies normally the load. Position'the CCR suPP|ies normal|ythe load- Safety position: when the jumpers are in that position, load Safety position: when the jumpers are in that position, load and CCR are...

Open the catalog to page 5
DIAM4200 - 6

ORDERING CODE The DIAM4200 IGBT'S sinusoidal regulator is identified by a serial ordering number which indicates its type and particularity. If needed, add all useful precision and options. Example: D42-IEC-1-5-50-15-400-B21-530 = DIAM4200 compliant to IEC, 6.6A, 5 brightness, 50Hz, 15kVA, 400Vac, with a multiwire interface and Jbus serial network, with lightning arrestors on output terminals, Circuit breaker, EFD and LFD: Serie Type Class Style Freq. Output Power IEC type L-828 FAA Type (Options as described in L828 advisory are included) L-829 FAA Type (Options as described in L829...

Open the catalog to page 6

All OCEM - Airfield lighting catalogs and technical brochures

  1. LHI

    4 Pages

  2. LHP

    2 Pages

  3. AGLC

    6 Pages

  4. SCS

    7 Pages

  5. SCC

    2 Pages

  6. SO

    2 Pages

  7. VC30

    4 Pages

  8. TWSBF

    4 Pages

  9. TWOF

    4 Pages

  10. LETE

    4 Pages

  11. LETG

    4 Pages

  12. LIRH

    4 Pages

  13. AEOL

    4 Pages

  14. LERA

    4 Pages

  15. LIFL

    8 Pages

  16. LIRD

    4 Pages

  17. TDZF

    4 Pages

  18. FEAC

    4 Pages

  19. PAPI MULTI

    4 Pages

  20. LIRT

    4 Pages

  21. LERE

    4 Pages

  22. LIRC

    4 Pages

  23. LIRE

    4 Pages