B9600
6Pages

{{requestButtons}}

Catalog excerpts

B9600 - 1

Uninterruptable Power Supplies B9000FXS / B9600FXS Main Features TÜ Online Double Conversion Smart Online Functionality Internal Galvanic Isolation Transformer Front access With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS systems regarded as the most critical infrastructure device in the data centre. Interruptions to electrical supply can cost organisations in excess of £100,000 per hour in lost revenues and productivity. The innovative design of the B9000FXS and B9600FXS range makes it one of the most technologically advanced UPS of its kind developed, the FXS series delivers an advanced combination of low input current distortion, unity power factor input, high overall efficiency and maximum load protection ensuring ultimate power quality. This sophisticated arrangement of features make this series ideal for critical applications where reliability and high performance are fundamental. In addition, the FXS range comprises an IGBT input rectifier design with dual DSP (Digital Signal Processing) and μC (Micro Controller) technologies, which provides full digital control. The FXS configuration guarantees the high quality output required by loads needing a stable and clean source of power, whilst ensuring that auxiliary power supplies and processors are no longer single points of failure as with some other UPS Systems. VFI (Voltage & Frequency Independent) Online Double Conversion topology provides built-in inverter galvanic protection, completely isolating the output of the UPS from mains power problems and further protection is achieved via an integral output isolation transformer. This advanced design offers an extensive range of user benefits, delivering high efficiency without compromising load protection. > 3 Year Warranty > High Efficiency > Transformer Protection Magnus Power. Vision House, 41 Brunel Road. Churchfield Industrial Estate. St. Leonards on Sea East Sussex. TN38 9RT power being restored. Although the information and recommendations on this document are presented in good faith and believed to be correct, Magnus Power makes no representations or warranties as to the completeness or accuracy of the information. Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. in no event will Magnus Power be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information from this datasheet or the products to which the information refers. Magnus Power does not warrant the accuracy or timeliness of the materials on this datasheet and has no liability for any errors or omissions in the materials. Email: magnuspower.sales@akersolutions.com www.magnuspower.co.uk

Open the catalog to page 1
B9600 - 2

Online Double Conversion Ultimate protection for all loads from data centres to industrial applications, the B9000/B9600FXS incorporates Online Double Conversion or VFI (Voltage and Frequency Independent) topology. In Online Double Conversion mode the output voltage and frequency are constantly generated by the inverter and so are isolated from any input power disturbances, spikes, dips and outages. For maximum protection, the batteries are positioned in the conversion circuit to ensure there is no break or switching should the need arise for them to power the load. This technology allows...

Open the catalog to page 2
B9600 - 3

Enhanced Compatibility with Mains & Generators The B9000FXS/B9600FXS use an IGBT input rectifier design, encompassing an advanced PFC (Power Factor Correction), which can keep input current THDi (Total Harmonic Distortion of the input) at a level of less than 3% and an input power factor within 1% of unity, even when only small loads are applied. Main benefits for the user: > The installation of the UPS is simplified > Upstream electrical supplies and cables do not have to be heavily overrated to cope with high harmonic distortion > Standby generators can typically be downsized by 40% > Users...

Open the catalog to page 3
B9600 - 4

B9000 FXS 60 - 300 kVA / B9600 FXS 400 - 800kVA Technical Specification Transformer Based In keeping with tradition and time proven reliability the B9000FXS andB9600FXS include an output isolation transformer as standard. The benefit of eliminating the possibility of high DC voltage destroying a valuable data centre in the case of a failing semi conductor, certainly outweighs the small additional footprint required. The transformer increases the overload capabilities, step load performance and short circuit clearing capability and with the addition of a bypass isolation transformer (which...

Open the catalog to page 4
B9600 - 5

B9000 FXS 60 - 300 kVA Technical Specification POWER - KVA Dimensions WxDxH (mm) Weight (kg) Input/output connection Battery Hardwired (dual input) External, 300 cells INPUT Nominal voltage Voltage range Frequency Power factor Current distortion (THDi) OUTPUT Nominal voltage Frequency Voltage regulation PF acceptable without de-rating Overload capacity 220/380, 230/400, 240/415 VAC Three Phase -20%, +15% from nominal 50/60 Hz (45–65 Hz) 0.99 <3% 220/380, 230/400, 240/415 VAC Three Phase 50/60 Hz ±1% static; ± 5% dynamic 100% load change, <20 ms recovery time Lagging to 0.9 leading 101–125%...

Open the catalog to page 5
B9600 - 6

B9600 FXS 400 - 800 kVA Technical Specification POWER - KVA Dimensions WxDxH (mm) Weight (kg) Input/output connection Hardwired (dual input) Nominal voltage Voltage range Power factor Current distortion (THDi) OUTPUT Nominal voltage Voltage regulation ±1% static; ± 5% dynamic 100% load change, <20 ms recovery time PF acceptable without de-rating Overload capacity 101–125% for 10 min (on-line); 126–150% for 1 min (on-line); 1000% for 1 cycle (bypass) Efficiency - Online Double Conversion Eco-mode - Smart Online OPTIONS Parallel capacity/redundancy; External bypass; Battery thermal probe; Top...

Open the catalog to page 6

All MAGNUS POWER catalogs and technical brochures

  1. E2001.e

    2 Pages

  2. B8000

    4 Pages

  3. B400

    2 Pages

  4. B500R

    3 Pages

  5. B200

    1 Pages

  6. B9000

    6 Pages

  7. B500

    3 Pages

  8. B60

    1 Pages

  9. ME3

    4 Pages

  10. LP3

    1 Pages

  11. ME1

    4 Pages

  12. LP1

    1 Pages

  13. LF3-400

    1 Pages

  14. LF1-400

    1 Pages