GMS 022P Main Features Frequency    Hz    50 Power factor    cos ^    0.8 Power Rating Ratings definition (According to standard ISO8528 1:2005) PRP - Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power. LTP - Limited-Time running Power: It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers.No overload capability is available.

 Open the catalog to page 1

Engine specifications Engine manufacturer Model [50Hz] Exhaust emission level Engine cooling system Nr. of cylinder and disposition Displacement Aspiration Speed governor Prime gross power PRP Maximum gross power LTP Oil capacity Coolant capacity Fuel Specific fuel consumption @ 75% Specific fuel consumption @ PRP Starting system Starting engine capability Electric circuit Engine Equipment Standards The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1 Fuel system Rotary type pump Lube oil system Wet steel sump with filler...

 Open the catalog to page 2

Alternator Specifications Brand Model Voltage Frequency Power factor Poles Type Voltage regulation system Standard AVR Voltage tolerance Efficiency @ 75% load Class IP protection Mechanical structure Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups. Voltage regulator Voltage regulation with DSR. The digital DSR controls the range of voltage, avoiding any possible trouble that can be made by unskilled personnel. The voltage accuracy is ±1% in static condition with any power factor and with speed variation between 5% and...

 Open the catalog to page 3

Genset equipment BASE FRAME MADE OF WELDER STEEL PROFILE, COMPLETE WITH: • Anti-vibration mountings properly sized • Welded support legs PLASTIC FUEL TANK WITH THE FOLLOWING COMPONENT: • Filler neck • Air breather (ventilation pipe) • Minimum fuel level sensor ENGINE COMPLETE WITH: • Battery • Liquids (no fuel) • Oil drainin pipe with cap CANOPY: • Soundproof canopy made up of modular panels, realized with zinced steel as treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a full weatherproof enclosure. • Easy access to the genset for maintenance purposes...

 Open the catalog to page 4

Battery capacity MAX current Circuit breaker Dimensional data Length (L) Width (W) Height (H) Dry weight Fuel tank capacity Fuel consumption @ 75% PRP Fuel consumption @ 100% PRP Running time @ 75% PRP Running time @ 100% PRP Noise level Guaranteed noise level (LWA)    dB(A)    87 Noise pressure level @ 7    dB(A)    58 Installation data Data Current

 Open the catalog to page 5

ACP - Automatic control panel Mounted on the genset, complete with digital control unit for monitoring, control and protection of the generating set, protected through door with lockable handle. DIGITAL INSTRUMENTATION • Generating set voltage (3 phases). • Mains voltage. • Generating set frequency. • Generating set current (3 phases). • Battery voltage. • Power (kVA - kW - kVAr). • Power factor Cos $. • Hours-counter. • Engine speed r.p.m. • Fuel level (%). • Engine temperature (depending on model) COMMANDS AND OTHERS • Four operation modes: OFF - Manual starting - Automatic starting - Automatic...

 Open the catalog to page 6

All Generac Mobile Products catalogs and technical brochures

  1. CUBE+ Next

    2 Pages

    En
  2. Hydro Power Box

    2 Pages

    En
  3. Cube +

    2 Pages

    En
  4. VT-Hybrid

    2 Pages

    En
  5. GMS - 30P

    6 Pages

    En
  6. GMS-015Y

    8 Pages

    En
  7. GMS-015P

    8 Pages

    En
  8. GMS-010P

    8 Pages

    En